INSTALLATION INSTRUCTIONS
F Series Floodlight
FIXTURE WIRING
This fixture must be wired in accordance
with the NEC and applicable local codes.
WARNING: Proper grounding is
required to insure personal safety.
Connect the green or bare copper fixture-
ground lead to a suitable ground
connector. Use approved connectors for
all electrical connections.
© 2016 Philips Lighting Holding B.V. All rights reserved.
www.philips.com/luminaires
Part Number 443561002550 Rev. F
Page 3 of 7
STEP 6
Unscrew
and
remove
connector nut from cable connector on
side
of
ballast
mastfitter,
FIGURE 5). Remove the rubber
grommet from cable connector body.
Slide cable connector nut up the S.O.
cord, then slide the rubber grommet
approximately 3" up the S.O. cord.
Insert S.O. cord into cable connector
body, then attach and securely tighten
the cable connector nut to
lbs.
STEP 7
Remove inspection plate and gasket
from back of mastfitter by removing
the two screws (See FIGURE 5).
Mount fixture/ballast assembly to 2-
3/8" OD vertical pipe tenon (by others)
after pushing branch circuit lead wires
(by others) through the mastfitter and
out inspection plate opening. Service
may also be made by removing the
1/2" pipe plug from the mastfitter and
attaching a proper watertight connector
(by others), and then inserting an S.O.
cord with branch circuit lead wires (by
others). Tighten the two 3/8" square
head set screws on the side of the
mastfitter against the pipe tenon to 8
ft-lbs.