Status Screen - Weil-McLain Evergreen 70 User's Information Manual

Condensing gas boiler
Table of Contents

Advertisement

®
gas
The Evergreen
Figure 6
Evergreen
boiler control display states
®
L O A D I N G
B O I L E R
M O D E L
E V E R G R E E N
# # #
B O I L E R
I D :
S I N G L E
B O I L E R S
O N
N E T W O R K : 1
S Y S T E M
S E N S O R S : A T T A C H E D
O U T D O O R
S E N S O R : A T T A C H E D

STATUS SCREEN

H H : M M A M
M M / D D / Y Y
S T A T U S :
O U T D O O R
T E M P :
T A R G E T
T E M P :
B O I L E R
T E M P :
M O D U L A T I O N :
I N P U T
S T
A T U S :
0- 1 0 V:
1:
D H W - S T A N D B Y
2:
R A D F L O O R - R U N N I N G
3:
P U M P S / A U
X :
1
2
A D D 'L
H E A
M A
T
D E
M A N U A L
R E S E T
P R E V I O U S
S E T T I N G S
10
-
fired water boiler
control display
®
Loading
bar
Boiler ID number
Shows if system sensor is connected
Shows if outdoor sensor is connected
N E X T
Select to show Status screen, below
Move selection up
Move selection down
Next screen
Previous screen
Enter
Time and date (also flashes fault name during lockout)
Active system type
°
Outdoor air temperature
# # #
F
Setpoint temperature or percentage (if shadow)
°
# # #
F
Boiler out or system sensor (depending upon settings)
°
# # #
F
Firing Rate
"Input Voltage" + "Setpoint" or "Modulation"
}
Status of inputs 1, 2 and 3
Pumps being energized
3
B L R
Add'l heat demand contact status
N D :
# # #
Shown only during a lockout/fault
Press the right arrow button to go to the Settings screen
70/110/155 User's information Manual
Operating Screen, typical
H H : M M A M
M M / D D / Y Y
# # #
B O I L E R
I D :
E V G
M O D U L A T I O N :
B L R
T E MP: # # # °
F
S Y S
T E MP: # # # °
F
S T A T U S :
P R E P U R G E - # # #
D E M A N D :
1
2
3
N E X T
Screen colors
(Blue = space heating or when any button is pressed)
(Screen will show solid red, with the exclamation mark
symbol, if a non-shutdown failure occurs; i.e., failure of a
non-critical sensor, such as outdoor or system supply or
return sensor.)
Display above is typical for normal
operation. The center symbol changes to
show operation status.
Press to switch to
INFO screen.
The INFO screen, below is for at-a-glance
information during normal operation.
(Pressing any button changes
background to blue, below.)
H H : M M A M
Boiler type and
B O I L E R
ID number
Mod rate or Fault
Boiler and system
S T A T U S : S T A N D B Y
temperatures
D E M A N D :
Current heat
demands
SPACE HEATING
H H : M M A M
B O I L E R
S T A T U S :
D E M A N D :
DHW HEATING
(Domestic hot water heating)
H H : M M A M
B O I L E R
S T A T U S :
D E M A N D :
BOILER IN LOCKOUT
(Attention required to
H H : M M A M
B O I L E R
S T A T U S :
D E M A N D :
Alternating colors
H H : M M A M
B O I L E R
S T A T U S :
D E M A N D :
Solid red screen with
symbol means a
warning; with ! symbol
means auto reset action.
EVG-001
Part number 550-100-192/0917
STANDBY
M M / D D / Y Y
I D :
E V G # # #
M O D U L A T I O N :
B
L
R
T E M P: # # # ° F
S Y S
T E M P: # # # ° F
N E X T
M M / D D / Y Y
I D :
E V G # # #
M O D U L A T I O N :
B L R
T E MP: # # # °
F
S Y S
T E MP: # # # °
F
P R E P U R G E - # # #
1
2
3
N E X T
M M / D D / Y Y
I D :
E V G # # #
M O D U L A T I O N :
B L R
T E MP: # # # °
F
S Y S
T E MP: # # # °
F
P R E P U R G E - # # #
1
2
3
N E X T
restart boiler)
M M / D D / Y Y
I D :
E V G # # #
L O C K O U T
# # # # # # # # # # # #
# # # # # # # # # # # #
B L R
T E MP: # # # °
F
S Y S
T E MP: # # # °
F
L O C K O U T
1
2
3
N E X T
M M / D D / Y Y
I D :
E V G # # #
L O C K O U T
# # # # # # # # # # # #
# # # # # # # # # # # #
B L R
T E MP: # # # °
F
S Y S
T E MP: # # # °
F
L O C K O U T
1
2
3
N E X T
. . .