Officine Gullo CVCS4G Instructions For Installation And Use Manual

Pasta cooker for residential and professional use

Advertisement

CVCS4G
CVCS6G
CVS4G
CVS6G
PASTA COOKER FOR
RESIDENTIAL AND PROFESSIONAL USE
INSTRUCTIONS
for installation and use

Advertisement

Table of Contents
loading

Summary of Contents for Officine Gullo CVCS4G

  • Page 1 CVCS4G CVCS6G CVS4G CVS6G PASTA COOKER FOR RESIDENTIAL AND PROFESSIONAL USE INSTRUCTIONS for installation and use...
  • Page 2 14. In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry out any repairs, which must be done exclusively by an authorized service center. Request the use of original spare parts only. Failure to comply with the above recommendations may compromise the appliance’s safety Officine Gullo...
  • Page 3 FIG.A CVS4G - CVS6G 1200 1200 1600 A. Data plate C. Gas Connection R 1/2GM Officine Gullo...
  • Page 4 FIG.B CVSC4G A. Data Plate C. Gas Connection ISO 7-1 R1/2GM D. Water connection R 1/2GM E. Water drainage R 1GF Officine Gullo...
  • Page 5 FIG.B2 CVSC6G A. Data Plate C. Gas Connection ISO 7-1 R1/2GM D. Water connection R 1/2GM E. Water drainage R 1GF Officine Gullo...
  • Page 6 FIG.C   Bypass Piezoelectric device FIG.D 1. Bride 2. Pilot 3. Thermocouple   4. Spark plug Injector Officine Gullo...
  • Page 7 FIG.E WATER FILLING TAP   Officine Gullo...
  • Page 8 Power terminal block alimentazione alimentacion 7. Power terminal block Sonda di livello Pegelsonde Sonde de niveau Level Probe Sonda de nivel Spia rossa Kontrolleuchte rot Lampe témoin rouge Red warning light Piloto rojo 8. Level Probe 9. Red warning light Officine Gullo...
  • Page 9 WHAT TO DO IN THE EVENT OF A BREAKDOWN ......19 PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT ....19 GOING TO BE USED FOR SOME TIME ..........19 MAINTENANCE (only for qualified personnel) ......... 19 INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ....20 Officine Gullo...
  • Page 10: Declaration Of Compliance

    ISO R7 TOT. kW CVS4G 40 x 70 x 29h R 1/2”GM CVS6G 60 x 70 x 29h R 1/2”GM CVCS4G 40 x 70 x 90h R 1/2”GM R 1GF R 1/2”GM CVCS6G 60 x 70 x 91h 13,95 R 1/2”GM R 1GF R 1/2”GM...
  • Page 11: Checking For Adequate Ventilation

    All our appliances undergo careful testing: the type of gas, the operating pressure and the category are indicated on the data plate. Officine Gullo...
  • Page 12: Checking Heat Output

    Connection with natural gas H G20 The connection pressure for natural gas is 20 mbar. Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied by the manufacturer. Officine Gullo...
  • Page 13 Min. output adjustment 1/100 mm adjustable Pilot Injector Consumption kg/h 0,710 kg/h 0,699 m³ st./h 0,952 Primary air h =mm CVCS4G Burner 9,5 kW Burner Injector 1/100 mm Min. output adjustment 1/100 mm adjustable Pilot Injector Consumption kg/h 0,749 kg/h 0,738 m³st./h 1,005...
  • Page 14 Examine the flame of the pilot burner; it must lap the thermocouple and be blue, • otherwise examine the nozzle of the pilot burner. Check the lighting and flame of the main burner. • • We urge the user to follow the instructions when using the appliance. Officine Gullo...
  • Page 15: Maintenance

    The drain piping must be connected to a suitable drain and be compliant with the norms. The piping must be connected in such a way as to avoid contractions or siphons. Drainage of the water is free, therefore it is essential that the drain is lower than the outlet of the piping. Officine Gullo...
  • Page 16: Water Filling

    The burner will remain off 5) Turn the gas knob to the   until the water reaches the minimum level probe. 6) To set the burner to the minimum, turn the gas knob to the position Officine Gullo...
  • Page 17: Turning Off The Appliance

    NOTE: the filling phase is monitored by the system through the TIME-OUT. OBSERVATIONS AND ADVICE Always keep the water level checked. ATTENTION! Do not start up the appliance without water. Use the appliance only under surveillance. Officine Gullo...
  • Page 18: Cleaning And Maintenance

    All the chromium-plated surfaces should be cleaned, where necessary, with a soft, possibly micro-fiber cloth, combined with metal polishing products, if required. Do not use abrasive pads. Officine Gullo...
  • Page 19 Turn off the gas tap and clean the appliance as specified above. MAINTENANCE (only for qualified personnel) Any kind of maintenance must only be done by qualified personnel. Before carrying out maintenance,remove the plug or switch off the switch above the appliance. Officine Gullo...
  • Page 20: Instructions For Discharging Gas Emissions

    INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS Type “A” Appliances (See data plate) Type “A” appliances must discharge the products of combustion into extractor hoods or similar devices connected to and efficient chimney, or directly outside. (Natural Discharge) Fig.1. If there is no hood, as an alternative, an air extractor connected directly to the outside is acceptable, (Forced Discharge) Fig.2.
  • Page 24 INTERNATIONAL V 2.1 - 9.17 OFFICINE GULLO S.R.L.: via della Torricella 29, 50012 Antella - Bagno a Ripoli (FI) Tel. +39 055 6560324 / 621807 - Fax: + 39 055 620670 - info@officinegullo.com WWW.OFFICINEGULLO.COM...

This manual is also suitable for:

Cvcs6gCvs4gCvs6g

Table of Contents