Download Print this page

Genlilin B110/05 Instruction Manual

B110 series

Advertisement

Quick Links

COMPRESSOR B110
INSTRUCTION
MANUAL
MOD.
FIG. 1
1
2
3
4
5
6
RH side view
2- TECHNICAL SPECIFICATIONS
Supply voltage/Frequency
Nominal power
Max. operating pressure
Driveshaft rotation speed
Tank volume
Performance (aspirations/yield)
Temperature/air humidity
Total weight
Dimensions (lxwxh)
3- CE DECLARATION OF CONFORMITY
The Manufacturer declares that the compressors B110/05
The CE marking certifies the compliance of the machine with the essential health and safety requirements established by the product Directives
applied. It takes the form of a polyester sticker, with a black thermal transfer mould, which are applied on the motor frame
5- IMPORTANCE OF THE MANUAL
BEFORE USING THE APPLIANCE IN QUESTION, AUTHORISED USERS MUST READ AND UNDERSTAND THE PRESENT INSTRUCTION MANUAL IN ITS ENTIRETY.
The "Instruction Manual" was compiled according to the instructions as specified in
easy and correct understanding of subjects relevant to operators authorised to use and oversee maintenance of the appliance in question.
Should operators find errors, please do not send incorrect personal interpretations/amendments that may threaten safety, rather, we advise
you immediately request the Manufacturer send the correct explanations or further details. The "Instruction Manual" must be accessible by
authorised operators at all times and must be always be kept in a safe place within close proximity of the appliance.
THE PRESENT INSTRUCTION MANUAL FORMS AN INTEGRAL PART OF THE APPLIANCE AND MUST BE KEPT FOR FUTURE REFERENCE AND UP UNTIL THE END
OF APPLIANCE LIFE. IT MUST ALWAYS BE ACCESSIBLE TO AUTHORISED OPERATORS AND IT MUST BE SAFELY STORED AND KEPT WITHIN CLOSE PROXIMITY
OF THE APPLIANCE ITSELF.
THE MANUFACTURER DECLINES ANY RESPONSIBILITY FOR DAMAGE TO PERSONS, ANIMALS AND OBJECTS CAUSED BY INOBSERVATION OF REGULATIONS
AND WARNINGS DESCRIBED IN THE PRESENT INSTRUCTION MANUAL.
IN THE INSTANCE WHERE THE INSTRUCTION MANUAL IS LOST OR DAMAGED, RERQUEST A COPY FROM THE MANUFACTURER OR THE AUTHORISED
SUPPLIER, SPECIFYING THE APPLIANCE MODEL AND THE EDITION NUMBER PROVIDED WITHIN THE TITLE.
THE PRESENT INSTRUCTION MANUAL COMPLIES WITH TECHNICAL PROVISIONS AT THE TIME OF PURCHASE OF THE APPLIANCE AND CANNOT BE
CONSIDERED INCORRECT IN THE INSTANCE WHERE NEW EXPERIMENTATION RESULTS IN UPDATES OF SUCH TECHNICAL PROVISIONS.
THE PRESENT INSTRUCTION MANUAL MUST BE PASSED OVER IN THE INSTANCE WHERE THE APPLINACE IS HANDED OVER TO ANOTHER USER.
This "Instruction Manual" is aimed exclusively at operators authorised to carry out operations according to specific technical skills
necessitated for the operation type. The below described symbols appear at the beginning of paragraphs in order to indicate the identity of
operators affected by the subject described.
AUTHORISED OPERATORS MUST ONLY CARRY OUT OPERATIONS FOR WHICH THEY ARE QUALIFIED.
BEFORE CARRYING OUT ANY OPERATIONS, AUTHORISED OPERATORS MUST POSSESS ADEQUATE PSHYCHO-PHYSICAL CAPABILITES IN ORDER TO ALWAYS
ENSURE SAFETY.
an operator over the age of 18 (private user or employee) and, who, in compliance with current legislation on health
ASSIGNED OPERATOR:
and safety in the work place in force within the country of usage, is capable of exclusively activating, using and deactivating the appliance
