AccuPulse NIBP Simulator Operation Manuals

Hand held nibp simulator

Advertisement

Operation Manual
Revision History
May 2008 – First Release
January 2010–Rev 01
Notices
Shipping Address: Clinical Dynamics of CT, L.L.C.
10 Capital Drive
Wallingford, CT 06492 U.S.A
Sales & Service:
800.247.6427 (toll free in the U.S.)
Sales E-Mail:
sales@clinicaldynamics.com
Service E-Mail:
service@clinicaldynamics.com
Tech Support:
203.269.0090
Support Email:
support@clinicaldynamics.com
Facsimile:
203.269.3402
Web site:
www.clinicaldynamics.com
Trademarks
AccuPulse™, CalTables Technology™ and CalTables™ are trademarks of Clinical
Dynamics of CT, L.L.C.
Patents
The AccuPulse is protected by U.S. Patent 5,027,641.
Restrictions and Liabilities
The information contained in this manual is subject to change. Any changes made to the
information in this manual will be included in future manuals. No responsibility is
assumed by Clinical Dynamics for the use or reliability of calibrations, software upgrades
or equipment not supplied by Clinical Dynamics or its authorized dealers and authorized
service centers.
The contents of this document, including all figures and drawings, are proprietary
information of Clinical Dynamics of CT, L.L.C., provided solely for purposes of operation,
maintenance or repair, and dissemination for other purposes or publication, or copying
thereof is prohibited without prior written consent by Clinical Dynamics of CT, L.L.C.,
Wallingford, Connecticut.
In the interest of continued product improvement, all specifications are subject to
change without notice.
All Rights Reserved
Copyright © 2009, Clinical Dynamics of CT, L.L.C.. All rights reserved.
No part of this manual may be transmitted, reproduced, translated,
transcribed copied or electronically transmitted without prior written
permission of Clinical Dynamics of CT, L.L.C.. Printed in U.S.A.
Warranty Service & Shipping Instructions
Warranty Service
All repairs on products under warranty must be performed or approved in writing by
Clinical Dynamics Service personnel. Unauthorized repairs will void the warranty.
Assistance
If the product fails to function properly, or if assistance, service or spare parts are
required, contact Clinical Dynamics Customer Service at 800-247-6427 or visit our web
site, www.clinicaldynamics.com and select the SERVICE & SUPPORT MENU. Select
TECHNICAL SUPPORT REQUEST and complete the form. After this form has been
submitted, a Clinical Dynamics' Service Representative will contact you to help solve
your problem. Before contacting Clinical Dynamics, please attempt to duplicate the
problem and to check all accessories to ensure that they are not the cause of the
problem. Prior to calling, please be prepared to provide:
User Manual
AccuPulse Plus – Hand Held NIBP Simulator
(v1.3.x and v2.x.x software)
Operation Manual
AccuPulse™ is a trademark of Clinical Dynamics of CT, L.L.C.
Clinical Dynamics of CT, L.L.C. 10 Capital Drive • Wallingford, CT 06492 U.S.A.
www.clinicaldynamics.com Phone: 203.269.0090 • Facsimile: 203.269.3402
1
• 1. Product name, model number and serial number.
• 2. A complete description of the problem including the conditions under which the
problem occurred. Ideally, a written problem description would be provided, allowing
for more efficient handling of your initial service request and the subsequent
diagnosis and remedy of the problem.
• 3. Your institution's complete name and address with a contact name and phone
number.
• 4. A purchase order number if the product needs non-warranty service or if you are
ordering spare parts.
Returning a Product for Service
Contact Clinical Dynamics Customer Service at 800 247-6427 and provide the
information
listed
above
under
www.clinicaldynamics.com and select the SERVICE & SUPPORT MENU. Select
CALIBRATION / SERVICE REQUEST to fill out a Request for Calibration/Service Form. It
is highly recommended that you pack the product in its original shipping carton and
packing materials, provided that they are still usable. If the original packaging is not
available, select a sturdy corrugated carton large enough to hold whatever items you are
returning, and also to allow 4 to 6 inches of packing material on all sides of the items.
Whether you use the original packaging or an appropriate substitute, please follow these
packing instructions:
1. Remove all hoses, cables, power cords and any other accessories from the instrument
and, if possible, place the instrument is a clean plastic bag. Note:if you are using
substitute packaging, it is essential that you seal the instrument in a clean, static free
plastic bag or in clean bubble wrap in order to prevent packing material from entering
the product.
a)2. Pack only the accessories you are requested to return; place them in a separate bag.
b)3. If you are using substitute packaging, create a foundation of 4 to 6inches of packing
material (either bubble wrap or packing "peanuts") at the bottom of the carton.
c)4. Insert the instrument and the accessory bag into the shipping carton.
d)5. If you are using substitute packaging, fill the 4 sides and the top of the carton with
4 to 6 inches of packing material (either bubble wrap or packing "peanuts"). Ensure
that the instrument and accessory bag are held firmly in place by the packing
material.
e)6. Please place paperwork such as the purchase order, contact info and reasons for
return in the top of the carton.
f) 7. Close the carton and securely seal it with tape; since in most cases the carton will
have been previously used, it may be necessary to reinforce the original tape on the
bottom of the carton.
g) 8. Ship the product via whatever carrier (UPS, FedEx, etc.) is most convenient.
However, please be aware that, depending on where you are shipping from, standard
UPS shipping could take as long as 7 business days. Unless other arrangements are
made, Clinical Dynamics will return the repaired product to you via UPS.
h) 9. Shipping insurance is optional. Claims for damage to the product during shipping
must be initiated by the shipper.
Additional Instructions for International Shipments
Customers outside the United States must include a "pro-forma invoice" for customs
purposes as part of their shipping documents. It is imperative that the name of the
product appears exactly as follows:
AccuPulse Test Equipment
The use of any other product name could add unnecessary delays when shipping
internationally.
Assistance,
or
visit
our
web
site,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NIBP Simulator and is the answer not in the manual?

