Download Print this page

ORing Industrial Networking Corp. IDS-181A Quick Installation Manual

Industrial device server

Advertisement

Quick Links

ORing Industrial Networking Corp.
Device
Device
Server
Server
Q
I
uick
nstallation
Introduction
IDS-181A/141A
is an innovative secure 8/4 port RS-232 to 1 port LAN serial to Ethernet
device server featuring the standard features of device server, such like versatile
operation modes: Virtual Com, Serial Tunnel, TCP Server, TCP Client, UDP, Ethernet
mode. In addition, the Windows untility, DS-Tool, could configure multiple devices and
set up the mappings of Virtual Com. The features of NAT Router Pass Through, and
DDNS make it more convenient for administrators to configure ORing's device servers
through NAT router from different IP domains or Internet via modem remotely. On the
other hand,
IDS-181A/141A
can simultaneously transfer data up to 5 redundant host
PCs to aovid Ethernet connection breakdown or any host PC fails. Further,
181A 141A
/
features HTTPS, SSH, and SSL encryption to assure the security of critical
data transmission.
IDS-181A/141A
provides dual redundant power inputs, 12~48 VDC on terminal block
and DC power jack to guarantee a non-stop operation. With wide operating temperature,
o
-40~70 C, and rugged IP-30 housing design,
IDS-181A/141A
.
industrial environment Therefore
IDS-181A/141A
demand of secure serial to Ethernet critical data communication
Features
Versatile Modes: Virtual Com, Serial Tunnel, TCP Server, TCP Client, and UDP
modes
Multiple host devices: 5 host devices: Virtual COM, TCP Server, TCP Client mode;
4 host devices: UDP
NAT-pass through: user can manage IDS-181A/141A through NAT router
Security: SSL data encryption; secured management by HTTPS and SSH: IP
Access: IP Black List
WAN Connection: PPPoE authetication
Update DNS Hostname: DDNS
Event Warning by Syslog, Email, SNMP trap, and Relay
Configurable by Web-based and Windows utility (DS-Tool)
Various Windows O.S. supported: Windows NT/2000/XP/ 2003/VISTA/Window7(32-
bit)
Power Connection Guide
PWR-2
1A@24V
PWR-1
DC12-48V
V2+ V2-
V1+ V1-
V+
V-
Power
V-
V+
Supply
12-48 VDC
Warning
Device
+24V
GND
Power
Supply
Q I G
IDS-181A/141A Series
IDS-181A/141A
G
uide
Specifications
ORing Serial Media
Converter Model
Feature
10/100 Base-T(X) Ports in RJ45
Auto MDI/MDIX
Serial Ports
IDS-
RS-232 Serial port number
Connector
Operation Mode
Serial Baud Rate
could operate in the harsh
Data Bits
is the best solution to the high
Parity
.
Stop Bits
RS-232
Flow Control
Network Features
Network Protocols
LED indicators
LED indicator
LED indicators
Power indicator
LED indicators
Fault LED
10/100Base-TX RJ45 port
indicator
Serial TX / RX LEDs
Power
Redundant Input power
Power consumption(Typ.)
Overload current protection
Reverse polarity protection
Physical Characteristic
Enclosure
Dimension (W x D x H)
Weight (g)
Environmental
G
Storage Temperature
Frame Ground
Operating Temperature
Operating Humidity
Regulatory approvals
EMI
Power
Adapter
EMS
12-48 VDC
Shock
Free Fall
Vibration
Safety
Warranty
IDS-181A
IDS-141A
1
1
8
4
DB62 Female (provide DB62 to 8 ports DB9 cable)
DB62 Female (provide DB62 to 4 ports DB9 cable)
RS-232
110 bps to 115.2 Kbps
5, 6, 7, 8
odd, even, none, mark, space
1, 1.5, 2
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
XON/XOFF, RTS/CTS, DTR/DSR
ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS, SNMP V1/V2c, HTTPS, SMTP, PPPoE, DDNS, SSL
PWR 1(2) / Ready :
Green On : Power is on and CPU is booting up.
Amber on: Ethernet link down; PWR 1or PWR 2 fails
(Fault LED for PWR fails is disable as default , but could be set up on WEB UI)
Green for port Link/Act. Amber for 100Mbps.
Green Blinking: Serial port is transmitting data (TX/RX)
Dual DC inputs. 12-48VDC on 6 pin terminal block and power jack
4.5 Watts
3.7 Watts
Present
Present on terminal block
IP-30
94.9mm x 26.1mm x 144.3mm (3.74x1.03x5.68 inch)
358 g
355 g
-40 to 85 C (-40 to 185 F)
o
o
-40 to 70 C (-40 to 158 F)
o
o
5% to 95% Non-condensing
FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
IEC60068-2-27
IEC60068-2-32
IEC60068-2-6
EN60950-1
5 years
PRINTED ON RECYCLED PAPER
Industrial Device Server
Practical Operation
In practical operation of serial device servers, Windows utility (DS-Tool) is supported. This
utility is very helpful for you to manage and monitor all of industrial device servers on the
industrial network.
Multiple Host PCs
NAT Router Pass Through
PPPoE and DDNS
SSL Encryption
TCP Server/Client Mode
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
Website: www.oring-networking.com
FAX: +886-2-2218-1014
E-mail: support@oring-networking.com
Quick Installation Guide
Version 1.0

Advertisement

loading
Need help?

Need help?

Do you have a question about the IDS-181A and is the answer not in the manual?

Questions and answers

Summary of Contents for ORing Industrial Networking Corp. IDS-181A

  • Page 1 Power indicator Green On : Power is on and CPU is booting up. NAT-pass through: user can manage IDS-181A/141A through NAT router Security: SSL data encryption; secured management by HTTPS and SSH: IP Amber on: Ethernet link down; PWR 1or PWR 2 fails...
  • Page 2 X 1, N.C. device server with 4xRS-232 and IDS-141A X 1, X 1, X 1, 1x10/100Base-T(X), DB62 connector RS 232 mode act as DTE 10/100M 10/100M 100MBbps Indicator (Amber) Q I G IDS-181A/141A Series PRINTED ON RECYCLED PAPER Quick Installation Guide...

This manual is also suitable for:

Ids-141a