Page 3
Wireless Keypad PU-R ................... 67 ROPERTIES OF THE WIRELESS EXPANDER F ................. 70 ROPERTIES OF THE WIRELESS EXPANDER F240................71 ROPERTIES OF THE WIRELESS EXPANDER ........................71 ETECTORS PROPERTIES ....................... 73 ROPERTIES OF CONTROL DEVICES ..................75 ROPERTIES OF OUTPUT MODULES GROUPS ......................
The Wireless System “Strelec” is designed to protect the sites where the use of wired systems is prohibited, unacceptable or economically unfeasible. PU-R contains in its memory the full configuration of the Strelec, including its to- pology and the composition of the wireless network, as well as settings of both Control Panels and slave devices of the Strelec.
PU-R can be connected through the wireless interface only to the two-antenna expanders which firmware version is higher that 2. PU-R can be connected to the one-antenna expanders and the expanders with the first version of the firmware only through the interface RS-232. The firmware version can be updated at the manufacturer’s facto-...
Charging of the discharged storage battery lasts about 10 hours; ATTENTION! To power supply PU-R, use only the lithium batteries 9V, 1.2 Ah such as Energizer NO L522, Ultralife U9VL-J, EEMB ER9V! When using alkaline batteries, PU-R service life will significantly drop (roughly 2-4 times).
BUT- 2 PU-R PU-R Design and control Wireless Keypad PU-R TONS 2 PU-R DESIGN AND CONTROL BUTTONS 2.1 Outward appearance The front panel of PU-R has: Bi-color back- light LCD screen (page 9) Alarm indicator (a red indicator, glowing at any...
Strelec (a user has to enter their code). Pushing any button will illuminate the keypad and the screen. If backlit illumina- tion is off in the adjustment options of PU-R, press and hold any button to turn it...
BUT- 2 PU-R PU-R Design and control Wireless Keypad PU-R TONS 2.3 LCD screen Integral status of Strelec Security integral status of partitions all the partitions – fire alarms – all the partitions are armed – security alarms – all the partitions are not armed –...
4 Screen menu Wireless Keypad PU-R 3 PRE-STARTING PROCEDURES 3.1 Delivery set The delivery set includes: Lithium battery 9 V, 1.2 Аh Programming cable RS-232 for connec- tion to the expander Adapter DB-9F/DB-9F "Male changer" for connection to a PC ...
Wireless Keypad PU-R 3.3 Connection through the interface RS-232 In order to program the wireless expander of the Strelec by using PU-R, connect the wireless expander with PU-R by the cable delivered in the set. While programming through the interface RS-232, PU-R can be power supplied from both the battery and external source.
4 Screen menu Wireless Keypad PU-R PU-R can be connected to the wireless expander RROP through the interface RS- 232 by using three connecting conductors instead of the cable. 4 SCREEN MENU 4.1 Main window and menu navigation STRELEC...
Page 13
‹ › can be pushed ‹ › Меню When the screen button is pushed, the menu of PU-R is displayed. Control System state Events protocol Back Select ‹ › Use the button to go up/down in the menu.
Page 14
If no buttons are pushed on the keypad, the main window of the screen will occur in 2 min. When power supplied from the battery, PU-R will switch into the mode of low en- ergy consumption (saving the battery) in 8 seconds in the case if no buttons are...
Wireless Keypad PU-R 4.3 Menu "Settings" Menu Settings Code ► Menu is used for selecting PU-R options. The code that should be entered can be either an engineer’s or an user’s. ►Clock Setting the current date and time Changing the option in the PU-R will cause setting the clock in the wireless expander –...
Page 17
"Off" – backlight is off, however it can be enabled when any button is pushed and hold for a while. Backlight illumination consumes a significant amount of current, so keeping backlight off can safe the battery life, in the case PU-R is power supplied from the battery. ►Contrast ‹...
Configuration menu of users’ properties Users’ codes can be added/erased/altered in the menu. The lists of global partitions that users are capable of controlling from PU-RВ can also be changed. An engineer is capable of changing characteristics of any users, while users can alter only their codes.
Page 19
►Read properties To read all the properties of Strelec should be done when it is necessary to update the configuration of Strelec, stored in the memory of PU-R. The order of reading is listed in the paragraph 5.5 (page 40).
Page 20
4 Screen menu Wireless Keypad PU-R The wireless Keypad PU-R and different devices of the systems transmitting messages belong to the system devices. The properties of system devices are described in the paragraph 8.8 (page 76). ►Global partitions Text descriptions (descriptors) are allocated to the global partitions of Strelec.
