Download Print this page

Martin P3-100 Troubleshooting Manual

System processor
Hide thumbs Also See for P3-100:

Advertisement

Quick Links

Martin P3-100/P3-200 System Processor
Troubleshooting Guide – for Martin Service Technicians
Symptoms
Unit does not boot
No LEDs lit on front panel
Unit does not boot
Only active LED is lit and flashes
Error Code – bottom 4 LEDs, 3 flashes
"Firmware failed to boot"
Error Code – bottom 4 LEDs, 4 flashes
"Power failed during boot"
Error Code – all LEDs, 1 Flash
"unable to read build information"
Bios, Martin Logo, Beeps, but black monitor
Unable to communicate with Front Panel error
No USB power initially to mouse
Cursor temporarily frozen on error message
Possible Cause
1) Fuse blown
2) PSU has blown
1) CF Card Corruption
2) Processor board fault
1) CF Card Corruption
2) Processor board fault
1) CF card unseated
3) Processor board fault
1) Likely to be a front panel problem
1) Monitor is incompatible/connector
modified
2) Internal Cable has come lose
3) Processor board fault?
1) Likely to be a Processor Board Fault
Action
1) Replace Fuse
2) RMA - Replace PSU
1) Run CF Card recovery Tool
2) RMA – Replace Processor Board
1) Run CF Card recovery Tool
2) RMA – Replace Processor Board
1) Remove, then reinsert CF card
2) Run CF Card recovery Tool
3) RMA – Replace Processor board
1) RMA – Replace Front Panel
1) Check connections between P3 System
Controller and Monitor
Test with different monitor
2) Check internal VGA cables
3) RMA for investigation
1) RMA – Replace Processor Board

Advertisement

loading

Summary of Contents for Martin P3-100

  • Page 1 Martin P3-100/P3-200 System Processor Troubleshooting Guide – for Martin Service Technicians Symptoms Possible Cause Action  Unit does not boot 1) Fuse blown 1) Replace Fuse  2) PSU has blown 2) RMA - Replace PSU No LEDs lit on front panel ...
  • Page 2 2) RMA for investigation Unit shuts down within a couple of minutes Chip issue  Analogue video capture fails (P3-100) 1) Possible setup issue 1) Try different source and cable 2) Possible capture card fault 2) RMA - Replace capture card ...

This manual is also suitable for:

P3-200