Coverage Pattern And Plan View
HORIZONTAL COVERAGE
15m
12m
10m
8m
6m
4m
2m
Dual Tech
PIR
Operation of Features
Initial Power Up
®
On first power up of the TMD15G3, the detector will go into a self test, this will
involve the GREEN and ORANGE LEDs flashing on the dual tech, and the RED
LED flashing on the PIR. After a minute the detector will be ready.
If the ORANGE LED is still flashing then the detector has failed a Microwave test,
or if the GREEN LED or RED LED is still flashing then the detector has failed a PIR
test, if this occurs try restarting the detector (powering down and back up).
Self Test
Every 5 hours of detector none activity the detector will do an active diagnostic self
test. If in the unlikely event of a failed self test the detector anti-mask/fault relay will open.
Low Voltage Detect
If the detector detects a low voltage fault, then the anti-mask/fault relay will open
The EN anti-mask Operation
FOR EN OPERATIONS DIP SWITCH 6 MUST BE ON
®
If an attempt is made to anti-mask the TMD15G3 the BLUE LED will start flashing at
half a second intervals, signaling that the detector is going into 'anti-mask processing'.
anti-mask processing will take 60 seconds to complete.
If the detector still sees a anti-mask after 60 seconds then the anti-mask/fault and
Alarm relays open, and the GREEN and ORANGE LEDs will be illuminated.
For None EN operation just the anti-mask/fault relay goes open.To select which relays to
open on a anti-mask activation see dip switch 6.To reset the detector to normal operating
mode, remove the blocking material, the BLUE LED will then flash again and during
this time the detector should be walk tested to activate both Microwave and PIR, the
GREEN and ORANGE LED will distinguish after 60 seconds and the relays will be
closed again.If the detector has been put into anti-mask processing by accident, you will
need to walk test the detector so both the Microwave and PIR trigger, after 60
seconds the BLUE LED will stop flashing and normal operation is resumed.
Switch 1. 50/60Hz
ON
= 50Hz
OFF
= 60Hz
Switch 2. Anti-anti-mask Mode
This controls when the anti-masking algorithm is applied. When the DIP switch is
(Default), the anti-masking algorithm is enabled regardless of the set/unset status of
the detector. When the DIP switch is
OFF,
the anti-masking algorithm is enabled when
the RI1 is in the unset state.
Switch 3. Blocking
ON = Blocking Disabled / OFF = Blocking Enabled
'Blocking' works as follows: If an attempt to anti-mask the detector is made when the
control panel is disarmed, the alarm relay will be held open until the anti-masking is
removed (thus not allowing the control panel to arm). You must also connect the
®
"RI 1" input on the TMD15G3 to a programmable output. When the control panel
is disarmed, this input must be at 0V. When the panel is armed it must be at 12V.
To enable this feature dip switch 3 must be OFF.
VERTICAL COVERAGE
Maximum Range Setting
2.4m
6ft 6"
2m
4m
6m
8m
10m
Minimum Range Setting
2.4m
6ft 6"
2m
4m
6m
8m
10m
Dual Tech Lens
Volumetric
90
30 Zones
3 Planes
PIR Lens
3mm
Volumetric
15m
50ft
(0.12")
69
24 Zones
3 Planes
Switch 4. RI 1 Mode
A link on board marked "RI1/Spare" determines if the RI1 terminal is used for the
set/unset signalling or simply as a spare terminal to aid EOL wiring.
If the RI1/Spare link is fitted, the state of RI1 determines if the panel is set or unset.
The actions that can be performed in set and unset mode are also determined by
DIP switch 4 and 2. DIP switch 4 controls the action of RI1. If the switch is
detector will operate permanently in Set Mode. When DIP switch 4 is
detector will use the state of RI1 to determine the set or unset state.
A 0V applied to input RI1 is interpreted as being unset.
A +12V applied to input RI1 is interpreted as being set.
DIP switch 2 determines if anti-masking is enabled all of the time or only when the panel
is unset. When nothing is connected to RI1, the input state is in the set state.
Switch 5. Dual Tech (Alarm 1) Sensitivity
ON = Auto Sensitivity / OFF = High Sensitivity
The bottom PIR will always remain in Auto Sensitivity
Switch 6. Anti-anti-mask Relay Action
FOR EN OPERATION DIP SWITCH 3 MUST BE OFF
ON = Open Both anti-mask and Alarm Relays
Example of a control panel input looking for a anti-mask value of 13k7. See below
Alarm relay = 4k7, Tamper EOL = 2k2, anti-mask/Fault relay = 6k8.
None EN operation only anti-mask relay opens.
OFF = Opens anti-mask Relay Only
Example of a control panel input looking for a anti-mask value of 14k2. See below
Alarm relay = Closed, Tamper EOL = 2k2, anti-mask/Fault relay = 12K.
Switch 7. Operational mode
.
ON = TMD Mode
DIP Switch 7 determines the operational mode of the detector. When the switch is
®
