Foreword Dear customer, By purchasing the control unit Quantron E2 for the mineral fertiliser spreader AXIS, you have shown confidence in our product. Thank you! We want to justify your trust. You have purchased a powerful and reliable control unit. Our customer service is always at your disposal, should any problems arise.
User instructions About this operating manual This operating manual is a constituent part of the control unit Quantron E2. The manual contains important instructions for safe, proper and economic use and maintenance of the control unit. Adherence to the manual helps to avoid dangers, reduce repair costs and downtime and to increase the machine's relia- bility and service life.
Page 8
User instructions Warning severity level The degree of danger is indicated by the signal word. The levels are classified as follows: n DANGER Type and source of danger This note warns of a danger posing an immediate threat to the health and life of persons.
User instructions 1.2.2 Instructions and procedures Action steps that the operator must carry out are shown as a numbered list. 1. Instruction for action step 1 2. Instruction for action step 2 Instructions involving only one step are not numbered. The same applies to ac- tion steps that do not have to be carried out in a specific sequence.
Layout and function Layout and function Overview of the supported AXIS versions Function/options AXIS W Weighing spreader AXIS 20.1 W AXIS 30.1 W AXIS 40.1 W AXIS 50.1 W Electrical adjustment of drop point AXIS 50.1 W...
Layout and function Layout of the control unit - overview Figure 2.1: Control unit Quantron E2 Designation Function Control panel Consisting of foil buttons used to operate the device and the display for operating screens. V24 data port Serial interface (RS232) with LH 5000 and ASD protocol, designed for connecting an Y-RS232 cable for the connection to a remote terminal.
Layout and function Control elements The Quantron E2 is operated via 17 foil buttons (13 strictly defined and 4 freely assignable foil buttons). Figure 2.2: Control panel on the front panel of the unit NOTICE The operating manual describes the functions of the control unit Quantron E2 as of software version 1.20.00.
Page 14
Layout and function Designation Function Preselected sec- Preselect sections for changing the application rates tion setting (Left or Right or Left + Right). Menu Switch between operating screen and main menu. For aborting information input and/or returning to the previous menu at the same time. Navigation field 4 arrow keys and one enter key for navigating through the menus and input fields.
Layout and function Display The display shows the current status information and the selection and input op- tions for the control unit. The most important information on the operation of the mineral fertiliser spreader is displayed in the operating screen. Description of the operating screen NOTICE The exact representation of the operating screen depends on the actual settings...
Page 16
Layout and function The icons and displays in the example have the following meaning: No. Icon/Display Meaning (in the example) Metering slide Current opening position of the left metering slide. scale opening left Operating mode Shows the current operating mode. Auto km/h uses the radar signal or wheel signal for determining the speed.
Attachment and installation Attachment and installation Requirements for the tractor Before installing the control unit, check to make sure your tractor meets the fol- lowing requirements: A minimum voltage of 11 V is essential at all times, even if multiple loads are connected simultaneously (e.
Attachment and installation 3.2.2 7-pin plug connector The control unit receives the pulses for the current forward speed via the 7-pin plug connector 9684-1/ISO 11786). For this purpose, the 7-pin to 8-pin cable (ac- cessory) is connected to the forward speed sensor at the plug connector. [1] PIN 1: actual forward speed (radar) [2] PIN 2: theoretical forward speed (e.
Attachment and installation Connecting the control unit NOTICE After the control unit Quantron E2 has been switched on, the machine number will be shown in the display for a short period of time! n CAUTION Note machine number! The control unit Quantron E2 has been calibrated at the fac- tory for the mineral fertiliser spreader with which it was sup- plied.
Page 22
Attachment and installation Standard schematic connection diagram: km/h Figure 3.3: Schematic connection diagram Quantron E2 [1] Serial interface RS232, 8-pin plug connector [2] 39-pin machine plug [3] Optional: Drop point adjustment (only for AXIS 50.1 W) [4] Optional: Telimat sensor top/bottom...
Page 23
Attachment and installation Schematic connection diagram for wheel sensor: km/h Figure 3.4: Schematic connection diagram Quantron E2 [1] Serial interface RS232, 8-pin plug connector [2] 39-pin machine plug [3] Optional: Drop point adjustment (only for AXIS 50.1 W) [4] Optional: Telimat sensor top/bottom...
