Symptoms

Unit does not boot

No LEDs lit on front panel

Unit does not boot

Only active LED is lit and flashes

Error Code – bottom 4 LEDs, 3 flashes
"Firmware failed to boot"
Error Code – bottom 4 LEDs, 4 flashes
"Power failed during boot"
Error Code – all LEDs, 1 Flash
"unable to read build information"

Bios, Martin Logo, Beeps, but black monitor

Unable to communicate with Front Panel error

No USB power initially to mouse

Cursor temporarily frozen on error message
Possible Cause
1) Fuse blown
2) PSU has blown
1) CF Card Corruption
2) Processor board fault
1) CF Card Corruption
2) Processor board fault
1) CF card unseated
3) Processor board fault
1) Likely to be a front panel problem
1) Monitor is incompatible/connector
modified
2) Internal Cable has come lose
3) Processor board fault?
1) Likely to be a Processor Board Fault
Action
1) Replace Fuse
2) RMA - Replace PSU
1) Run CF Card recovery Tool
2) RMA – Replace Processor Board
1) Run CF Card recovery Tool
2) RMA – Replace Processor Board
1) Remove, then reinsert CF card
2) Run CF Card recovery Tool
3) RMA – Replace Processor board
1) RMA – Replace Front Panel
1) Check connections between P3 System
Controller and Monitor
Test with different monitor
2) Check internal VGA cables
3) RMA for investigation
1) RMA – Replace Processor Board

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P3-100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Martin P3-100

  • Page 1 Martin P3-100/P3-200 System Processor Troubleshooting Guide – for Martin Service Technicians Symptoms Possible Cause Action  Unit does not boot 1) Fuse blown 1) Replace Fuse  2) PSU has blown 2) RMA - Replace PSU No LEDs lit on front panel ...
  • Page 2 2) RMA for investigation Unit shuts down within a couple of minutes Chip issue  Analogue video capture fails (P3-100) 1) Possible setup issue 1) Try different source and cable 2) Possible capture card fault 2) RMA - Replace capture card ...

This manual is also suitable for:

P3-200

Table of Contents