ON (default) will operate as a TMD15G3 , where the Dual Tech and the Single PIR
operate independently.
To open alarm contact 1, the Dual Tech's PIR must trigger within a given time period
of the microwave sensor. Alarm contact 2 is based on the operation of the Single PIR
ON
only.
.
®
OFF = TriCover
Detector Mode
When switch 7 is OFF, the detector will operate as a TriCover detector, with
all technologies needing to trigger within a given time period of each other to open
alarm contact 1. Alarm contact 2 will operate in the inverse of alarm contact 1.
In alarm, the only LED to be illuminated will be the Dual Tech alarm LED.
Switch 8. LED Enable/Disable
ON = LED Enable / OFF = LED Disable
To remotely enable the LEDs 0V must be applied to the "LED" terminal.
If used with Pyronix panels, the LED terminal must be connected to a PGM
output and programmed as "Remote LED Enable".
For Standard G3 operations the DIP switches do not need to be adjusted.
TS50131-2-4
EN50131-1
PD6662:2004
Security Grade 3
Environmental Class 2
®
TMD15 Specifications
Model:
TMD 15
12m
15m
Colour:
WHITE
Casing:
3mm ABS, 0.4mm HDPE in Lens Area
Lenses:
2 Volumetric Lenses, with NO
overlapping zones
Detection Method:
2 Low noise dual element passive infrared
sensors and a microwave doppler unit
12m
15m
Dual Tech Sensitivity:
Selectable AUTO or HIGH
Temperature Compensation:
Digital
Microwave Detection Range:
15m PIR and 1-15m microwave
anti-mask Detection Range:
0m - 1m anti-masking
Detection Zones:
27 facets,54 zones in total.
Top Lens
90 field of view none-overlapping zones
Bottom Lens
69 field of view none-overlapping zones
Detection Speed:
0.25 - 2.5m/s
Operating Voltage:
9-16Vdc, 13.8Vdc typically
Current Consumption:
24mA @ 13.8Vdc Quiescent
Relay Output:
3 x SELV limits; 60Vdc 50mA (42.4Vac peak)
Mounting Height:
1.8 - 2.4m = 15m.
Tamper Switch:
12Vdc 50mA both front and rear
Storage Temperature:
-40 C to +80 C (-40 F to +176 F)
Operating Temperature:
-30 C to +70 C (-22 F to +158 F)
Emissions:
EN55022 Class 2
Immunity:
EN50130-4
ON
the
OFF,
the
Suggested Specification Detail:
A dual technology (PIR/Microwave) movement detector having a range capability
of 15 metres and five detection columns within an overall angle of coverage of 90
degrees. This is non-overlapping with a PIR movement detector, which has a
range capability of 15 metres and four detection columns with an overall angle of
coverage of 69 degrees installed in the (location) and at a height of (x) metres.
Switch Options
SWITCH
FEATURE
POSITION MEANING
1
50/60Hz
ON
OFF
2
Anti anti-mask
ON
OFF
3
Blocking
ON
OFF
4
RI1 Mode
ON
OFF
5
Sensitivity
ON
OFF
6
anti-mask
ON
®
OFF
7
Operational
ON
Mode
OFF
8
LED Enable
ON
OFF
INTERNATIONAL
®
15m Internal detector
: 5 columns, 15 facets, 30 zones
: 4 columns, 12 facets, 24 zones
3m = 12m
INTERNATIONAL
This product is approved for use in the Residential,
Commercial and Light Industrial Environment.
This product complies with TS50131-2-4. at security grade 3,
50Hz
UK = Suitable for use with systems installed to PD6662:2004 (AMD)
EXPORT = Suitable for use with systems installed to EN50131-1
60Hz
24 Hour
Customer Support Line (UK only):
Anti-anti-mask only enabled in
+44(0)845 6434 999 or or +44(0)1709 535225
unset mode
Blocking processing Off
Hours: Mon to Fri, 8:00am till 6:30pm
Blocking processing On
Email: customer.support@pyronix.com
Permanent in Set Mode
State of Ri1 = set/unset mode
Pyronix Limited, Pyronix House, Braithwell Way,
Dual Tech = AUTO
Hellaby, Rotherham, S66 8QY. UK
Dual Tech = HIGH
Open anti-mask & Alarm relays
This product is sold subject to our standard warranty
when in anti-mask
conditions and is warranted against defects in
Open anti-mask relay only when
workmanship for a period of five years.
in anti-mask
In the interest of continuing improvement of quality,
Two movement detector
customer care and design, Pyronix Ltd reserves the
®
TriCover detector
right to amend specifications, without giving prior
Enable LEDs
Disable LEDS
®
TS50131-2-4
EN50131-1
PD6662:2004
Security Grade 3
Environmental Class 2
environmental class 2.
Website: www.pyronix.com
WARRANTY
notice.
RINS1405-1

Advertisement

loading

Summary of Contents for Pyronix TMD15

  • Page 1 ® “RI 1” input on the TMD15G3 to a programmable output. When the control panel If used with Pyronix panels, the LED terminal must be connected to a PGM notice. LED Enable Enable LEDs is disarmed, this input must be at 0V.
  • Page 2 60Hz Red (Alarm) ensure that it is mounted vertically Bottom = 5m ® The Wiring Connections For The TMD15 (Examples) Grade 3 Configuration (DEOL) Grade 2 Configuration Grade 2 Configuration TriCover® mode configured to a single input with anti-mask TriCover® Mode SEOL Wired to a single input with anti-mask...