AM-DPR – Dual Formatted Proximity Credential Reader
Linear Model AM-DPR Proximity Reader is designed for use with Access Control Systems. The AM-DPR
is easy to install, rugged, rated for extreme weather, and vandal resistant.
MULLION INSTALLATION DIAGRAM
3/4" Diameter through
hole for cable and
buzzer.
1.0"
1.3"
.600
¿
¿
.300
¿ ¿
Label
Insert
WIRING CONNECTIONS
WIRE COLOR
RED
BLACK
YELLOW
BLUE
ORANGE
BROWN
GREEN
WHITE
VIOLET
GRAY
( 1 ) C o n n e c t t o G R O U N D t o a c t i v a t e
PARTS SUPPLIED:
Reader
Installation Instructions
2, #6 Mounting Screws
Snap-In Label
3322270 7481
SPECIFICATIONS AND INSTALLATION INSTRUCTIONS
Wall Surface
Use appropriate
#6 Fastener
1.60
¿
¿
Cable
(2 ft. supplied)
LED
Label Tabs
Insert Here
Buzzer
¿
Proximity Reader
Model AM-DPR
FUNCTION
5-14 VDC +
GROUND ---
BUZZER INPUT (1)
HOLD
GREEN LED INPUT (1)
RED LED INPUT (1)
WIEGAND DATA-0
WIEGAND DATA-1
NOT USED
NOT USED
1. I f mounting the unit outdoors, especially on a rough
surface like masonry, we recommend that you seal the
reader with silicone caulking.
2. D rill a hole for the field wiring. Remove label insert from
reader. Using the reader as a template, mark the location
of the two mounting holes. Drill two 1/8" pilot holes for the
mounting screws.
3. R un field wiring to reader location and feed through
cable hole.
4. S plice the reader cable to field wiring.
5. A ttach the reader to the surface using the two machine
screws provided. These may be replaced with tamper
proof screws (customer supplied).
6. S nap the label insert into front of reader to cover screws.
SPECIFICATIONS:
POWER REQUIREMENTS
5-14 VDC, 150 mA Max.
CONTROL INPUTS
Red LED, Green LED and Buzzer
WIEGAND OUTPUT
Maximum Distance:
500 ft. - 5 or 6 conductor 20 gauge shielded cable
ENVIRONMENT
Reader, Key Tags and Cards
Ambient Temperature: -40° to +70°C (-40° to +158°F)
Humidity: 0 to 95% (non-condensing)
LINEAR CREDENTIAL COMPATIBILITY
AM-PT: 26 bit Wiegand Tag in Linear Format
AM-PC: 26 bit Wiegand Card in Linear Format
AM-HPC: 26 bit Wiegand Card in HID Compatible Format
AM-HPT: 26 bit Wiegand Tag in HID Compatible Format
TRANS PROX Family: Integrated Transmitter and 26 bit
Wiegand Proximity – in Linear and HID Compatibility format
Note: Linear is not responsible nor guarantees operation of
AM-DPR with any other credentials.
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
HID is a trademark of HID Global Corp.
www.linearcorp.com

Advertisement

loading

Summary of Contents for Linear AM-DPR

  • Page 1 AM-DPR – Dual Formatted Proximity Credential Reader SPECIFICATIONS AND INSTALLATION INSTRUCTIONS Linear Model AM-DPR Proximity Reader is designed for use with Access Control Systems. The AM-DPR is easy to install, rugged, rated for extreme weather, and vandal resistant. 1. I f mounting the unit outdoors, especially on a rough MULLION INSTALLATION DIAGRAM surface like masonry, we recommend that you seal the 3/4” Diameter through reader with silicone caulking. hole for cable and Wall Surface 2. D rill a hole for the field wiring. Remove label insert from buzzer. reader. Using the reader as a template, mark the location Use appropriate of the two mounting holes. Drill two 1/8” pilot holes for the #6 Fastener mounting screws.
  • Page 2 LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details. INSTRUCTION TO THE USER FCC ID: NNHDTR1 “This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.” This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this...