V
L
I E W
E V E L S
There are three View Levels to the menu
Operator – A very simple level . No setup allowed
Basic – Default mode of the menu. Allows quick
setup, save, restore and full diagnostics
Advanced
-
Allows
full
access
to
comprehensive set of function blocks in the Setup
menu and more choices in the System menu to
choose Language defaults and more
View Levels may be selected from the Quick
Setup menu, under View Level
M
A C R O S
The 690+ comes packaged with several Macros,
which are preconfigured schemes. Current macros
include
Basic speed control - Load this to return to factory
default parameters
Raise/Lower – Pushbutton ramp using increase/
decrease inputs
PID – Provides closed loop process control
SPW – Speed program winder (closed loop trim)
PRESET SPEEDS – Provides 8 preset speeds
To load a Macro, go to SYSTEM\RESTORE
CONFIG and select the macro you wish to load
I
L
N T E R N A L
I N K S
Under SETUP\LINKS, you may connect and dis-
connect internal block diagram connections, to use
special functions like PID, winder blocks, diameter
block, etc., and to tag analog and digital I/O to se-
lected points inside the drive to suit your applica-
tion needs. Specify sources and destinations to 50
internal links.
T
B
E C H N O L O G Y
OX E S
The 6055 series of Technology
boxes
is available to communi-
cate with protocols such as De-
viceNet,
PROFIbus,
ModBus,
RS485 serial comms, CAN bus
and LON works.
Any of these
may be plugged into the right-side
techbox port. Securely snap into
place, then tighten the ground
screw
Networking a standard 690+ to
LINK
is done
LINK
with the
techbox. This has a built-in proc-
essor that can be configured using DSD, the
Associated Literature
690+ Installation Manual HA465492Uxxx
690+ Software
Manual HA465038Uxxx
6 9 0 +
6 9 0 +
the
Q u i c k S t a r t
Q u i c k S t a r t
Flux Vector
Sensorless Vector
Volts/Her tz
f r a m e s C
-
F
f r a m e s C
-
F
1 5
-
1 5 0 H P
1 5
-
1 5 0 H P
7 . 5
-
9 0 k W
7 . 5
-
9 0 k W
Visit us at www.SSDdrives.com
USA: (704) 588-3246
UK: +44 (0)1903 737000
HA470631U200
*HA470631U200*
B
E F O R E
This document covers the steps necessary
for a basic start up of the 690+ drive. Drive
start ups should be performed by qualified
electrical technicians who are familiar with
AC drives and their applications. For de-
tailed installation and safety information
refer to the Installation Manual. For ad-
vanced features and applications, refer to
the Software Manual.
Ensure that all local electric codes are met
while installing the drive. Check that all live
parts are covered to protect against electric
shock and that unexpected rotation of the
motor will not result in bodily harm or injury.
This document expects that the drive is
already installed in its intended location
and that all relevant installation procedures
have been followed. Please ensure that the
drive has adequate ventilation so that am-
bient temperature does not exceed 45°C
(112°F) under normal operating conditions.
To access the terminals, loosen the two
retaining screws at the bottom of the drive,
pull up gently on the terminal cover and
slide it off.
C
O N T R O L
The 690+ supports 3 different
modes
Volts/Hertz mode – Most basic open loop
operation, used in fans/pumps and multi-
motor applications. No options needed
Sensorless Vector mode – Tight speed
regulation with good transient torque
capability, without the need for speed
feedback. No options needed
Flux Vector mode – Precise flux vector
control with full torque down to zero speed
and
improved
Optional Speed Feedback Technology
Card required on the drive and an encoder
Issue 5
on the motor
Y
S
P
O U
TA R T
O W E R
3 phase power
3 phase power
3 phase power
3 phase power
The power terminals shown are for frame D.
Although other frames may vary slightly in
appearance, their terminal designations and
functionality are identical
•
3-phase supply to L1, L2, L3.
M
•
O D E S
Motor connections to M1, M2, M3
•
Brake resistor between DBR+, DBR-
•
Motor thermistor to MOT TEMP
•
Common Bus to DC+, DC-
control
•
Frame F only: 115/230V fan supply to
L,N
Ground lugs have been provided for each
of the power circuits. Follow proper ground-
ing and shielding methods as described in
chapter 3 of the Installation Manual,
If the stop time is expected to be less than
the natural coasting time of the load, order
the factory mounted braking module option
dynamic
performance.
on frames D through F. Frame C has a
built-in braking module. Connect the brak-
ing resistor across DBR+ and DBR-.
C
O N N E C T I O N S
~
~
~
~
braking
braking
braking
braking
motor
motor
motor
motor
resistor
resistor
resistor
resistor
thermistor
thermistor
thermistor
thermistor
Need help?