Page 24
[10] 3-pin plug connector conforming to DIN 9680/ISO 12369 [11] Optional: Y-cable (V24 RS232 interface for storage medium) [12] Forward speed sensor [13] Optional: Quantron E2 power supply via ignition lock [14] 7-pin plug connector conforming to DIN 9684 [15] Optional: GPS cable and receiver...
CAUTION Check the position of the metering slide! Operation of the actuators by the Quantron E2 can cause damage to the metering slides if the stop levers are incorrectly positioned. Always clamp the stop levers at the maximum scale posi- tion.
15). A minimum voltage of 11 V is applied. NOTICE The operating manual describes the functions of the control unit Quantron E2 as of software version 1.20.00. n CAUTION Risk of injury due to ejected fertiliser! Only for mineral fertiliser spreaders with electronic control unit In the case of a fault, it is possible that the metering slide unex- pectedly opens during road transport to the spreading location.
Page 28
Operation of the Quantron E2 Switching the unit on: Press the ON/OFF switch. After a few seconds, the start interface appears on the control unit. Then the boot menu is displayed for a few seconds. Then the operating screen appears.
Operation of the Quantron E2 Weighing-trip counter In this menu, you can have the values of the spreading work carried out displayed and you can perform functions for the weighing operation. Press the kg key on the control unit. The weighing-trip counter menu opens.
Operation of the Quantron E2 4.2.1 Trip counter You can find values for the completed spreading work (quantity, area, distance) in this menu. Figure 4.3: Trip counter menu [1] Display of spread quantity since the last reset [2] Display of spread area since the last reset...
Operation of the Quantron E2 4.2.2 Determining the applied fertiliser quantity In the Compare kg counter menu, you can display and compare the fertiliser quantity applied according to the scale after the spreading. The menu will display the applied fertiliser quantity in kg.
Operation of the Quantron E2 4.2.3 Remaining fertiliser quantity In the kg left menu, you can call up or enter the remaining fertiliser quantity in the hopper. The menu shows the possible area (ha) and distance (m) that can be spread with the remaining fertiliser quantity.
Page 33
Operation of the Quantron E2 Entering the remaining fertiliser quantity when refilling: 1. Switch from the weighing-trip counter menu to the kg left menu. The remaining fertiliser quantity from the last spreading process appears in the display. 2. Fill the hopper.
Operation of the Quantron E2 4.2.4 Weigh quantity In this menu, you can weigh the fertiliser quantity contained in the hopper and set the parameters for controlling the flow factor. Figure 4.6: Weigh quantity menu [1] Display of spreader's forward speed...
Page 35
PTO is switched off, the mineral fertiliser spreader is in a horizontal position and off the ground, the tractor is at a standstill, the Quantron E2 is switched on. Weighing the fertiliser quantity in the hopper: 1. Fill the hopper.
Page 36
Operation of the Quantron E2 Working with the weighed fertiliser quantity, refilling the hopper: 1. Tare the scale. See chapter 4.2.5: Machine tare, page 2. Select the fertiliser type to be used. See chapter 4.5.7: Fertiliser chart, page 3. Fill the hopper.
Operation of the Quantron E2 4.2.5 Machine tare In this menu, set the weighing value for the empty weighing spreader to 0 kg. When taring the scale, ensure that: the hopper is empty, the fertiliser spreader is at a standstill,...
Operation of the Quantron E2 4.2.6 Telimat Attachment options for the AXIS W mineral fertiliser spreader NOTICE The Telimat option is preset for the control unit at the factory! Telimat with hydraulic remote control The Telimat is hydraulically moved to its working or idle position. Pressing the T key will activate or deactivate the Telimat.
Page 39
Operation of the Quantron E2 Telimat with electrical remote control By pressing the T key, the electrical Telimat will automatically move to the border spreading position. During the adjustment, an "?" symbol will appear in the dis- play of the control unit, which will disappear again once the working position has been reached.
Operation of the Quantron E2 Main menu Press the menu key in the operating screen. The main menu opens on the display. Figure 4.11: Main menu Quantron E2 The main menu shows the following submenus. Submenu Meaning Description Fertiliser settings...
Operation of the Quantron E2 Fertiliser settings in Easy mode The mode settings are described in section 4.9.3: Mode, page You can adjust the settings for the fertiliser and spreader operation in this menu. Switch from the main menu to the Fertiliser settings menu.
