Safety Warnings

• This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE wiring
Regulations and should be installed in accordance with local Building Regulations and is for Domestic
indoor ceiling use only and not suitable for a Bathroom location.
• The light fitting should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp miniature
circuit breaker).
• This product is a Class I fitting and must be Earthed.
• If in doubt we recommend you contact a qualified electrician. Before installing your light fitting always
switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker
before commencing installation, and ensure that no one else has access that would enable the supply to
be inadvertently reconnected.
• Never fit bulbs of a higher wattage or of a type other than those specified on the label as this may cause
overheating and damage the fitting.
• These product contains glass parts – be careful during handling and maintenance to avoid breakage.
• If any modification is made it will invalidate the warranty and may render the product unsafe.

Care Information

Allow 10 minutes to cool before replacing, adjusting or cleaning.
Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.

Assembly/ User Instructions

Please read these instructions carefully before fitting and retain for reference. Check the packaging and make
sure that you have all the required parts. Follow each assembly step in order to prevent incorrect assembly.
Ensure that the product is fully assembled as illustrated before use.
This type of Light Fitting may be connected to a Dimmer if a Tungsten incandescent bulb is used. If a
CFL/LED type bulb is fitted then these cannot (generally) be controlled by a dimmer.
The Light pack contains:
Light fitting.
Terminal connection block(s).
Fixing pack.
Glass plate.
Decorative drops.
These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
1. Decide on the position of the light fitting, or remove existing light fitting. Take a note of the position of the
electrical connections. Ensure there is a solid mounting surface, preferably a wooden joist or joist bridge to
support the weight of the light fitting.
2. Remove the fixing bracket by undoing the 2 side screws (3), retain for re-use.
3. Use the fixing bracket as a template to mark the screw holes, mark the screw holes and secure to the ceiling
with the fixings (1) supplied.
4. Slide the glass plate (4) over the body of the fitting so it rests on the lip, and secure in place with the metal
tab and screw (5)
Endon Lighting, LS9 0SE
Renner 6-Light Flush Fitting
INSTRUCTION MANUAL
Before you start
The following tools may be required:
Selection of cross and flat head screwdrivers.
Electric drill and assorted drill bits.
Wire strippers.
Electrical insulation tape.
57509-Renner6lt-F 20160429

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Renner 6-Light Flush Fitting and is the answer not in the manual?

Questions and answers

Summary of Contents for Endon Renner 6-Light Flush Fitting

  • Page 1 Renner 6-Light Flush Fitting INSTRUCTION MANUAL Safety Warnings • This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE wiring Regulations and should be installed in accordance with local Building Regulations and is for Domestic indoor ceiling use only and not suitable for a Bathroom location. • The light fitting should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp miniature circuit breaker). • This product is a Class I fitting and must be Earthed. • If in doubt we recommend you contact a qualified electrician. Before installing your light fitting always switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker before commencing installation, and ensure that no one else has access that would enable the supply to be inadvertently reconnected. • Never fit bulbs of a higher wattage or of a type other than those specified on the label as this may cause overheating and damage the fitting. • These product contains glass parts – be careful during handling and maintenance to avoid breakage. • If any modification is made it will invalidate the warranty and may render the product unsafe. Care Information Allow 10 minutes to cool before replacing, adjusting or cleaning. Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product. Assembly/ User Instructions Before you start Please read these instructions carefully before fitting and retain for reference. Check the packaging and make sure that you have all the required parts. Follow each assembly step in order to prevent incorrect assembly.
  • Page 2 7. Fit the decorative drop assemblies (6-8) as shown. 8. Fit the bulbs (9) into the lamp holders being careful not to touch the bulbs with your bare hands – use a cloth or gloves to insert the bulbs. NOTE: Never fit bulbs of a higher wattage or of a type other than those specified on the label (as these may cause overheating and damage the fitting). 9. Turn on the power and test. X20pcs X15pcs X10pcs X5pcs X1pcs Endon Lighting, LS9 0SE 57509-Renner6lt-F 20160429...

Table of Contents