RENEWABLE HEATING & COOLING TECHNOLOGY INTRODUCTION This manual This manual includes the necessary information to or damage safely install and maintain your Heat Pump. Please read this manual carefully before you operate the unit. The Heat Pump The swimming pool heat pump is one of the most economical ways of heating your swimming pool efficiently.
RENEWABLE HEATING & COOLING TECHNOLOGY -Be sure to read the following WARNING before installing the unit. -After reading these instructions retain for future reference. WARNING Installing the Unit. Incorrect installation could cause injury due to fire, electric shock or water damage. If in doubt consult your local dealer or a qualified installer.
RENEWABLE HEATING & COOLING TECHNOLOGY CONTENTS Before starting the installation, please make sure that all items are found inside the box. The Unit Box Item Image Image Item Swimming Operation pool heat pump Installation Manual Accessories 1(set) Page 4...
RENEWABLE HEATING & COOLING TECHNOLOGY INSTALLATION Installation guidelines The following information is for guidance only. Locating the Unit The unit should be located on a solid, flat, horizontal surface. Ensure 3 metres of free air flow to the discharge panel and 1metre to the inlet panel. Ensure adequate access to the controller and for maintenance purposes.
The Electrical supply must correspond to that indicated on the appliance. All supply cables have to be sized according to the appliance power and installation requirements. Please refer to below table: Heat Pump Cable Size LCSPI-120/150 LCSPI-170 3x .0mm LCSPI-210 5 2.5 5 2.5 LCSPI-250 5 2.5...
RENEWABLE HEATING & COOLING TECHNOLOGY Features and functions Basic controller functions The basic controller functions are: Turning the heat pump ‘ON’/’OFF’. 24 hour time clock. Timer ‘ON’ and timer ‘OFF’. Parameter adjustment User interface NEVER LET THE DIGITAL CONTROLLER GET WET. THIS MAY CAUSE AN ELECTRIC SHOCK OR FIRE. NEVER PRESS THE BUTTONS OF THE DIGITAL CONTROLLER WITH A HARD, POINTED OBJECT.
Page 11
RENEWABLE HEATING & COOLING TECHNOLOGY adjust button >Turn pages up and down to check,modify parameters. >Combining with to query and change parameters. >Under unit ON status,press to set temperature in current mode. Timer button Press this button for 10 seconds to set clock. Press this button to enter into Timer ON/OFF setting mode,combing with and buttons to set 2 groups...
Page 12
RENEWABLE HEATING & COOLING TECHNOLOGY >After setting Timer 1 ON “hour” digit,press again to enter into Timer 1 ON “minute” digit which will flash, then press buttons to set value for Time 1 ON “minute” digit. >After setting Timer 1 ON “minute” digit, press again to enter into Timer 1 OFF “hour”...
RENEWABLE HEATING & COOLING TECHNOLOGY PARAMETER CHECKING AND ADJUSTMENT Unit Status Query Table Code Parameter Name Coil temp Return gas temp Exhaust gas temp Ambient temp Outlet water temp Return water temp Reserved Compressor current Opening of the EEV Reserved ~E6 Error code display Parameter settings...
RENEWABLE HEATING & COOLING TECHNOLOGY ERROR CODES When an error occurs or the protection mode is set automatically,the wired controller will display an error code as below. Possible reasons Code Failure Remedy 1)sensor open circuit 1)Check the sensor connection Er 15 Inlet water temp sensor 2)sensor short circuit 2)Replace the sensor failure...
RENEWABLE HEATING & COOLING TECHNOLOGY MAINTENANCE To protect the paintwork, avoid leaning or putting objects on the shell. External Heat Pump parts can be wiped with a damp cloth and domestic cleaner. (Warning: Never use cleaning agents containing sand, soda, acid or chloride as these can damage the surfaces.) To prevent blockages in the titanium heat exchanger, ensure that the system incorporates a water and filter treatment facility.
RENEWABLE HEATING & COOLING TECHNOLOGY WHEN CARRYING OUT ANY MAINTENANCE ENSURE ADEQUATE PRECAUTIONS ARE TAKEN TO PREVENT AN ELECTRIC SHOCK . The hints below are for guidance only. If you cannot solve the problem, consult your installer/local dealer. The Heat pump will not run. Please check: There is a supply voltage (tripped fuse, power failure).
Page 17
RENEWABLE HEATING & COOLING TECHNOLOGY with relevant local and national legislation. Units must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring that this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information.
Need help?
Do you have a question about the LCSPI-120 and is the answer not in the manual?
Questions and answers