whilst completely complying with the instructions presently provided, whilst using the dedicated personal safety device items.
MECCHANICAL/PNEUMATIC MAINTENANCE PERSON:
mechanical/pneumatic parts in order to oversee the regulation, maintenance and/or repairs even with protective devices disabled in
complete compliance with the instructions presently provided or with any other specific document supplied by the Manufacturer, whilst
using the dedicated personal safety device items.
ELECTRICAL MAINTENANCE:
a qualified technician, capable of carrying out exclusive interventions on electrical devices in order to oversee
the regulation, maintenance and/or repairs even where an electric supply is present and even with protective devices disabled in
complete compliance with the instructions presently provided or with any other specific document supplied by the Manufacturer, whilst
using the dedicated personal safety device items.
A person who, depending on his professional skills and within the limits of the hierarchic and functional powers
PERSON IN CHARGE:
appropriate to the nature of the task he has been appointed to perform, supervises work activities and assures the Directives he
receives are implemented, checking the correct performance of the workers and exercising a functional power of initiative.
a qualified technician offered by the Manufacturer and/or Supplier authorised to provide required technical
MANUFACTURER'S TECHNICIAN:
assistance, standard and extraordinary maintenance interventions and/or operations which are not presently included which
necessitate specialist knowledge of the appliance, whilst using the dedicated personal safety device items.
7- STATUS "APPLIANCE OFF"
Before carrying out any type of maintenance and/or regulation operation on the appliance, you must:
1)
Shut off the power supply ensuring that the "
2)
Unplug the power cable
(FIG. 1 - Ref. 7)
3)
Empty the tank
(FIG. 1 - Ref. 14)
(no pressure).
the Manufacturer guarantees the Acquirer, the replacement, repair and intervention relative to all appliances, where
1) WARRANTY DECLARATION:
the aforementioned display conformity defects which comprise correct usage and operation, only where such defects are owing to the fault of
the Manufacturer. The Manufacturer reserves the right to adopt the best solution in order to restore appliance conformity within a
reasonable amount of time.
the Acquirer is defined as a "consumer" where the purchase was made by a physical person and where the appliance is not to be
2) ACQUIRER:
used for commercial or professional purposes;
The Acquirer is defined as a "professional or company" where the purchase was made by a professional or company who aims to use the
appliance for commercial or professional purposes.
the Manufacturer is responsible where the defect of conformity is discovered within the following time frame from the purchase date:
3) TERMS:
24 months where the purchase was made by a "consumer" as described under point 2);
12 months where the purchase was made by a "professional or company" as described under point 2) .
FIG. 2
TIPO / MODELLO
B110/05
TYPE / MODEL
ANNO / YEAR
........
N° DI SERIE /
SERIAL No
.
20 min ON / 10 min OFF - 66% ON
S3
PRESSIONE MAX. ESERCIZIO
9 bar
MAX. WORKING PRESSURE
TENSIONE
..... V / ..... Hz / ..... A
