LD Medical LD-576 Instruction Manual

Talking automatic

Advertisement

TALKING AUTOMATIC
DIGITAL BLOOD PRESSURE MONITOR
INSTRUCTION MANUAL
Article No. : 06456 (Factory Ref. No. LD-576)

Advertisement

Table of Contents
loading

Summary of Contents for LD Medical LD-576

  • Page 1 TALKING AUTOMATIC DIGITAL BLOOD PRESSURE MONITOR INSTRUCTION MANUAL Article No. : 06456 (Factory Ref. No. LD-576)
  • Page 2 PARTS AND COMPONENTS 1. Main Body 2. Display 3. Air Connector 4. Tube Plug 5. Air Hose 6. Cuff 7. D-ring 8. Button ‘M1’ 9. Button ‘M2’ 10. Button ‘ ’ 11. Batteries (Not Included) 12. Adapter (Not Included) 13. Adapter Jack...
  • Page 3 SYMBOLS Symbols Meaning Manufacturer Authorized Representative in the European community Symbol for the marking of electrical and electronics devices according to Directive 2002/96/EC. The device, accessories and the packaging have to be disposed of waste correctly at the end of the usage.
  • Page 4: Table Of Contents

    TABLE OF CONTENT 1. GENERAL -PRINCIPLE OF OPERATION -NEW TECHNOLOGIES USED 2. TIPS ON TAKING BLOOD PRESSURE MEASUREMENT 3. BATTERY INSTALLATION 4. USEING THE DEVICE WITH AC POWER ADAPTER 5. CORRECT POSTURE FOR MEASUREMENT 6. ASSEMBLING THE CUFF 7. CARRYING OUT A MEASUREMENT -RAPID DEFLATION DURING MEASUREMENT 8.
  • Page 5: General

    This instruction manual is intended to assist the user for safe and efficient operation of the automatic digital talking blood pressure monitor (hereinafter: device) model LD-576. The device must be used in accordance with the procedures described in the manual. It is important to read and understand the entire manual, especially the section <Tips on taking blood pressure...
  • Page 6: Tips On Taking Blood Pressure Measurement

    TIPS ON TAKING BLOOD PRESSURE MEASUREMENT 1.It is necessary to know that arterial blood pressure is subjected to sharp fluctuations. The level of the arterial blood pressure depends on many factors. Generally arterial blood pressure is lower in summer and higher in winter.
  • Page 7 4.It is necessary to keep quiet during measurement accurate readings. Measurement should be conducted in quiet environment at room temperature. Don’t eat or smoke before a measurement. This device is supplied with the standard cuff which is fit for the arm size 22-32 cm.
  • Page 8: Battery Installation

    BATTERY INSTALLATION 1.Open the battery cover and install four ‘AA’ type batteries into the battery compartment as indicated. Make sure that the polarity is correct; 2.Close the battery compartment cover. Replace the batteries when the replacement indication “ ”appears in the display or nothing after “ ”...
  • Page 9: Correct Posture For Measurement

    Note: The monitor is designed not to draw power from the batteries when the AC adapter in use. Optional AC adapter technical feature: Output voltage: 6V±5% Max. output current: At least 600 mA Output plug polarity: <-> inner CORRECT POSTURE FOR MEASUREMENT CORRECT POSTURE FOR MEASUREMENT 1.Sit beside the table and let the table support your arm as you take the measurement.
  • Page 10: Assembling The Cuff

    ASSEMBLY THE CUFF 1.Insert the edge of the cuff approximately 5 centime- ters into the D-ring as shown in figure. 2.Put the cuff on the left upper arm with the tube pointing to the direction of palm. If measurement on your left arm is difficult, you can use right arm for measurement.
  • Page 11: Carrying Out A Measurement

    CARRYING OUT A MEASUREMENT 1. Insert the air hose into the air connector. Before the measurement, take 3~5 times deep breath and relax yourself. Don’t talk or move your arm; 2. Press button ‘ ’, and all symbols will appear on display in Fig.1 2 seconds as in Fig.1.Two short beep will sound and the LCD backlight will light in orange.
  • Page 12: Setting The Date And Time

