FloodMaster RS-094-MK4 Installation Manual

Plug-in power-vent gas water heater

Advertisement

Quick Links

FOR CONVENTIONAL PLUG-IN POWER-VENT GAS WATER HEATERS
Operation and Installation Instructions for FloodMaster
RS-094 Water Heater Leak Detection Alarm/Shut-Off
Systems with Electrical Plug Interrupter
The RS-094 series of Feed Water (Water Heater) Leak Detection and Shut-Off Systems
is designed to monitor and respond immediately to water leaks. When a sensor comes
in contact with as little as a 1/16" of water (or any other conductive liquid), it will
automatically sound an audible alarm and close the valve to shut down the water feed
line, thus mitigating damage caused by an undetected water leak. This kit also provides
output signal capabilities to automatically kill electricity to the Water Heater Power Vent
when a leak is detected. Installation of this device should only be performed by appropriately licensed and certified installers.
OPERATION:
In the event the system activates, locate the source of the leak, remove the sensor from the water and dry the metal contacts on the
bottom. Correct the problem causing the leak and replace the sensor in the desired leak detection location once again as required. Press
and release the reset button on the receiver to open the valve and begin the flow of water again. The green Power indicator light on the
receiver will flash once to confirm the reset.
RS-094-MK4 Kit Pre-Wired at the Factory
RS-094
1 2 3 4 5 6 7 8 9
POWER
SUPPLY

INSTALLATION INSTRUCTIONS:

(FloodMaster recommends that installations be completed by a licensed plumber to ensure that all local code requirements are followed).
1. Turn off the water supply feed line to the water heater. Confirm that the Power-Vent Water Heater is unplugged
from the electrical supply.
2. Thread the valve body into the feed water line after the manual shut-off. Apply pipe sealant or Teflon
to the NPT threads and tighten.
3. The receiver connector comes pre-wired with basic connections to the power supply, sensor and electrical plug
interrupter. Using an appropriate screwdriver, make any additional electrical connections as may be desired for
output contacts or additional sensors per the diagram provided. (Note: Additional sensors can be connected to
either 6 & 7 or 8 & 9, as wiring space allows.) Snap the terminal wiring block into the receiver housing at the
mating slot provided.
(Continued – See reverse.)
Reliance Detection Technologies, LLC
27 Business Park Drive, Branford, CT 06405
Installation Manual
1 2
RelianceDetection.com
All specifications are subject to change without notice.
DANGER – Electrocution Hazard
For use in dry locations only. Always unplug the relay module
before servicing or installation. For continued protection against
electric shock, plug into grounded outlets only and do not remove
the ground pin.
DANGER – Risque d'électrocution
À utiliser dans des endroits secs uniquement. Toujours débrancher
le module de relais avant l'entretien ou l'installation. Pour une
protection continue contre l'électrocution, uniquement brancher à
des prises mises à la terre et ne pas retirer la broche de terre.
tape
®
888-771-4929
Tel: 203-488-2684
Fax: 203-481-5036
RS-094-MK4
info@RelianceDetection.com
ECN # 9508, 03/2016, MF105, REV A

Advertisement

loading

Summary of Contents for FloodMaster RS-094-MK4

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS: (FloodMaster recommends that installations be completed by a licensed plumber to ensure that all local code requirements are followed). 1. Turn off the water supply feed line to the water heater. Confirm that the Power-Vent Water Heater is unplugged from the electrical supply.
  • Page 2 Installation Manual RS-094-MK4 FOR CONVENTIONAL PLUG-IN POWER-VENT GAS WATER HEATERS 4. Secure the valve body in one hand and snap the receiver into place on the valve body mounting pad. (Note: Improper alignment of the valve stem may interfere with proper receiver mounting. If any resistance is encountered, confirm that the witness mark on the valve stem is in alignment with the ports of the valve.