TENSION
VEL. ROTAZIONE ALBERO
...... rpm
SHAFT ROTATION SPEED
POTENZA NOM.
...... kW
RATED POWER
PESO
kg 12.5
WEIGHT
EN
Code
B110/05
CM11163
11
10
9
8
7
V / Hz
110 - 230 / 50
kW
bar
dB
rpm
litri
l / min
110 / 60
°C / %
kg
mm
Conform to the conditions as specified in the following Directives:
2006/42/CE, 2004/108/CE, 2006/95/CE,
97/23/CE (Art.3.3).
And additionally that the following norms have been incorporated
EN 60204-1:2006, EN ISO 12100-1-2:2003, EN 1012-1:1996,
EN ISO
13857:2008, EN ISO 3744:2009.
Person authorised to compose
the technical documentation:
GENTILIN SRL
Via delle Tezze, 20/22 - 36070 Trissino (VI) ITAL Y
01/01/2010
Gentilin Giampaolo
(Administrator)
4- CE LABEL
Machinery Directive 2006/42/CE
6- RECIPIENTS
a qualified technician, capable of carrying out exclusive interventions on
ON (I) -OFF (0)
" switch is in the "OFF (O)" position
(FIG. 1 - Ref. 3)
from the plug located near the appliance;
8- WARRANTY
GENTILIN SRL
Via delle Tezze, 20/22
36070 Trissino (VI) ITAL Y
Tel. +39 0445 962000
Fax +39 0445 491412
Front side
TRANSLATION OF THE
ORIGINAL INSTRUCTIONS
Issue
Revision
30.06.11
00
1- PARTS LIST
12
13
LH side view
the warranty is valid if the buyer notifies the manufacturer of any lack of conformity within 2 months from the date on which the lack
4) VALIDITY:
110 - 230 / 60
was detected. The above mentioned notification must necessarily be accompanied by a regular proof of purchase (till receipt or invoice).
the warranty expires in the instance where the Acquirer uses the appliance in an inappropriate and/or in such a way that goes against
5) EXPIRY:
0,5
/
the details in the "Instruction Manual" supplied by the Manufacturer, or in the instance where the defect is owing to the inexperience of the
Acquirer or an accident.
9
the Manufacturer is exempt from all responsibility from harm caused to the Acquirer in terms of lack of or reduced
6) RESPONSIBILITY:
performance owing to conformity defects.
72
/
the fees relative to the work force and materials necessary to restore the appliance are charged to the Manufacturer. The fees and
7) FEES:
delivery methods are to be agreed upon with the Authorised Supplier.
2800
/
5
Rights reserved with regards the "Instruction Manual" remain with the Manufacturer. No parts of the present manual, in full or in part, may be
/
copied and/or passed on in any way, without written authorisation from the Manufacturer. All the brands mentioned belong to the respective
owners.
+5 ÷ +40 / 5 ÷ 95
12,5
FIELD OF OPERATION
191x414x392
PLACE OF OPERATION
INTENDED USE
OPERATORS
AUTHORISED USE
The appliance was designed and manufactured exclusively for the aim as described in
operators and appliance efficiency at all times, any other use is completely forbidden.
IT IS COMPLETELY FORBIDDEN TO OPERATE THE APPLIANCE IN ENVIRONMENTS PRONE TO EXPLOSIONS AND/OR WHERE COMBUSTIBLE SUBSTANCES ARE
Gentilin Giuseppe
PRESENT (E.G. WOOD GRAINS, FLOUR, SUGAR AND GRANULES).
DANGER OF BURNS UPON ACCIDENTAL CONTACT WITH SINGLE-CYCLINDER PUMPING ASSEMBLY AND ELECTRTIC MOTOR. WARNING – RESIDUAL RISK
(SEE PARAGRAPH 22).
THE MACHINE MUST BE USED IN COMPLIANCE WITH LEGISLATION GOVERNING EMISSIONS (NOISE) IN FORCE IN THE COUNTRY OF USE.
DURING USE, ENSURE THAT UNAUTHORISED PERSONS DO NOT COME WITHIN PROXIMITY OF THE APPLIANCE.
THE APPLIANCE MUST BE KEPT OUT OF THE REACH OF CHILDREN.