Wireless Keypad PU-R 4.5 Menu "System state" Menu System state ‹ › Main window of PU-R State Menu is designed to display the current condition of all the devices and partitions of Strelec. State of wireless expanders Wireless expanders of Strelec are listed in the state window, with their status writ- ten in front of every expander.
Page 22
State Press to view state of the device ‹ › When the screen button has pressed, State PU-R will receive from the wireless expander and display a state of the device selected. State Norma Link Norm Back Refresh List and state of global partitions To view states of global partitions, select the option “Global partitions”...
The menu is intended to view the events protocol of Strelec. ►Show protocol ‹ › Main window of PU-R PU-R can read the events protocol from the memory of the wireless expander – network coordinator. The event line con- 00:36 Arming...
4 Screen menu Wireless Keypad PU-R The events, that have to be displayed when viewing the protocol, will be marked by a Duress dot inside the block. To select a filtering op- Arm/Disarm tion, select a line with the event and press Alarm ‹...
4.8 Menu "Control" Menu Control Code ► ‹ › Main window of PU-R Code ► The menu is designed to execute some control actions. ►Remote control Control of slave devices –...
Page 26
Turn off indication Control of detectors sensitivity Change sensitivity If a command is accomplished successfully, PU-R will confirm it by the message "Control complete". ►Output modules groups Control menu of status of executive device groups While programming, executive devices are assigned to one of eight groups.
Page 27
4 Screen menu Wireless Keypad PU-R – WEx 0 0.1 Ikar-R To bypass a detector, select it in the to- 0.2 Aurora-R pology of the devices and press the screen Back ‹Off› button If the action is executed successfully, the assignment of the screen button will be ‹...
5.5 (page 40) 5.6 (page 42) Configuration of the system using the keypad PU-R is performed in the similar way to the configuration executed by the software "Strelec" (file WirelEx). Initial programming of Strelec by the keypad PU-R is described in the paragraph 5.2 (page 29).
5 Configuration of Strelec Wireless Keypad PU-R 5.2 Initial configuration performed by the keypad Connect the keypad to the wireless expander, which is supposed to be the network coordinator as well, through the interface RS-232 (paragraph 3.3, page 11). Turn the keypad and the wireless expander on.
Page 30
5 Configuration of Strelec Wireless Keypad PU-R 2. If necessary, change the radio-frequent properties of the wireless system – Select "Frequency range" (434 МHz or 868 МHz), – Select "Channel number" (from 1 to 6), – Change "System code" (the first two digits are from 00 to 99).
Page 31
5 Configuration of Strelec Wireless Keypad PU-R – Devices Pay attention that those slave devices, ? 0.1 Aurora-R that are just added and therefore, not programmed yet, will be marked by "?" Properties Action in the topology tree. Sign of the devices that...
Page 32
5 Configuration of Strelec Wireless Keypad PU-R 4. Programming of devices Connect the keypad to the wireless expander, functioning as a network coordi- nator. In the window of devices topology, select the wireless expander WEx 0 (or WEx 0 for wireless expanders WExF and WExF240) and select the action "Program".
Page 33
ATTENTION! If there are several keypads PU-R located in Strelec or while using the software Strelec, read the configuration of the system by other keypads or the utility file "WirelEx" just after one keypad has been programmed.
5.3 Registration of PU-R in the wireless expander In order to operate through the wireless interface, PU-R is required to be registered in the wireless expander functioning as a network coordinator. For registration, connect PU-R to the wireless expander through the interface RS-232.
Action If there are several PU-R in the system, the comment “activated” will occur in the line of that PU-R that is currently connected to the wireless expander. If PU-R is required to be removed from the memory of the wireless expander, ‹...
Page 36
‹ Yes › Press the screen button While changing properties of a remote expander, the window, requesting "Pro- gram remotely?", will occur (if PU-R is Program connected to WEx 0). Make sure that the remotely wireless expander is turned on and press ‹...
Page 37
5 Configuration of Strelec Wireless Keypad PU-R – Devices Select a slave device, which features 0.1 Aurora-R should be changed, in the network to- 0.2 Ikar-R pology tree. Properties Action ‹ Properties › Press the screen button Make necessary changes in the window displaying properties of a slave device.
Page 38
5 Configuration of Strelec Wireless Keypad PU-R Changing features of system devices Features of system devices are stored in the memory of the wireless expand- er, from where every system device has been reading them during the opera- tion. Switch into the menu Menu ...
Page 39
Properties of PU-R can be changed in the menu: Menu Settings After properties of the keypad have been changed, its settings are applied au- tomatically (no need to program the keypad). Settings of PU-R’s users and text descriptors of global partitions are changed for every keypad separately.
