  • Page 1 ‘Predix’ Microwave Barrier Detection System Installation Guide and Operating Manual English version (19.02.2014)
  • Page 2: Package Contents

    Umirs Europe Ltd. Predix Dear Customer! Thank you for choosing our product! Before installation, please read the Operating Manual carefully, so you can take safe and full advantage of all features of the product. This manual contains information about the design, operation, application and technical parameters of the ’Predix’...
  • Page 3: Intended Use

    Umirs Europe Ltd. Predix INTRODUCTION This operating manual contains information on the function, assembly, adjustment, operating principle, technical features and composition of the ’Predix’ Microwave Barrier Detection System and its implementation versions (hereafter referred to as ‘the detector’), as well as its deployment and operation.
  • Page 4: Selecting The Installation Location

    Umirs Europe Ltd. Predix operating frequency also contributes to the narrow width of the detection zone. A sample view of the detection zone profile of a 300 m-long segment is shown in Figure 1.1. Figure 1.1 – Sample view of the detection zone profile...
  • Page 5: Mounting The Detector

    Umirs Europe Ltd. Predix Comment – No requirements are shown in respect of the area for the limits of non-radio transparent (metal, ferroconcrete and so on) walls and barriers. The presence of nearby walkways, bikeways, roadways, railways, etc., forested tracts, and large, immovable objects and structures must be at a distance from the detector of no less than twice the width of the exclusion zone itself.
  • Page 6 Umirs Europe Ltd. Predix above the ground. There has to be provided the facility to shift the detector units along the support simply in case of seasonal adjustments. The initial height at which the detector units should be positioned before further adjustment is 0.9 m from the ground surface to the center of the unit.
  • Page 7 Umirs Europe Ltd. Predix INSTALLING MULTIPLE DETECTORS AT ONE SITE Where several detectors are installed adjacently with the intent to prevent penetration of the barrier at the so-called “blind zones” in the immediate vicinity of the detector units, a segment coverage overlap of at least 3 m should be established.
  • Page 8 Umirs Europe Ltd. Predix Figures 2.1 – Variants of configuration of adjacent overlapping segments Figure 2.1.1 Figure 2.1.2 Figure 2.1.3 - 8 -...
  • Page 9: Preliminary Set-Up

    Umirs Europe Ltd. Predix PRELIMINARY SET-UP The detector has two systems for the determination of proper threshold levels: “automatic” and “manual”. In the automatic system, the processor determines the optimal threshold levels for the detection of intruders penetrating the detection zone on a ground surface. In the manual system, the optimal threshold levels are explicitly specified by the operator.
  • Page 10: Frequency Adjustment

    Umirs Europe Ltd. Predix DETECTION SPEED ADJUSTMENT An important feature of the processing algorithm of the detector is its ability to evaluate the likely maximum speed at which an intruder could be expected to penetrate the detection zone in relation to the actual penetration speed of the intruder. The specification of the associated evaluation parameter is made by the user, depending on the physical characteristics of the protected area.
  • Page 11 Umirs Europe Ltd. Predix signal about the fault, namely: lack of signal at the entry of the receiver unit , outage of the transmitter unit or receiver unit , flashing of the receiver unit by powerful sources of radio noise and in several other cases for more than 30 s;...
  • Page 12: Technical Specifications

    Umirs Europe Ltd. Predix TECHNICAL SPECIFICATIONS Specification Value Detection zone length 10-400 m Minimum required level of signal received at maximum length of the 8 dB DETECTION ZONE Minimum detection zone height for a protected segment length of 2.5m 300m Range of detection speeds 0.1-10.0 m/s...
  • Page 13 Umirs Europe Ltd. Predix Table 2.1 – Connections of the receiver unit Color of the output Purpose of output Brown Plus supply White Minus supply Shield of the cable (gen) RS-485 Green (A) Yellow (B) Grey alarm output (OC) Pink alarm output (OC) Table 2.2 –...
  • Page 14 Umirs Europe Ltd. Predix Programming procedure of the „Predix” microwave detector For the programming You will need: 1 personal computer (Windows XP or Windows 7 OS) 1 Umirs USB-RS485 converter 1 USB -mini USB cable 1 software The latest version of the software can at all times be downloaded from www.umirs.eu...
  • Page 15 Umirs Europe Ltd. Predix Choose a directory, where You would like to install the software: press NEXT to continue. Choose a folder in the START menu for the shortcut of the software. press NEXT to continue. You can choose to create a desktop icon for a quick access to the software.
  • Page 16 Umirs Europe Ltd. Predix Installation in progress……this takes up a few seconds. The installation is successfully finished. press „Finish” to exit the installation wizard. After the installation carry out the configuration. - choose a language. - press NEXT. Choose „Radar –based barrier” function You can choose to protect the software with a password.
  • Page 17 Umirs Europe Ltd. Predix Here You can see the current settings. press DONE to finish the configuration and continue The configuration is in progress… this can take up a few seconds. The configuration is successfully finished Press EXIT to continue.
  • Page 18 Umirs Europe Ltd. Predix Starting the programming procedure: Click on the „Predix” icon. (in case of Windows 7 OS an error-massage can appear, that the software is already running: in this case close the error-massage and run the program as system administrator) The authorization-window appears.
  • Page 19 Umirs Europe Ltd. Predix Programming the Transmitter: Carry out the configuration of the Transmitter first. The factory default network address of every Predix Transmitter is „1”. Start the communication between the device and the computer by pressing Start. If the connection happened, we can se the factory settigns of the Transmitter on the „System”...
  • Page 20 Umirs Europe Ltd. Predix To carry out the programming of the transmitter go to the „Transmitter” bookmark in the bottom of the window. Choose „Modify” to start the programming procedure. You can set the operating frequency channel of the current transmitter between 1 and 250.
  • Page 21 Umirs Europe Ltd. Predix The following parameters are shown here: Firmware version Type of the connected device: transmitter or receiver Serial nmber of the device Maximal operating range Temperature (this function is only available at devices with firmware version 3.9T/R or later) Power supply voltage (this function is only available at devices with firmware version 3.9T/R or...
  • Page 22 Umirs Europe Ltd. Predix In auto mode: -1 dB -15dB In the third line choose the detection speed. There are 3 options: –low – medium – high - 22 -...
  • Page 23 Umirs Europe Ltd. Predix The receiver also has a „Disarmed” function (available on devices with firmware version 3.9 or later). This way the detector gets disabled with the power supply and the status of the output relay staying normal. Switching to „Disarmed” state is also indicated by the LED on the transmitter’s...
  • Page 24 Umirs Europe Ltd. Predix Signaling: Configuration: (for later activation) Outputs an LED’s: To change the settings choose „Modify” Alarm relay: here You can activate the alarm relay without an actual alarm to check the communication between the detector and the alarm panel...