Summerset Professional Grills SSSB-1 Owner's Manual

Advertisement

Quick Links

Side Burner Owner's Manual

Safety and Installation Instructions

Side Burner Installation-NOTE-FOR OUTDOOR USE, ONLY!
This gas side burner must be installed in accordance with all local codes.
If installation is planned in an area with no local codes, the gas side burner must be installed in accord with the National Fuel Gas Code ANSI
Z223.1 and storage and handling of liquefied petroleum gases, ANSI/NFPA 58 or CSA B149.1 natural gas and propane installation code.
CALIFORNIA PROPOSITION 65 WARNING
The burning of gas cooking fuel generates some by-products which are on the list of substances which are known by the State of California to
cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure to such substances. To minimize
exposure to these substances, always operate the unit according to the use and care manual, ensuring you provide good ventilation when cooking
with gas.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, and void the warranty. Read
the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

Clearances

Combustible Construction

Minimum horizontal clearance from sides and back of the unit to adjacent vertical combustible construction extending above top of unit, 24 inches
from side and 24 inches from back. Do not locate under any overhead combustible construction.

Non-Combustible Construction

Sides of the side burner can be 0" from non-combustible wall, below the cooking surface.

Built-in Installation

For non-combustible cabinet enclosure installation only. Follow the cut-out dimensions as shown. ALL outdoor kitchen cabinets MUST include
ventilation. We recommend 12 square inches of opening for each (running) 4 feet of counter top. See Item # RVNT1 for approved vents.

Natural Gas Connection:

Appliance pressure
4" W.C.
Inlet pressure
5" – 14" W.C.
Summerset side burners have 3/8" male flare connection
www.summersetgrills.com

Cut Out Dimensions

A - Width
Model #
SSSB-1
8 1/2"
SIZSB-2
10 3/4"
TRLSB-2
11 3/4"
SSEAR-1
11 3/4"

Propane Gas Connection:

Appliance pressure
10" W.C.
Inlet pressure
11" – 14" W.C.
B - Depth
C - Height
16"
N/A
20 3/4"
8 1/2"
19"
9"
19"
9"

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSSB-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Summerset Professional Grills SSSB-1

  • Page 1 We recommend 12 square inches of opening for each (running) 4 feet of counter top. See Item # RVNT1 for approved vents. Cut Out Dimensions A - Width B - Depth C - Height Model # SSSB-1 8 1/2" 16” SIZSB-2 10 3/4” 20 3/4"...
  • Page 2: Lighting Instructions

    4. If there is no ignition after trying, turn the knob back to the “OFF” position and repeat steps 2-3. *DO NOT LEAVE YOUR SIDE BURNER UNATTENDED WHILE IN OPERATION.* Fuel Conversion for Side Burners: SSSB1, SIZSB-2, TRLSB-2, SSSEAR-1 Find the extra set of orifices that came with the side burner. SSSB-1 SIZSB-2 TRLSB-2 SSEAR-1...

This manual is also suitable for:

Sizsb-2Trlsb-2Ssear-1

Table of Contents