5 Configuration of Strelec Wireless Keypad PU-R 5.5 Import Strelec’s properties Import of properties is performed in order to upgrade the Strelec’s configuration stored in the keypad. Import of properties is necessary if: 1. Several keypads are located in Strelec and the Strelec configuration has been changed by one of them, 2.
Page 41
5 Configuration of Strelec Wireless Keypad PU-R + WEx 0 - WEx 0 + Devices Properties Show Hide Action Press Press Choose the option “Read properties” in the opened list of actions. The import of properties is accompanied by the corresponding indication and if the information has copied successfully, the window, reporting this, will occur at the screen.
1. Export of the system’s configuration from a PC to the keypad ("export of Strelec to PU-R"). 2. Import the Strelec’s configuration from PU-R to a PC ("importing the sys- tem from PU-R"). 3. Clear off the configuration of the system in the keypad and recover manu- settings of the keypad ("keypad’s formatting").
User manual. In order to export the system, in the utility file WireEx select the command "Main window -> File ->Export of Strelec to PU-R". In order to import, select "Main window -> File ->Import of Strelec from PU-R".
Page 44
5 Configuration of Strelec Wireless Keypad PU-R Select a device in the opened list, which com- munication quality is necessary to evaluate. – Devices The assessment grade is displayed in the bot- 0.1 Ikar-R tom part of the screen. 31 dB Grade-5...
Reading value below the moving cursor is also displayed at the left bottom corner in RSSI units. When the wireless interface is turned on, PU-R defines a level of the signal by us- ing its receiver, when the interface RS-232 is turned on, a signal’s level is read by PU-R from the wireless expander.
Should daily arming/disarming be controlled by PU-R, install the keypad in close proximity to an entrance door Install PU-R at the distance of not far than 1.5 m from the wireless expander. If possible, install the keypad far from (the minimum distance is 0.5 m) metal objects, metal doors, metallized window openings, etc., as well as current-...
Page 47
The detector of wall detachment is designed to monitor unau- thorized detachment of PU-R from the wall. When the detector of wall detachment is triggered, the wireless expander functioning as a network coordinator (RR 0) re- ceives a message "Tamper".
Page 48
►PU-R mounting without using the detector of wall detachment 1. Turn the screws 6 and 7 off and remove the top part of PU-R from its base. 2. To mount PU-R to the wall, prepare...
Page 49
3. Hang the base to the inserted screws 1 and 2 and insert the screws 3, 4 and 5 to the base. 4. Install the top part of PU-R to the base fixed on the wall. 5. Secure the top part pf PU-R to the base by inserting the screws 6 and 7.
Page 50
┴ ATTENTION! When PU-R is power supplied from a network adapter or external power source, a battery is recommended to be connected as secondary power source. Should PU-R be stationary connected to the wireless expander RROP through the...
Page 51
6 Assembling the keypad Wireless keypad PU-R Upon finishing assembling, close the cover of the battery department and secure it with a screw. Use a screwdriver to open the cover of the battery department, when necessary.
"Status" (see the paragraph 7.3, page 54). The values mentioned are referred only to the delay of displaying information about Strelec’s status at the keypad PU-R! Triggering delays of relay outputs, outputs of audible and light indication, etc. have significantly less values in the wireless expander.
7 strelec’s control Wireless keypad PU-R The wireless expander’s event protocol remembers all the events occurred. Proto- col reading is performed in the menu "Event protocol" (see the paragraph 7.4, page 58). Strelec’ control operations are described in the paragraphs 7.5 – 7.12.
To review Strelec’s state, switch into the menu Menu System state ‹ State › Main window of PU-R screen button In the list of wireless expanders, no sym- bols against an expander, being in operating mode, should be displayed.
Page 55
Faults and tampers in page 61) or reset faults (the paragraph the partition 7.7, page 61). Similar to the software "Strelec", PU-R doesn’t indicate current status of local partitions of remote detectors. Information about the partition’s restored status is indicated in 32 sec.
Page 56
7 strelec’s control Wireless keypad PU-R Being in the window of reviewing the wireless expander’s local partitions status and selecting any local partition, a user is capable of supervising the partition. In order to supervise, the user is just required to enter an engineer or a user’s code (if a local partition is included in the list of partitions assessable for this user’s code.
Page 57
7 strelec’s control Wireless keypad PU-R When a device is in the normal state, the label “norm” will be displayed in all the lines. Other possible labels are the following: Line Label Fault correctness Restore the normal status of the detector BROKEN (close window and doors;...
To review the event protocol, select a menu’s option: Menu Events protocol Show protocol ‹ › or, while being in the main window of PU-R, press the button ‹ › Main window of PU-R The events protocol is read by PU-R from the memory of the expander, starting from the new- ...
