Download Print this page

GUILIN SENJIE Technology SJ300 Manual

Digital gaussmeter

Advertisement

Quick Links

Digetal
Guassmeter
SJ300
Manual
Please keep manual properly.
Before using our equipment
please read the instruction
manual seriously.
TEL:+86-18577332938 FAX:+86-571-85223021
GUILIN SENJIE Technology Co.,Ltd.
http://www.pf-bst.com/
E-mail:25087817@qq.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the SJ300 and is the answer not in the manual?

Questions and answers

Summary of Contents for GUILIN SENJIE Technology SJ300

  • Page 1 Digetal Guassmeter SJ300 Manual Please keep manual properly. Before using our equipment please read the instruction manual seriously. TEL:+86-18577332938 FAX:+86-571-85223021 GUILIN SENJIE Technology Co.,Ltd. http://www.pf-bst.com/ E-mail:25087817@qq.com...
  • Page 2 avoid condensation. Introduction Introduction Introduction Introduction 15 Never place the instrument in close the machine generating strong magnetic field, The Telemeters is a special instrument used for inspecting & checking flux such as magnet-charger, demagnetize coil, microwave oven, electric welding density ,which is also one of the most universally devices in the field of magnetic equipment electric motor and etc.
  • Page 3 Working Working Working Working Principle Principle Principle Principle The instrument is guaranteed to keep in good repair for 12 months except the This series of instruments use sensors which are made according to Hall Effect. probe. The circuit adopts precision constant current source, amplifier with low drift and high Do not use the instrument in inappropriate conditions.
  • Page 4 I—Current intensity passing through the Hall device new peak value and the forecast value will be lower forecast. Thus you could press B0—The measured magnetic induction intensity the Reset button (4) to make it showing new peak value. It can be seen from the formula: For a certain Hall device, the magnetic field B0 can be indirectly measured through measuring the Hall device if only the 10.
  • Page 5 surface. Under such circumstances, the probe surface will suffer wear and Measurement of Peak-value holding.Press the key (4) to change over normal tear. measurement or Peak-value holding. The connecting cable of the probe shall not be kneaded or pulled forcibly, the probe bracket shall not be beaten or impacted and the probe lead wire and welding spot shall not be contacted with other conductor or in short circuit.
  • Page 6 Main Main Main Main Technical Technical Technical TechnicalParameters Parameters Parameters Parameters 5. Select display unit.Press the key (7) of conversion, the display unit would be Range 0~200mT~2000mT transformed from mT to Gs. Accuracy ±2%,±3 words; ±5%,±5 words(1000mT) Sensitivity 0.01mT,0.1mT Measured magnetic field 6.
  • Page 7 5℃~40℃ Temperature environment 20%~80%(no condensation) Relative humidity Battery 9V,Or 9V DC external power supply Power Supply Horizontalsensor Verticalsensor regulator 150mm(L)*70mm(W)*25mm(H) Dimension 3. Press the key of the Power On/OFF in the panel and the digital display screen N.W 400g G.W 900g Weight should display zero.
  • Page 8 Manipulation Manipulation Manipulation Manipulation Procedure Procedure Procedure Procedure 1. Put the 9V battery to case which in the back of the instrument; if used the outer power, connect the terminal of the power to the socket which is in the side of the instrument and put another plug to electric supply.