Operation of the Quantron E2 Fertiliser settings in Expert mode The mode settings are described in section 4.9.3: Mode, page In this menu, you can enter the settings for the fertiliser and spreader operation. In comparison to the Easy mode, this menu contains further setting pages as well as the fertiliser chart.
Page 43
Operation of the Quantron E2 The main menu shows the following submenus. Submenu Meaning/Possible values Description Name of fertiliser Fertiliser selected from the fertiliser chart. Page 49 Application rate Input of target value for the application Page 39 rate in kg/ha.
Page 44
Operation of the Quantron E2 Submenu Meaning/Possible values Description Composition Percentage content of chemical composi- tion. Fertiliser chart Management of fertiliser charts. Page 49 How to select a submenu: 1. Highlight the submenu with the black bar in the display. The highlight bar can be moved up and down with the arrow keys.
Operation of the Quantron E2 4.5.1 Application rate In this menu, you can enter the desired target value for the application rate. Figure 4.14: Appl. rate menu Entering the application rate: 1. Switch from the Fertiliser settings menu to the Application rate menu.
Operation of the Quantron E2 4.5.2 Working width You can set the working width (in metres) in this menu. Figure 4.15: Working width menu Entering the working width: 1. Switch from the Fertiliser settings menu to the Working width menu.
Operation of the Quantron E2 4.5.3 Flow factor The flow factor is within the range of 0.4 to 1.9. The following applies under the same basic conditions (km/h/, working width, kg/ha): If the flow factor is increased, the dosing quantity is reduced.
Page 48
Operation of the Quantron E2 NOTICE If your fertiliser is not listed in the fertiliser chart, enter the flow factor 1.00. In the AUTO km/h and MAN km/h operating modes, we strongly recommend that you perform a calibration to precisely determine the flow factor for this fer- tiliser.
Operation of the Quantron E2 4.5.4 Drop point If the Quantron E2 is connected to a AXIS 50.1 W mineral fertiliser spreader, the drop point is electrically confirmed and set. NOTICE Entering the drop point for AXIS 20.1 W, AXIS 30.1 W or AXIS 40.1 W is mere- ly informative and does not affect the settings of the fertiliser spreader.
Operation of the Quantron E2 4.5.5 Telimat quantity In this menu, you can determine the Telimat quantity reduction (in percent) that will be used during the activation of the border spread function by means of the Telimat sensor or the T key.
Operation of the Quantron E2 4.5.6 Calibration In this menu, you can determine the flow factor based on a calibration and save it in the control unit. Carry out a calibration: before spreading for the first time. if the fertiliser quality has changed significantly (moisture, high dust content, cracked grain).
Page 52
Operation of the Quantron E2 Figure 4.20: Prepare calibration operating screen [1] Symbol above function key F4 to select right spreading side [2] Symbol above function key F1 to select left spreading side [3] Display of section Selecting the section: 1.
Page 53
Operation of the Quantron E2 Figure 4.21: Run calibration operating screen [1] Display of elapsed time since starting the calibration [2] Active section (in this case: left side) NOTICE The calibration time is not relevant to the accuracy of the results. However, at least 20 kg must be spread.
Page 54
Operation of the Quantron E2 Recalculating the flow factor 1. Weigh the discharged fertiliser quantity. 2. Enter the weight of the discharged fertiliser quantity in the input field of the Input collected weight menu. See also chapter 4.11.2: Input of values using the cursor keys, page 3.
Operation of the Quantron E2 4.5.7 Fertiliser chart In the Expert mode, you can use this menu to create and manage, see chapter 4.9.3: Mode, page 81, the fertiliser charts. NOTICE The selection of a fertiliser chart has an effect on the fertiliser settings, the con- trol unit and the mineral fertiliser spreader.
Page 56
Operation of the Quantron E2 3. Press the enter key. The selection menu is displayed. Figure 4.25: Selection menu 4. Highlight the function open element. 5. Press the enter key. The display shows the Fertiliser settings menu and the selected element is loaded as active fertiliser chart in the fertiliser settings.
Page 57
Operation of the Quantron E2 Copying an existing fertiliser chart 1. Select the desired fertiliser chart in the Fertiliser chart operating screen and confirm the selection with the enter key. The selection menu is displayed. Figure 4.26: Selection menu 2. Select the function Copy element.