IT IS STRICTLY FORBIDDEN TO USE THE MACHINE OUTDOORS.
INCORRECT USE OF THE APPLIANCE OR USE WHICH DIFFERS FROM THAT SPECIFIED IN PARAGRAPH 10 IS FORBIDDEN.
(FIG. 2)
.
THE USE OF UNSUITABLE AIR PIPES (EXTENSIONS), CONNECTIONS AND UTENSILS OR THOSE WHICH DO NOT CONFORM WITH CURRENT LEGISLATION IN
FORCE ARE COMPLETELY FORBIDDEN.
IT IS FORBIDDEN TO LIFT THE APPLIANCE WITH CRANES AND/OR LIFTING DEVICES.
IT IS FORBIDDEN TO DIRECT COMPRESSED AIR JETS AT PERSONS AND/OR ANIMALS.
IT IS FORBIDDEN TO USE THE APPLIANCE TO MOVE AND/OR LIFT PERSONS, ANIMALS OR OBJECTS.
, in order to guarantee
IT IS FORBIDDEN TO MOUNT THE APPLIANCE.
IT IS FORBIDDEN TO TOW THE APPLIANCE USING ANY TYPE OF MEDIUM AND/OR VEHICLE.
IT IS FORBIDDEN TO MANUALLY MOVE THE APPLIANCE UPHILL AND/OR DOWNHILL WHERE DANGEROUS INCLINATIONS ARE PRESENT.
The machine can be carried by an operator using the handle
THE MACHINE MUST BE MOVED BY AN OPERATOR IN OBSERVANCE OF THE REGULATIONS GOVERNING THE "MANUAL HANDLING OF LOADS" IN ORDER TO
PREVENT UNFAVOURABLE ERGONOMIC CONDITIONS THAT COULD CAUSE BACK INJURY.
The machine is packed by the Manufacturer on a pallet, fixed with straps and covered by a cardboard box and can only be moved using a fork lift
truck or a transpallet. The pack contains 1 compressor and 1 instructions manual.
Once the package has been placed on the floor on a flat surface which ensures stability, proceed with unpacking; remove the appliance from its
packaging as per the instructions provided in
PLEASE DISPOSE OF THE PACKAGING DIVIDING IT UP ACCORDING TO THE VARIOUS WASTE MATERIALS AND IN COMPLIANCE WITH LEGISLATION
CURRENTLY IN FORCE IN THE COUNTRY OF USAGE.
The appliance must be placed in a work place which satisfies the characteristics described in
a flat surface which ensures stability with regards to overall dimensions and weight
IN ORDER TO ENSURE A SAFE WORKING ENVIRONMENT FOR AUTHORISED OPERATORS, WE RECOMMEND PLACING THE APPLIANCE AT A MINIMUM
DISTANCE OF 1 m FROM OTHER OBJECTS/ENTITIES.
In the instance where the appliance is not to be used for an extended period of time, it must be stored in a safe place, with
suitable temperature and air humidity values, where it is protected from dust. Before storing the appliance, we recommend
draining moisture from the air tank
THE POWER SUPPLY NETWORK TO WHICH THE APPLIANCE IS CONNECTED MUST CONFORM TO THE LEGISLATION CURRENTLY IN FORCE IN THE COUNTRY
OF USAGE, CONFORM TO THE TECHNICAL SPECIFICATIONS PROVIDED IN PARAGRAPH 2 AND BE EQUIPPED WITH A SUITABLE "PLANT EARTHING" SYSTEM
ALL MATERIALS USED FOR ELECTRICAL CONNECTION MUST BE SUITED TO THE INTENDED USAGE, LABELLED WITH "CE" IF SUBJECT TO THE LOW VOLTAGE
DIRECTIVE 2006/95/CE AND CONFORM TO THE REQUIREMENTS AS SPECIFIED IN THE LEGISLATION CURRENTLY IN FORCE IN THE COUNTRY OF APPLIANCE
USAGE.
DISREGARD FOR THE ABOVE DESCRIBED WARNINGS MAY LEAD TO IRREPERABLE DAMAGE TO THE APPLIANCE ELECTRICAL SYSTEM AND SUBSEQUENTLY
WARRANTY EXPIRY.
THE MANUFACTURER DECLINES ANY RESPONSIBILITY FOR FAULTS OR ANOMOLIES WITH APPLIANCE OPERATION CAUSED BY ELECTRICAL POWER SURGES
IN ADDITION TO TOLERANCES BY THE SUPPLY ENTITY (VOLTAGE ± 10%, FREQUENCY ± 2%).
;
WHERE NECESSARY, CONNECT THE APPLIANCE EXCLUSIVELY TO THE ELECTRICAL SUPPLY GENERATOR WITH POWER GRTEATER THAN THE INSTALLED
ELECTRICAL POWER (SEE PARAGRAPH 2), IN ORDER TO SUPPORT THE POWER-DRAW AT START-UP.