Page 59
7 strelec’s control Wireless keypad PU-R Every record in the event protocol is accompanied by the time of its occurrence (according to the clock of the wireless expander). ‹ Details › To obtain detailed information about an event, press the button...
7 strelec’s control Wireless keypad PU-R 7.5 Arming Before arming the list of global partitions, make sure, their current status are normal ac- cording to corresponding pictographs. Num- bers should be glowing continuously. The pictographs , should not be displayed in the upper part of the window. If they are glowing, study Strelec’s sta- tus according to the paragraphs 7.1-7.3.
7 strelec’s control Wireless keypad PU-R When arming with bypass, a window displaying the number of the detector by- passes and the pictograph at the top part of the screen will occur. If a partition has several detectors, only tampered detectors should be bypasses.
7 strelec’s control Wireless keypad PU-R ‹ › NN CCCC where: NN – user’s number, from 00 to 30. A user with the number 00 is an engineer. CCCC – user’s code, from 0000 to 9999; If resetting has been completed successfully, a window reporting about resetting of faults and fire alarms will occur at the screen.
A delay depends on the type of PU-R’s power supply and the current interface (see the paragraph 7.1). Manual bypass can be turned on only if the option of manual bypass has been included to the options of the wire- less expander.
To turn an address bypass on, switch into the menu: Menu Control Code Manual bypass ‹ › Main window of PU-R Code Manual bypass Select a detector in the window of the network topology that is required to be bypassed and –...
Menu Control Code Output modules groups ‹ › Main window of PU-R Code Output modules groups The groups included are marked by dots at the screen. To exclude a group, mark its number by ‹...
2 digits, each lies within the range 00-99. One of the digits is acces- sible to be changed by a user. Another is selected randomly by PU-R. Frequency range – selection of a frequency range (434 МHz or 868 МHz Channel’s number –...
An access code is stored in the memory of the wireless expander. The code is produced by PU-R upon connection with a wireless expand- er. To display the code, enter 4 digits from the keypad. To change a cur- rent code of the expander into a new one, press the screen button ‹...
Page 68
Global partitions are necessary for arming partitions of remote wireless expanders. Note: PU-R enables performance of those control operations that are ac- companied by entering a user’s code only for global partitions. Comment – allocating text descriptors to local partitions of an expander.
Page 69
Wireless keypad PU-R disarming Event of WEx – influence of the wireless expander’s own events (case’s tampering and power supply’s fault) to the relay. Influence of partitions – connection of events occurred in the partitions of the wireless expander with the relay.
Wireless keypad PU-R The number of wireless expanders = 3. Address in the SL Wireless Partitions of the "Akkord-512" expander wireless expander 9-16 9-16 9-16 Autonomous mode – the mode, in which WEx is becoming a key element of the SL "Akkord-512", and its address in the SL is 0.
Wireless keypad PU-R The address lies within the range from 1 to 8. This address is used for WExF to acknowledge control signals of SL integrity. The address is select- ed only from the programmed addresses (one of the system’s partitions must have this address in the SL).
Page 72
Wireless keypad PU-R Transmission period – transmission period of control wireless signals by a detector. The transmission period can be increased to extend a battery’s service life, or decreased to raise a speed of detectors’ respond. Communication control – a period, after which expiration, a signal about a fault in communication with a detector, lacking control wireless sig- nals, will be generated.
Wireless keypad PU-R 8.6 Properties of control devices The properties required to be configured, while adding a device, are in bold. ►Common properties The common properties of the devices RBU, PUL-R correspond to the common properties of detectors. ►Properties of PUL-R ...
Page 74
Wireless keypad PU-R Stop relay Number of WEx and relay number Forced disarming Partitions list Fire and faults reset Partitions list Fire alarm Partition number PUL-R functioning as a slave device of the network coordinator (WEx) can also perform the following actions:...
Wireless keypad PU-R 8.7 Properties of output modules groups The properties required to be configured while adding a device, are written in bold. ►Common The common properties of the devices OM-R version 1 and 2, Sirena-R: Partition number – a local partition’s number assignment. The events such as faults or tampers are transferred from an output module in this local partition.
Wireless keypad PU-R ►Properties of OM-R, versions 1 and 2 Control of input Flt – if control is on, a fault signal (“Fault”) is trans- ferred to the wireless expander, when load resistance connected to the input “Flt”, reaches some high values. Resistance thresholds are the fol-...
Wireless keypad PU-R ►Properties of the auto dialer UOO-AV (version 1) Telephone numbers 1-4 – telephone numbers of the Monitoring Sta- tion’s telephone lines. The telephone numbers can include numbers from 0 to 9, as well as symbols: ‘t’ and ‘p’.
Need help?
Do you have a question about the PU-R and is the answer not in the manual?