Questions and answers

Summary of Contents for AccuPulse NIBP Simulator

  • Page 1: Notices, Service & Shipping Instructions

    AccuPulse Plus – Hand Held NIBP Simulator (v1.3.x and v2.x.x software) Operation Manual AccuPulse™ is a trademark of Clinical Dynamics of CT, L.L.C. Clinical Dynamics of CT, L.L.C. 10 Capital Drive • Wallingford, CT 06492 U.S.A. www.clinicaldynamics.com Phone: 203.269.0090 • Facsimile: 203.269.3402 Operation Manual •...
  • Page 2: Table Of Contents

    Clinical Dynamics of CT, L.L.C. warrants to the purchaser that the AccuPulse Non-Invasive Blood Pressure Simulator shall be free from defects in material and workmanship for three years for U.S. customers and a one year warranty for International customers from the date of purchase. To maintain a three year warranty, AccuPulse must be sent directly to Clinical Dynamics, or a service center authorized by Clinical Dynamics, for annual calibration during warranty period.
  • Page 3: Contents

    • Patented NIBP Simulation Technology - U.S. Patent 5,027,641 • AccuPulse always tests with the NIBP Monitor cuff, which can be a major source of Selectable CalTables™: AccuPulse’s new CalTable™ Technology makes it the first problems.
  • Page 4 AccuPulse Handheld device by plugging the power cord into the back of last data collected in that mode.
  • Page 5: Section 4: Basic Operation

    Fax: (203) 269-3402 Email: support@clinicaldynamics.com 2. Assuming you are using an adult cuff, wrap the cuff around the AccuPulse case just as you would wrap it around a patient’s arm. You should be able to fit a pencil between cuff and mandrel. Please see “Wrapping the Cuff Around the Cuff Support” illustration Use the Left/Right Arrow keys to choose the appropriate tab.
  • Page 6: Section 5: Detailed Operation