Operation of the Quantron E2 Machine settings You can adjust the settings for the tractor and mineral fertiliser spreader in this menu. Switch from the main menu to the Hopper configuration menu. Figure 4.28: Hopper configuration NOTICE The menu item kg counter cradle will only be displayed in the operating modes AUTO km/h + Stat.
If possible, only fill the mineral fertiliser spreader until it is half-full. Calling up the speed settings: In the control unit Quantron E2 up to 4 different profiles for type and number of pulses can be saved. You can assign names to these profiles (e. g. tractor name).
Page 60
Operation of the Quantron E2 Recalibrating the speed signal: You can either overwrite an existing profile or create a profile in an empty memory location. 1. Highlight the desired memory location using the function key below it in the Tractor (km/h) menu.
Page 61
Operation of the Quantron E2 The number of pulses of the speed signal must still be specified below. If you know the exact number of pulses, you can enter it directly: 7. Highlight the Imp/100m submenu and press the enter key.
Operation of the Quantron E2 4.6.2 AUTO/MAN mode The default operating mode is the AUTO mode. The control unit automatically controls the actuators based on the speed signal. Only work in manual mode, if: there is no speed signal (radar or wheel sensor not available or defective), slug pellets or seeds (fine seeds) are to be applied.
Page 63
Procedure when spreading with Auto km/h + Auto kg: 1. Each time you switch on the Quantron E2, use the kg key to switch to the weigh quantity menu and weigh the fertiliser quantity using refill or new fer- tiliser.
Page 64
Operation of the Quantron E2 5. Highlight the action carried out in the display: Refill: Continue spreading with the same fertiliser. The flow factor setting is retained. The remaining fertiliser quantity is increased by the refilling quantity. New fertiliser: Flow factor is set to 1.0 and a new flow factor regulation will follow.
Page 65
Selecting AUTO km/h + Stat. kg: 1. Switch on the control unit Quantron E2. 2. Fill the hopper with fertiliser. 3. Switch from the machine settings menu to the AUTO/MAN mode menu.
Page 66
Operation of the Quantron E2 b) Procedure when spreading with Auto km/h + Stat. kg: 1. Each time you switch on the Quantron E2, use the kg key to switch to the Weigh quantity menu and weigh the fertiliser quantity using Refill or New fertiliser.
Page 67
Automatic mode (Auto km/h) a) Selecting Auto km/h: 1. Switch on the control unit Quantron E2. 2. Switch from the Hopper configuration menu to the AUTO/MAN mode menu. 3. Highlight the AUTO km/h selection field.
Page 68
Operation of the Quantron E2 b) Procedure when spreading with Auto km/h: 1. Adjust the fertiliser settings: Application rate (kg/ha) Working width (m) 2. Pour the fertiliser in. 3. Carry out a calibration to determine the flow factor Refer to the fertiliser chart for the flow factor and enter it manually.
Page 69
Operation of the Quantron E2 Manual operation (MAN km/h) 1. Switch from the Hopper configuration menu to the AUTO/MAN mode menu. 2. Highlight the MAN km/h selection field. The forward speed menu is displayed. 3. Enter the value for the forward speed during spreading. Confirm the input by pressing the enter key.
Page 70
Operation of the Quantron E2 The metering slide opening can be changed manually during spreader operation in the MAN scale mode. Requirements: The metering slides are open (activation with the start/stop key). In the MAN scale operating screen, the symbols for the sections are filled in red.
Operation of the Quantron E2 4.6.3 +/- appl. rate In this menu, you can specify a quantity change on a percentage basis. The basis (100 %) is the pre-set value of the metering slide opening. NOTICE During operation, you can use the function keys F2/F3 to change the spreading quantity by the factor of the +/- appl.
Operation of the Quantron E2 4.6.4 kg counter cradle Here, you can activate the display of the Compare kg counter function in the Weighing-trip counter menu. NOTICE The menu item kg counter cradle will only be displayed in the operating modes AUTO km/h + Stat.
It is moreover recommended to open both opening slides completely via the fast emptying and to switch off the Quantron E2 before storing the mineral fertiliser spreader, in order to prevent the formation of humidity in the fertiliser tank.
Page 74
Operation of the Quantron E2 3. Press the start/stop key. Fast emptying is started. Figure 4.37: Fast emptying menu [1] Fast emptying symbol (in this case: left side selected, fast emptying started) 4. To stop fast emptying, press the start/stop key again.
