Green TMR-234 Instruction Manual

Green TMR-234 Instruction Manual

Multi - function digital timer

Advertisement

Quick Links

DIMENSIONS
Front view
48
GREEN
TMR - 234
RUN
RLY
TIMER
SET VALUE
SET
MENU

SPECIFICATIONS

Range
Present Time Display
Set Time Display
Start , Reset , Gate
Output
Relay contact rating
(Resistive load)
Mechanical life of relay
Electrical life of relay
User programming
Timer direction
Mounting
Relay make
Function
Relay ON
Indication
Timer running Indication
Power consumption
Memory Retention
Range Selection
Supply voltage
Operating frequency
Weight
Dimension ( L x W x D )
Ambient humidity
Ambient temperature
Storage temperature
In the pack
INSTRUCTION MANUAL
Side View
75
GREEN
TMR - 234
!
RLY - 1A
100 - 240V AC , 50/60 HZ
P
N
COM
NO
C
NC
1
2
3
4
5
6
13
14
15
16
17
18
START
RESET
GATE
7
8
9
10
11
12
NO
C
NC
RLY - 1B
GREEN MICROELECTRONICS INDIA PVT. LTD.
www.greenelectronics.in
MADE IN INDIA
0.01 Second - 99.9 Hours
Four digits, 0.4 Inch Red seven segment LED
Four digits, 0.28 Inch Green seven segment LED
External
2 c / o
5 A @ 230 VAC
/ 30 VDC
10 million operation
100,000 operation
4 Keys & Display
Up / Down
Door mountable
Omron
On - Delay , Interval , Cyclic , Signal On Delay , Signal Off Delay,Start-Stop
Red LED
Flashing Red LED
1.5 VA
Selectable
Program
100 - 240 VAC
50 / 60 Hz
160 grams
48 x 48 x 85
35 to 85 % RH
-10 to 55 c
-25 to 65 c
Timer, 2 Mounting Clamps and instruction manual
TMR-234
TMR-234
Multi - function Digital Timer

INTRODUCTION

Thank you very much for purchasing this GREEN product
TMR - 234. Please read the instruction manual carefully for
the full usage of this product
The Timer has passed various quality tests before despatch.
Please check however, at the time of arrival, its model code
and its appearance and ensure that all the contents are provided
and there are no faults, damage etc, to the timer. Please also
ensure that the model code ,which is labeled on the timer,
is identical to the one you ordered.
NOTE
1. Our company shall not be liable for any damages, as described
below, caused to both any users and third parties
a) Damages caused by the result of operation of the product.
b) Damages caused by any defects in the product which are
unpredictable for us.
2. The content in this manual are subject to change without any
notice. If you have any suggestion on the matter,
Please do not hesitate to contact us.
WIRING DIAGRAM & I/O FUNCTIONS
START
P
1
13
7
100 - 240V AC
50/60 HZ
RESET
N
2
14
8
GATE
COM
3
15
9
NO
4
16
10
C
C
5
17
11
RLY - 1A
NC
6
18
12
GREEN MICROELECTRONICS INDIA PVT. LTD.
green@greenelectronics.in |
COMPONENTS FOR AUTOMATION

PRECAUTION FOR SAFE USE

(1) Use and store the Timer within the specified
ambient temperature and humidity ranges.
(2) Do not use the product in location subject to vibrations
or shocks. Using the product in such location over a long
period may result in damage due to stress.
(3) Do not use the product in locations subject to dust,
corrosive gases, or direct sunlight
(4) Separate the input signal devices, input signal cables
and the product from the source of noise or high - tension
.
cables producing noise
(5) The supplied power voltage and load must be within the
rated and specified ranges.
.
(6) Do not use where the water or oil splatter on the Timer
(7) Install a switch or circuit breaker that allows the operator
to immediately turn off the power
START
TO START THE TIMER
RESET
TO STOP THE TIMER OR
THE RELAY
TO PAUSE THE TIMER AT RUN CONDITON
GATE
AND MAINTAINED THE STATUS OF RELAY
RUN LED
LED FLASHES WHEN TIMER IN RUNNING
NO
LED WILL ON WHEN TIMER IN PAUSE
LED WILL OFF WHEN TIMER IN STOP
RLY LED
LED WILL ON WHEN RELAY TURNED ON
RLY - 1B
RLY-1A,1B
MAKES OUTPUT IN ACCORDANCE
NC
WITH THE TIMER TYPE SETTING
MANUFACTURER
www.greenelectronics.in
| 0422-2590288
TURN OFF
version 1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMR-234 and is the answer not in the manual?

Questions and answers

Summary of Contents for Green TMR-234

  • Page 1 Front view Side View INTRODUCTION PRECAUTION FOR SAFE USE Thank you very much for purchasing this GREEN product TMR - 234. Please read the instruction manual carefully for (1) Use and store the Timer within the specified GREEN TMR - 234 the full usage of this product ambient temperature and humidity ranges.
  • Page 2 SEE NOTE BEFORE INITIAL / SETVALUE SETTINGS RANGE SETING SETVALUE SETTING INITIAL SETTING PRESS FOR 2 SEC PRESS MENU FOR 2 SEC WHEN TIMER IN STOP CONDITION EXCEPT CYCLIC TIMER TYPE EXCEPT CYCLIC & START - STOP TIMER TYPES SELECT THE TIMER TYPE USING KEYS SELECT THE OFF-TIMER RANGE SELECT THE TIME (SETVALUE)

Table of Contents