    0 seconds to 120 seconds if the test time exceeds one screen of time. The Left/Right arrow buttons are only available for test review, they do not scroll while the The default is an automated test. When Start is pressed the AccuPulse Plus pump will test is active.
  • Page 7 PR Adjust Tab BP Test Mode Cont’d Figure PR shows the Pulse Rate adjust tab for the BP Test Screen. The Generic Trim tab is not available when you have selected one of the optional CalTables for use. These are already optimized for specific equipment by Clinical From this screen, the user adjusts the simulated pulse rate.
  • Page 8 AccuPulse Plus unit. This Trim function is provided for customers who want to dial in the AccuPulse for use with specific equipment. The baseline generic oscillometric envelope is not based on any one monitor.
  • Page 9 45 presets of your own design. The user chooses independently the value of each Run Cont. - After the final BP Preset has run, AccuPulse will return to the start and parameter which means you can test and explore behavior under a very wide range of repeat the sequence in a continuous loop.
  • Page 10 The maximum Trim value range is +/- 25 mmHg for both Delta Sys and Delta Dia. This range is limited as needed when the Trim would otherwise meet the MAP point or the end range of the AccuPulse Plus unit. Fig. UD3.
  • Page 11 While this test is running, you can also check the Static Calibration of your NIBP Amplitude range is 1-8 monitor. Compare the AccuPulse manometer in the upper right corner to the pressure Sinewave Motion Frequency range is 1-25 Hz on the NIBP monitor.
  • Page 12 AccuPulse Plus graphs the pressure. When the overpressure valve releases, the by observing the manometer value. The user can release the pressure by pressing reset AccuPulse reports the maximum pressure achieved to the user on the screen in a pop once without losing the results.
  • Page 13 The Cal and SetP functions provide convenient methods of checking accuracy at specific pressure points. The user may also change the units of measurement (for this mode only) so the AccuPulse can be used to verify pressure readings in other applications where mmHg is not the standard unit of measure. Fig M2 Fig M1 Meter mode screen.
  • Page 14 On the AccuPulse use the Up / Down arrow keys to set the target pressure. (Target pressure setting adjustments can also be made while the test is active.) Press Start to begin the test. When the target pressure is reached Accupulse will try to maintain the pressure at this value. Fig. C2 Fig. C1 The corrections made by AccuPulse may cause a slight change just when you don't want it.
  • Page 15: Section 6: Specifications

    While the simulator is in use charging may be slightly slower causing some increase in the time needed to fully recharge the battery. Section 6. Specifications AccuPulse Plus NIBP Simulator Technical Specifications Fig. P1 AccuPulse NIBP CalTables™ Datascope Accutorr Plus GE Medical Dash 4000 F1 (Toggle Sound) Turns the speaker Off/On.
  • Page 16: Section 7: Remote Control

    NOTE: Windows VISTA and Windows 7 do not include a terminal program. Free / Open Cuff Support for Adult cuffs is the AccuPulse case for portability and ease of use. Source terminal applications such as TerraTerm can be easily downloaded. Another Neonate mandrel also supplied solution is to copy Hypertrm.exe and Hypertrm.dll from Windows XP (no install is...
  • Page 17 Using Commands Help The remote-control user of an ApHandheld utilizes the following command to enable This command returns a listing of available commands in the current software. remote-control: These may vary based upon the configuration options loaded in the unit. <>...
  • Page 18 [-50..100] <CR> Auto Leak Test: Setting Test Pressure... Recv: ‘=’ – success >AccuPulse LeakTest Results: ‘#’ – shift value is out-of-range. Start Pressure= 299 mmHg '$' - shift was applied but at a reduced value to remain within simulation 119 Sec. Pressure Drop= 2 mmHg limits.
  • Page 19 Configure Set Pressure (SetP): Set Device ID While in SetP Mode, this sets the target inflation pressure. Note: This command is given for convenience to the end-user. There exists a utility, distributed for free by FtdiChip.com that allows the USB chip inside the APHandheld device Send: <SETP_CFG>...
  • Page 20 Commonly Used Remote Control Commands Short Listing BP Test Settings <> (Initiates the communication, wake simulator comm port) <GET_BP_PARAMS> (unit answers with it's current settings) <KEYPAD_OFF> (locks out front panel keypad use) <KEYPAD_ON> (enables it again) <SET_PRESET> ( 1,1 is ADULT, preset#1 = typically 60/30 ) General Buttons (ADULT presets are 1-7) These button commands operate throughout all modes.

Table of Contents