Reference Drawing Air Pressure Regulator Knob Air Flow Valve Air Inlet Valve Abrasive Flow Valve Foot Switch Valve Footpedal Water Seperator Air Pressure Regulator Gauge Union Nut Blast Hose Pressure Pot Closure Lever Air Inlet Valve Quick Disconnect Blast Nozzle...
Do not blast materials that may produce equipment. Breathing dust from silica sand may cause silicosis, a fatal lung d isease. We recommend 10/4/2010 (9:18 AM) 2034 - 1 - Safety v4.05...
SET incoming air pressure from air compressor between 80psi to 90psi. Set blasting pressure regulator on the pot to desired blasting pressure, normally between 25 psi - 35 psi. 10/4/2010 (9:18 AM) 2034 - 1 - Safety v4.05...
Page 8
If there are any external or internal damages to the 2.2 Delivery & Unpacking Instructions equipment it must be noted on the carrier’s bill of lading. Contact Rayzist customer service at 1-800- ! WARNING 729-9478 immediately to process a damage claim.
Page 9
(E). Connect the long hose to the quick disconnect fitting located between water separator (G) and the air inlet valve (C). 2.8 Dust Bag Installation 2.5 Removal from Pallet. 10/4/2010 (9:18 AM) 2034 - 2 - Setup v4.05...
Exhausting through a long vent pipe may require an additional exhaust fan installed at the point the vent exits the building. 10/4/2010 (9:18 AM) 2034 - 2 - Setup v4.05...
Free Air CFM @ 90 PSI: 5.7 Locate the Operation Manual to continue. Free Air CFM @ 135 PSI: 4.9 Volts 60 Hz: 115/230 Amps: 15/7.5 Tank Capacity (Gal): 20 2. Water Trap 3. Air hose 10/4/2010 (9:18 AM) 2034 - 2 - Setup v4.05...
Page 13
Air Inlet Valve (C) is in the “OFF” position (horizontal) and the air compressor has been set up according to instructions found in the Rayzist setup guide. Connect the compressor air hose to the Air 3.2.2...
Page 14
(C) and try again. If for some reason you cannot get the pressure pot closure cap ! NOTICE to seal, call Rayzist and ask for technical help. 3.4 Adjusting Blasting Pressure. The air pressure regulator (A) sets the blasting...
Page 15
! NOTICE through the arm holes of the cabinet creating a hazardous condition of dust in the air. 10/4/2010 (9:19 AM) 2034 - 3 - Operation v4.05...
36 to 40 Inches long. Bags are available through airborne dusts. Rayzist or your local plastic bag company. 4.1 Daily Maintenance ! NOTICE Normally water drains from the water 4.1.1...
Page 18
! NOTICE off the Air Flow Valve (B). Press the Foot Pedal (F) until the bucket is full or the pressure pot is empty. Put worn abrasive in plastic bag and 10/4/2010 (9:19 AM) 2034 - 4 - Maintenance v4.05...
Electrical Connection Box Black Black Motor Leads 22mm Ground Lever Action Black Double Pole 10A Switch Contact Black Black Green w/ Yellow White Copper Enclosed Halogen Light Fixture 100w Lamp 220 VAC 10/4/2010 (9:19 AM) 2034 - 4 - Maintenance v4.05...