Measuring instrument for precise blood pressure and pulse rate
measurement on the upper arm
This device complies with the requirements of the standards referred to the Directive R&TTE
1999/5/EC. The Declaration of Conformity you find here: www.technaxx.de/ (in bar at the bottom
"Konformitätserklärung"). Before using the device the first time, read the user manual carefully.
This device has a rechargeable battery. It must be fully charged before first use.
NOTE: Charge the battery of the device every 2–3 month if it is not used!
Service phone No. for technical support: 01805 012643 (14 cent/minute from German fixed-line and
42 cent/minute from mobile networks). Free Email: support@technaxx.de
Features
 Enables very fast and reliable measurement of systolic and diastolic blood pressure as
well as pulse rate through the oscillometric method  Voice broadcast function  Bluetooth
connection (V4.0 & 3.0) with Smartphone  Operating through iOS or Android APP
 Unlimited number of users 1-key operation on device  Storage of the last 99
measurements (at the end of a measurement the device automatically stores each result
with date and time)  LED charging & Bluetooth indicator  Blood pressure result indicator
 Ø value function of the last 15 measurements  IP21 protection class (against solid
debris/material Ø 12.5mm & against vertically falling water drops)  Cuff and main unit are
integrated as one part  Built-in rechargeable lithium ion 800mAh battery 3.7V  For use at
home or in ambulances  Clinically proven accuracy and user friendly design
Important Hints and Warnings – Read carefully !
 Contact your doctor for further questions on the subject of blood pressure and its
measurement. In cases of irregular heartbeat, measurements made with this instrument
should only be evaluated after consultation with your doctor. Self-measurement means
control, not diagnosis or treatment, but only a healthcare professional is qualified to
interpret blood pressure measurements. Unusual values must always be discussed with
your doctor. Under no circumstances should you alter the dosages of any drugs prescribed
by your doctor. Familiarize yourself with the section titled "Important Information on Blood
Pressure and its Measurement". It contains important information on the dynamics of blood
pressure readings and will help you to obtain the best results.
Note: Arm circumference should be measured with a measuring tape in the middle of the
relaxed upper arm. Do not force cuff connection into the open wound.

Advertisement

loading

Summary of Contents for Technaxx B06T

  • Page 1 This device complies with the requirements of the standards referred to the Directive R&TTE 1999/5/EC. The Declaration of Conformity you find here: www.technaxx.de/ (in bar at the bottom “Konformitätserklärung”). Before using the device the first time, read the user manual carefully.
  • Page 2  This device can not be used together with HF-surgical equipment.  The pulse display is not suitable for checking the frequency of heart pacemakers, and the device shall not be serviced or maintained while in use with the patient. This device is NOT intended to replace regular medical checkups.
  • Page 3 1.2. Which values are normal? Diastolic / Systolic blood presure Optimal blood presure (target value) Norma / High blood pressure Mild / Moderate / Severe hypertension Blood pressure is very high if your diastolic pressure is above 90 mmHg and/or your systolic blood pressure is over 160 mmHg, while at rest.
  • Page 4 1.3. What can be done if regular high or low values are obtained? a) Consult your doctor. b) Increased blood pressure values (various forms of hypertension) are associated with considerable health risks over time. Arterial blood vessels in your body are endangered due to constriction caused by deposits in the vessel walls (Arteriosclerosis).
  • Page 5 3. Components of the Blood Pressure Monitor B06T Charge Port Battery / Bluetooth Indicator Blood Pressure Indicator Power on/off & Start/Stop Button Mem (= Memory button) / Vol – Mem (= Memory button) / Vol + Upper Arm Cuff 4. Using your Monitor for the First Time  System Settings After the battery is fully charged, some functions can be set before use this monitor: 4.1.
  • Page 6: Measurement Procedure

    5. Measurement Procedure Note: You should always be seated and calm before and during measurement. 5.1. Before measurement  Avoid eating and smoking as well as all forms of exertion directly before measurement. These factors influence the measurement result. Find time to relax by sitting in an armchair in a quiet atmosphere for about ten minutes before taking a measurement.
  • Page 7 c) Wrap the cuff around your upper left arm. The blue arrow (red mark) should be on the inside of your arm extending downward to your hand. Make certain the cuff lies approx. 1–2cm above the elbow. Important! The red mark on the edge of the cuff (Artery Mark) must lie over the artery which runs down the inner side of the arm.
  • Page 8 d) After the monitor has detected your blood pressure and pulse rate, the cuff automatically deflates. Your blood pressure will be voiced out or shown on the APP on smart phone if operated by APP. e) The monitor will automatically turn off after two minutes not in operation. See picture how to handle the device in the correct way: Sit vertically and relax your body Upper arm is not covered or pressed by...
  • Page 9 Second step: Turn on the APP. The Third step: Choose the Technaxx main display interface of the My blood pressure monitor: The APP Fitness will show up. will enter into the interface with different Technaxx devices. Choose the Technaxx BP monitors as shown in the picture.
  • Page 10 Forth step: Complete “My Profile” Setting the language: After setting and save it. the “My Profile”, it will come to this interface-picture. Press the button on the upper right. You can choose between 3 different Then you come to this language languages (English, German and setting interface-picture.
  • Page 11 Connect Bluetooth: Turn on your When you clicked on the button, you device and detect it by the Technaxx will come directly to this interface. APP (My Fitness). See the following 3 pictures. Click on the button “Bluetooth Device”. A moment later, the device will be connected...
  • Page 12 6.2. Start the measurement Once the device is connected via Bluetooth with your Smartphone, you can start the measurement by remote controlling on the APP. Slide the APP to the bottom and the Press the button “START” and start button “START” will show up as the testing is shown like in this shown in this picture.
  • Page 13 6.3. Check the measurement When the measurement is finished, Slide the APP interface to the left. the assessment will be voiced out literal and show on the APP, like in this statement as shown in this picture. picture. You can also check the historical record to know the blood pressure trend in certain period by pressing the button “History”.
  • Page 14: Troubleshooting

    / Automatically power OFF after 2 minutes when not in operation Material Weight / Dimensions 252g / (L) 12.1 x (W) 6.7 x (H) 3.0cm Blood Pressure Measuring Instrument B06T, Micro USB to USB Package Contents charging cable, User Manual...
  • Page 15: Care And Maintenance

    Avoid using rough, coarse-grained materials or solvents/aggressive cleaner. Wipe the cleaned device accurately. Important Notice: Should battery fluid leak from a battery, wipe the battery case with a soft cloth dry. Distributor: Technaxx Deutschland GmbH & Co.KG, Kruppstr. 105, 60388 Frankfurt a.M., Germany...