Operation of the Quantron E2 Field data In this menu, you can create and save up to 200 operating data files. Switch from the main menu to the field data menu. Figure 4.38: Field data menu [1] Display of page number...
Operation of the Quantron E2 4.8.2 Starting recording 1. Switch from the Field data menu to the current field data file. Figure 4.39: Display of current field data [1] Display of the page number [2] Name field of field data...
Page 77
Operation of the Quantron E2 2. Press the function key F1 below the start symbol. The recording starts. In the Field data menu of the current field data, the recording symbol is displayed. The operating screen displays the recording symbol .
3. Press the ESC key to return to the previous menu press the menu key to return to the operating screen. 4.8.4 Importing and exporting field data The control unit Quantron E2 allows for importing and/or exporting the recorded field data. Importing field data (PC to Quantron E2) Requirements: Use the USB stick supplied.
Page 79
The field data import can be interrupted at any time by pressing the ESC key! The consequences of importing operating data are as follows All field data currently stored in the Quantron E2 are overwritten. If you have defined the application rate on the PC, the application rate is au- tomatically transferred and immediately activated in the fertiliser settings menu when starting the field data.
Page 80
Operation of the Quantron E2 Exporting field data (Quantron E2 to PC) Requirements: Use the USB stick supplied. Do not alter the directory structure on the USB stick. The data on the USB stick are available in the directory path "\\USB- BOX\QuantronE\Schlagdateien\Export".
Operation of the Quantron E2 4.8.5 Deleting field data The control unit Quantron E2 allows for deleting the recorded field data. NOTICE Only the content of the field data will be deleted, the field data name will still be displayed in the name field! Deleting field data 1.
Page 82
Operation of the Quantron E2 2. Press the function key F2 below the Delete all symbol. A message appears indicating that all data will be deleted. Figure 4.46: Message prior to deletion of the files 3. Press the start/stop key.
Operation of the Quantron E2 System/Test Use this menu for the system and test settings of the control unit. Switch from the main menu to the System/test menu. Figure 4.47: System / Test menu Submenu Meaning Description Brightness Setting of the displayand of the Settings can be adjusted us- key lighting.
Page 84
Operation of the Quantron E2 Submenu Meaning Description Time Setting the current time. Selection and modification of the settings by means of the arrow keys Confirma- tion with the enter key Data transmis- Menu for data exchange and se- Page 84...
Operation of the Quantron E2 4.9.1 Setting the language The control unit Quantron E2 can be set to 22 different languages. The language package for your country is preloaded at the factory. 1. Switch from the system/test menu to the languages submenu.
Operation of the Quantron E2 4.9.2 Display config. The display fields in the operating screen of the control unit can be configured as desired. You can assign the three display fields with the following values if de- sired: Forward speed...
Operation of the Quantron E2 4.9.3 Mode The control unit Quantron E2 can be set to 2 different modes. The easy or expert mode. In the easy mode, only the parameters of the fertiliser settings required for spreading can be accessed; it is not possible to create or manage the fertiliser charts.
Operation of the Quantron E2 4.9.4 Test/Diagnosis In the Test/diagnosis menu, you can monitor and check the functions of certain sensors/actuators. NOTICE This menu serves for information purposes only. The list of the sensors depends on the equipment of the machine.
Page 89
Operation of the Quantron E2 Test/Diagnosis; example: slide 1. Switch from the System/Test menu to the Test/Diagnosis submenu. 2. Highlight the desired function and press the enter key. The status of the sensors/actuators is displayed. Figure 4.53: Test/Diagnosis; example: slide...
Operation of the Quantron E2 4.9.5 Data transmission Data transmission is carried out using various data protocols. Figure 4.54: Data transmission menu Submenu Meaning Description Automatic field documentation; transmission of field data to a PDA and/or Pocket PC via Bluetooth LH5000 Serial communication e.
Operation of the Quantron E2 4.9.6 Total data counter In this menu, all of the spreader's counter readings are displayed. spread quantity in kg spread area in ha spread time in h distance travelled in km NOTICE This menu serves for information purposes only.
Operation of the Quantron E2 4.9.7 Service NOTICE An input code is required for the settings in the service menu. These settings can only be modified by authorised service personnel. As a general rule, we recommend that all settings in this menu are carried out by authorised service personnel.