1) Connect the utensil to the air pipe (extension);
2)
Connect the air pipe (extension) to the appliance air outlet spigot
AIR PIPES (EXTENSION), CONNECTIONS AND UTENSILS WHICH CONFORM TO THE MANUFACTURER'S INSTRUCTION MANUALS MUST BE USED.
THE USE OF UNSUITABLE AIR PIPES (EXTENSIONS), CONNECTIONS AND UTENSILS AND/OR THOSE WHICH DO NOT COMPLY WITH LEGILATION CURRENTLY
IN FORCE IS STRICTLY FORBIDDEN.
THE MANUFACTURER DECLINES ANY RESPONSIBILITY FOR DAMAGE TO PERSONS, ANIMALS AND OBJECTS CAUSED BY THE INOBSERVATION OF THE
ABOVE DESCRIBED WARNINGS.
(cont.)
FIG. 3
Via delle Tezze, 20/22 - 36070 Trissino (VI) ITAL Y
Tel. +39 0445 962000 - Fax +39 0445 491412
commerciale@gentilin.it - www.gentilin.it
Carrying handle
1)
Air conveyor
2)
19
ON (I) – OFF (O) switch
3)
Pressure switch
4)
Safety valve (set to 10.5 bar)
18
5)
Air tank
6)
Power plug and cable
7)
17
8)
Feet
9)
Outlet pressure regulator
16
10)
Tank outlet gauge
11)
Air outlet spigot
15
12)
Air filter
Electric motor
13)
Condensate pump
14)
Pump/Tank connection pipes
15)
14
Non-return valve
16)
Tank pressure gauge
17)
Fixed cooling fan protective net
18)
Single-cylinder pumping assembly
19)
9- RIGHTS RESERVED
10- INTENDED USE
Industrial, handicraft and civil.
Interior locations with sufficient lighting, ventilation, with temperature and air humidity values as per details provided
in
Paragraph 2
, in compliance with legislation governing health and safety in the work place in force in the country of
usage. The appliance must rest on a surface that ensures the appliance is stable with respect to its weight and
overall dimensions
(see Paragraph 2)
.
WARNING! THE APPLIANCE MUST BE KEPT OUT OF REACH OF CHILDREN.
Compressing air (no oil) to be used with suitable pneumatic utensils according to current legislation in force (E.g.
blowing, pumping, washing, veneering and sandblasting, etc...).
An authorised operator with professional, technical skills as described in
11- INCORRECT USE
12- TRANSPORTATION AND MOVEMENT OF THE APPLIANCE
(FIG. 3 - Ref. 1)
.
13- PACKAGING
14- UNPACKING
Paragraph 12
.
15- LOCATION
16- STORAGE
(FIG. 1 - Ref. 14)
.
17- ELECTRICAL CONNECTION
The machine can be connected to the mains electrical supply by plugging the power cable
special socket.
18- AIR PIPE (EXTENSION) AND UTENSILS CONNECTION
(FIG. 1 - Ref. 11).
Right side
GENTILIN SRL
Paragraph 6
.
Paragraph 10
; in order to ensure the safety of authorised
Paragraph 10
; it must be placed on
(see Paragraph 2)
.
(FIG. 1 - Ref. 7)
into the
1

Advertisement

loading

Summary of Contents for Genlilin B110/05

  • Page 1 , in compliance with legislation governing health and safety in the work place in force in the country of PLACE OF OPERATION usage. The appliance must rest on a surface that ensures the appliance is stable with respect to its weight and The Manufacturer declares that the compressors B110/05 overall dimensions (see Paragraph 2) WARNING! THE APPLIANCE MUST BE KEPT OUT OF REACH OF CHILDREN.
  • Page 2 19- SAFETY DEVICES ADOPTED 27- APPLIANCE DEACTIVATION At the end of operations, switch off the appliance as follows: (FIG. 1 - Ref. 5) a certified safety valve (set to 10.5 bar), installed to the pneumatic system, under the pressure switch. It tackles 1) SAFETY VALVE Switch off the appliance using the “ON (I) -OFF (0)”...