Overview
Vantage's LCAP Series Commercial Enclosures ship with pre-
configured modular solutions for commercial, architectural load
dimming and switching. The pre-configured designs save time in
Design Center and installing.
The UL listed LCAP44A panels are adaptable to spaces that have
mixed 0-10V, and PWM loads and HV relay loads via Vantage's
LVOS-0-10-PWM station. LCAP44A connects to any controller
over the local network for easy connection and scalability.
Solution 1 – Parent-level Enclosure Models
Main Enclosure
LCAP44
44" Architectural Enclosure
Optional Parts
VA-RRU-1-120V
Emergency Shunt Relay - 120V
VA-RRU-1-277V
Emergency Shunt Relay - 277V
VA-EPC-DFS-120V
Emergency Lighting Surface Mount Switch 120V
VA-EPC-DFS-277V
Emergency Lighting Surface Mount Switch 277V
Specifications
LCAP44A
Cabinet Dimensions
44.5" x 24" x 4.575" / 113cm x 61cm x 11.6cm
HWD
Door Dimensions HWD
44.5" x 24" x 0.75" / 113cm x 61cm x 2cm
Panel Insert HWD
42" x 21" x 4.175" / 106.7cm x 53.3cm x 10.6cm
Weight Enclosure
Weight Door
Weight Panel Insert
Number of LVOS-0-10-PWM* stations
Analog, 0-10DC/LV — Max. Outputs
PWM, LV — Max. Outputs
HV Relay 120-277 VAC — Max. Outputs
Line Feeds (breakers) required
Enclosure Finish
Door Finish
Cover
HV Wire
copper wire, min of 80°C/176°F insulation
Ventilation
Ambient Operating Temp.
Ambient Operating Humidity
UL, CUL, and CE listed
* See these install sheets for important information:
Low Voltage Output Station Lighting_LVOS-0-10-PWM-1
LCAP Enclosure Designs
LCAP Series Enclosure Facts.
Enclosures must be populated from left to right and top down.
o Blank positions cannot be left between lighting modules in
Design Center setup.
Enclosures are pre-configured and wired (to the extent
possible)
using
specific
components. Installed components are dependent on the
enclosure design.
o Components using high voltage wiring.
 Mixed high voltage wiring.
o Components using low voltage control signal wiring.
o Components using low voltage communication wiring.
o Components
using
connections made inside the enclosure.
The enclosure uses built-in barriers to separate high and low
voltage wiring.
o Some designs include the barrier while other designs
require the barrier be added by the designer.
o High
voltage
barriers
120V/240V/277V load modules.
LCAP44A Enclosures only contain LVOS-0-10-PWM stations.
©Vantage,
9/2/2015 / IS-00709-B
Description
Description
Specifications
41 lbs / 18.6 kg
20.7 lbs / 9.39 kg
23 lbs / 10.43 kg
Up to 6
Up to 24
Up to 24
Up to 24
1 and Up
Galvanized Steel
Black - Powder Coated
vented, hinged
maintained 36" front clearance
0-40°C / 32-104°F
5-95% non-condensing
yes
combinations
of
the
following
high
voltage
and
low
voltage
may
be
installed
between
Commercial Power Enclosure Solutions — MODEL: LCAP44A
I N S T A L L A T I O N
Commercial Power Enclosure Solutions — MODEL: LCAP44A
Enclosure Features / Parts
1.
Enclosure can.
2. Panel Insert
3. Ground terminals.
4. Wiring terminal blocks (see close-up next page).
a. Internal side pre-wired.
b. External side wired in field.
5. Up to 6, LVOS-0-10-PWM stations.
6. LV section.
7. Enclosure cover with hinged/vented door allowing easy access
when servicing and proper ventilation for convection cooling
process.
LCAP44A Panel Optional Construction Parts
EMR. SWITCH
POE SWITCH
VA-RRU-1-12OV
COM-POE-SWITCH
Installation / Enclosure Mounting Instructions
Installation of Vantage LCAP products should be performed or
supervised by the Vantage factory and/or a Certified Vantage
Installer. Installation and maintenance of high voltage devices
should only be performed by licensed, qualified, and competent
personnel having appropriate training and experience.
CAUTION:
Turn Breakers OFF and Check that no Power is ON at
the AC Terminal Boards when working in the
enclosure or working on lighting fixtures connected
to the Module's Loads, etc. Do not allow trimmed wire
cuttings to fall into enclosure components as they
may cause damage when power is restored. Damage
from this type of short will void the warranty.
Do not mount enclosures in attics, garages, or crawlspaces,
unless room is properly conditioned to conform to ambient
room temperature and humidity requirements.
Mount enclosure a minimum of 18" from ceiling or floor.
National Electrical Code requires a minimum frontal clearance
of 36" for the enclosure.
Use screws provide for mounting.
General Wiring
Drill proper size holes in can for running wires in
and out of the enclosure. Separate high and low
voltage wire run channels. All wire runs in and out
of the enclosure should be secured using 2-screw
connectors or equivalent as shown at the right
Proper conduit or equivalent wire channels should
be used according to local codes and regulations.
V A N T A G E I N S T A L L G U I D E S
EMR. SWITCH
VA-EPC-DFS-12OV
(277V)
(277V)
Please see install sheets for
emergency switch applications.
.
page 1 of 2

Advertisement

loading

Summary of Contents for Vantage Hearth LCAP44

  • Page 1 7. Enclosure cover with hinged/vented door allowing easy access when servicing and proper ventilation for convection cooling Solution 1 – Parent-level Enclosure Models process. Main Enclosure Description LCAP44 44” Architectural Enclosure Optional Parts Description VA-RRU-1-120V Emergency Shunt Relay - 120V...