Operation of the Quantron E2 4.11 Special functions 4.11.1 Text input You can enter freely editable text in some menus. Figure 4.58: Text input menu [1] Input field [2] Character field, display of available characters (language-dependent) [3] Function keys for navigation in the input field Entering text: 1.
Page 94
Operation of the Quantron E2 Overwriting characters: A single character can be overwritten by another character. 1. Move the cursor to the position of the character to be deleted in the input field by using the function keys. 2. Replace the character by selecting the desired character in the character field.
Operation of the Quantron E2 4.11.2 Input of values using the cursor keys In some menus, numerical values can be entered. Figure 4.59: Input of numerical value (example application rate) [1] Input field You are already in the menu in which you can enter numerical values.
Alarm messages and possible causes Alarm messages and possible causes Various alarm messages can be displayed on the Quantron E2 control unit dis- play. Meaning of alarm messages Message in display Meaning Possible cause Fault in metering system. The actuator for the metering system can- not reach the set value it is to be moved to.
Page 98
Alarm messages and possible causes Message in display Meaning Possible cause Min. setting = 12.00 Reference to the value range of the work- Max. setting = 50.00 ing width. Entered value is not permitted. Min. setting = 0.40 Reference to the value range of the flow Max.
Page 99
Alarm messages and possible causes Message in display Meaning Possible cause Error in Telimat setting. Actuator overloaded. Defective Telimat setting. Defective Telimat actuator. Flow factor has changed dra- The flow factor must be within the range of matically, please check! 0.50 - 1.80.
Alarm messages and possible causes Clearing a fault/alarm 5.2.1 Acknowledging an alarm message An alarm message is highlighted in the display and displayed with a warning sym- bol. Figure 5.1: Alarm message (e.g. metering device) Acknowledging an alarm message: 1. Correct the cause of the alarm message. Observe the operating manual of the mineral fertiliser spreader and section 5.1: Meaning of alarm messages, page 2.
1. Proceed as described in chapter 5.2.1: Acknowledging an alarm message, page 2. Switch the control unit Quantron E2 off (ON/OFF) and then restart it. 3. Switch to the weigh quantity menu using the kg key. 4. Select the function new fertiliser.
Special equipment/options Special equipment/options No. Illustration Designation Empty message sensor for AXIS Forward speed sensor for Quantron A Y cable RS232 for data exchange (e. g. GPS, N sensor, etc.) System tractor cable set for Quantron AXIS 12 m...
Page 104
Special equipment/options No. Illustration Designation GPS cable and receiver Telimat sensor AXIS Suction cup bracket for Quantron E2...
Guarantee and warranty Guarantee and warranty KUHN S.A. 4, Impasse des Fabriques, 67706 SAVERNE Cedex FRANCE (hereinafter called "the Company") warrants, in accordance with the provisions below, to each retail purchaser of a new KUHN equipment from an authorized KUHN dealer, that such equipment is, at the time of delivery to such purchaser, free from defects in material and workmanship, and that such equipment is covered under this Limited Warranty providing the machine is used and serviced in accordance with the recommendations in the Operator's manual.
Page 106
Guarantee and warranty ■ The Limited Warranty is dependent on the strict observance of the following conditions: - The machine has been put in service by the dealer according to our instructions. - The machine has been registered on line via extranet - www.kuhn.com or the warranty/product registration form has been completed and returned to the address indicated on the form as soon as the machine had been delivered to the retail purchaser.
EC Declaration of Conformity EC Declaration of Conformity EC Declaration of conformity (European directive 2006/42/CE) The manufacturer: KUHN S.A., 4 impasse des fabriques B.P. 50060 F - 67706 SAVERNE CEDEX declares that the product described hereafter: Type: ’’Machine name’’ Serial no.: ’’Machine serial number’’ - conforms to the requirements of the European directive 2006/42/CE - conforms to the requirements of following European harmonized standards: EN 1553 - NF U 02-007 - EN 703 - EN 708 - EN 745+A1 - EN 907...
Page 108
www.kuhn.com KUHN S.A. B.P. 50060 F - 67706 SAVERNE CEDEX (FRANCE) Tél. : + 33 (0) 3 88 01 81 00 - Fax : + 33 (0) 3 88 01 81 01 Société Anonyme au Capital de 19 488 000 Euros KUHN-AUDUREAU S.A.
Need help?
Do you have a question about the Quantron E2 and is the answer not in the manual?
Questions and answers