    SETTING THE DATE AND TIME The function provides accurate measuring time for each measurement. To get an accurate date and time, the user should preset the date and time correctly before the first use of this device. The operation procedure for presetting Date/Time is as follows: 1.
  • Page 13: Setting The Languages

    SETTING THE LANGUAGES There are three languages of voice for choice, it includes English, French and German. To adjust the languages: 1. Press button ‘M1’ and don’t release, then press button ‘ ’ three times until the language icon displays on the LCD as in Fig.8 Fig.8 2.The device will show“L1”(English is the default when the device is used in first...
  • Page 14: Function Of Memory

    FUNCTION OF MEMORY 1.The device can store 90 sets of readings respectively in ‘M1’ and ‘M2’, and will automatically calculate the average value of the latest 3 readings for ‘M1’ and ’M2’. When the memory is full (90 sets of readings are stored), the oldest reading will be replaced by a new one.
  • Page 15: Who Blood Pressure Classification Indication

    IRREGULAR HEARTBEAT DETECTOR Model LD-576 digital blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. When the device detects the irregular heartbeat or any excessive body movement during measurement, the ‘...
  • Page 16: Error And Low Battery Information

    ERROR AND LOW BATTERY INFORMATION INDICATION POSSIBLE REASON CORRECTION METHODS The cuff is put on Make sure that cuff is put on correctly wrongly or the tube plug and the tube plug is inserted tightly is inserted too loosely. and repeat the measurement. Movement of arm/hand Repeat the measurement with or talking during...
  • Page 17: Troubleshooting

    TROUBLESHOOTING SYMPTOM CHECK POINT REMEDY No display when The batteries have run down. Replace all the batteries with connect the power. The polarity of battery is wrong. new ones. The contact of battery Install the batteries correctly. compartment is polluted. Clean the battery terminals with dry cloth.
  • Page 18: Specifications

    Access to information channels and procedures, please contact your dealer or manufacturer. SPECIFICATIONS 06456 (LD-576) Model Size 105(L) ×120(W) ×55(H)mm Weight...
  • Page 19: Blood Pressure Record

    HONSUN (NANTONG) Co., Ltd. Address:No.8 Tongxing Road Economic & Technological Development Area 226009 Nantong City PEOPLE’S REPUBLIC OF CHINA SHANGHAI INTERNATIONAL HOLDING CORP. GMBH (EUROPE) GERMANY Address: Eiffestrasse 80, 20537 Hamburg Distributor: MDL Medical, 2 Route de Californie, 07100 Annonay, France BLOOD PRESSURE RECORD PULSE SYSTOLIC...
  • Page 20: Manufacturer's Declaration

    MANUFACTURER’S DECLARATION Guidance and manufacturer’s declaration – electromagnetic immunity The model LD-576 Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the model LD-576 Digital Blood Pressure Monitor should assure that is used in such an environment.
  • Page 21 IEC 61000-4-8 Portable and mobile RF communica- tions equipment should be used no closer to any part of the LD-576 Digital Blood Pressure Monitor Equipment, including cables, than the recommend- ed separation distance calculated from Conducted RF...
  • Page 22 RF communications equipment and the LD-576 Digital Blood Pressure Monitor The LD-576 Digital Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of...
  • Page 23: Quality Guarantee

    QUALITY GUARANTEE MODEL Warranty period Two years from purchasing date Purchasing date Name: Telephone: Purchasing shop Address: Name: Telephone: Customer Address: REQUIRING RECORD Date TROUBLE SERVICE MAN 1.During warranty period the repair could be made at any BPM repair department. 2.
  • Page 24: Periodic Safetry Checks

    PERIODIC SAFETRY CHECKS If you use the device with power adapter, preventive inspection and mainte- nance to be performed including the frequency of sunch maintenance. Every time before use, please check the adapter, once damaged, never to use. Please clean the plug of adapter plug at least once a year. Too much dust on plug may cause the fire.

Table of Contents