T-Link TL300 Quick Installation Guide
TL300
The T-Link TL300 connects directly to the telephone output of a control panel and simulates a
telephone connection, providing a UDP Internet connection. The T-Link TL300 on-board zones
can be used as in mode 2 (4-zone stand-alone) and mode 3 (12-zone stand-alone). Modes 1, 4
and 5 are not supported.
STEP 1 - Resetting to Factory Defaults
Hardware Defaults
Remove Power from the T-Link TL300; disconnect battery and control panel if applicable
Connect a jumper wire between the PGM1 and IN1 terminals
Apply power to the system
Wait approximately 20 seconds then remove the short between PGM1 and IN1.
The T-Link TLTL300 can be Defaulted through the panel keypad
Enter Section [999] of the T-Link TL300
Enter data [00] to default the unit to factory settings
Enter data [55] to restart the unit.
STEP 2 - TL300 Panel Installation
Secure the T-Link TL300 module to the side of the cabinet of the control panel or install
the T-Link TL300 in a DSC enclosure (model PC5003C). Refer to Appendix B: T-Link
TL300 Compatibility Chart for a list of panels supported
Wire the panel's 12VDC and GND terminals of T-Link TL300or Power unit with a 12VDC,
225 mA UL Listed Power supply.
Wire the panel's TIP and RING terminals to the T1 and R1 terminals of T-Link TL300.
Apply AC and DC to the main control panel. Both the T-Link TL300 and the panel will
power up.
Quick Install Guide

Advertisement

loading

Summary of Contents for T-Link TL300

  • Page 1 Enter data [55] to restart the unit. STEP 2 - TL300 Panel Installation Secure the T-Link TL300 module to the side of the cabinet of the control panel or install the T-Link TL300 in a DSC enclosure (model PC5003C). Refer to Appendix B: T-Link...
  • Page 2 Local programming of basic options can be done through a standard DSC Power LCD keypad. Connect the keypad on the T-Link TL300 Keybus terminals. Access to programming mode uses the same code as the console (default is '5555'). All other sections will have to be programmed via the TLINK console software •...