IQH1S 1U Enclosure SECTION 0 Explanation of Safety Symbols Erklärung der Sicherheitssymbole This symbol refers the user to important information contained in Dieses Symbol weist den Benutzer auf wichtige Informationen the accompanying literature. Refer to manual. hin, die in der begleitenden Dokumentation enthalten sind.
Page 3
IQH1S 1U Enclosure SECTION 0 Simboli di sicurezza: Forklaring på sikkerhedssymboler Questo simbolo indica l'informazione importante contenuta nei Dette symbol gør brugeren opmærksom på vigtig information manuali appartenenti all'apparecchiatura. Consultare il manuale. i den medfølgende manual. Questo simbolo indica che all'interno dell'apparato sono presenti Dette symbol indikerer farlig spænding inden i apparatet.
Page 4
IQH1S 1U Enclosure SECTION 0 Símbolos de Segurança O símbolo triangular adverte para a necessidade de consultar o manual antes de utilizar o equipamento ou efectuar qualquer ajuste. Este símbolo indica a presença de voltagens perigosas no interior do equipamento. As peças ou partes existentes no interior do equipamento não necessitam de intervenção, manutenção ou manuseamento por parte...
Page 5
IQH1S 1U Enclosure SECTION 0 Rack Mounting the Enclosure This product must not be rack mounted using only the front rack ears. When rack-mounting the product, one of the following methods of installation must be used: - Place the unit on a suitably specified, and installed rack shelf and secure the product to the rack via the •...
Page 6
IQH1S 1U Enclosure SECTION 0 Caution Ensure that both power cords are plugged into mains outlets operating from the same phase Safety Standards The IQH1S Enclosure conforms to the following standards: EN60950: 2000 Safety of Information Technology Equipment. cULus Listed Professional Video Equipment File No.
Page 7
SECTION 0 About this Manual This manual contains information for the Installation of the IQH1S 1U Enclosure and is intended for use by trained engineering staff. Update/revision sheets should replace existing pages when supplied by the agent or Snell & Wilcox Ltd.
IQH1S 1U Enclosure SECTION 0 Table of Contents SECTION Installation Power Connections ......................1.1 Opening and Closing the front panel.................. 1.1 Power On/Off switch......................1.2 Front panel Connections ....................1.2 Communication Connections ..................... 1.3 Hex switches and indicators....................1.3 Installing/Removing a Module .................... 1.5 Control Panels........................
Page 9
IQH1S 1U Enclosure SECTION 0 Product Support Procedure If you experience any technical or operational difficulties with a Snell & Wilcox product please do not hesitate to contact us or utilize our online form to request assistance. There is a lot of information you can give us that will enable us to diagnose your problem swiftly. Please read the following guidelines, as these suggestions will help us to help you.
Page 11
IQH1S 1U Enclosure SECTION 0 Manual Revision Record Date Version No. Issue No. Change Comments 030403 First Issue released 090605 Complete new manual issued Reference to Module power label removed from page 1.6 and power to 60 W pages 1.6 & 2.1...
IQH1S 1U Enclosure SECTION 1 Installation Important Installation Notice To fully conform with EMC standards modules must be correctly installed in the mainframes paying particular attention to the following: 1. A modular card must only be plugged into a rear connection panel specifically designed for that module 2.
IQH1S 1U Enclosure SECTION 1 POWER ON/OFF SWITCH The power ON/OFF switch is located behind the drop-down front panel in the left-hand corner. Power ON will be indicated by the illumination of the LED on the front panel. FRONT PANEL CONNECTOR...
IQH1S 1U Enclosure SECTION 1 COMMUNICATION CONNECTIONS IAL OUT Remote 100-240V~ 60/50 Hz This 9 pin `D' connector on the rear panel allows 1.8A the unit to be connected to the RollCall 485 T2A H 250V network communications system. Note that RS485 interconnections should be SERIAL IN pin to pin and only be used for Snell &...
Page 15
IQH1S 1U Enclosure SECTION 1 THE GATEWAY CARD Front Panel RollNet Connector FRONT PANEL CONNECTOR Front Panel When an active control panel is fitted to the unit, Connector this connector carries the communication signals between the mainframe and the front panel.
Page 16
IQH1S 1U Enclosure SECTION 1 LED INDICATORS This green LED indicates that the +5V ex Switches supply is present. This green LED indicates that the -5V Error supply is present. Error This red LED indicates that the processor is running outside of its normal operational parameters.
IQH1S 1U Enclosure SECTION 1 INSTALLING/REMOVING A MODULE Internal View of 1U Mainframe. Rear of 1U Mainframe fitted with two double width Modules and two single width Modules COMPOSITE OUTPUT SERIAL OUT AES AUDIO OUT SERIAL IN 2 100-240V~ 60/50 Hz 1.8A...
Page 18
IQH1S 1U Enclosure SECTION 1 Installing a New Module Warning Ensure that the power supply is switched OFF and the mains power connection at the rear of the unit is removed before these operations are attempted. 1. Before installing a new module consult page 1.5 “Installing/Removing a Module”...
IQH1S 1U Enclosure SECTION 1 Control Panels A mainframe and the modules that it contains, may be controlled by the following methods:- 1. Locally, by use of an active front panel (the control panel) for the 1U system 2. Remotely, by use the same control panel as in (1) above, connected by a single cable assembly 3.
Page 20
IQH1S 1U Enclosure SECTION 1 RollCall Network System Details The IQ Modular system has a flexible and yet powerful remote control system. The units in the system are joined via a high-speed network and each box enclosure (including active front panels) is a node on the network.
Page 21
IQH1S 1U Enclosure SECTION 1 RollNet RS485 Differential Interface Sections of the coaxial network can be joined using the RS485 bus. The RS485 connections are limited to shorter distances but are multi-drop allowing a rich combination of network configurations. The combined total number of units across the coaxial network and the RS485 bus is still 255 nodes and the total network length can be up to 1500m.
Page 22
IQH1S 1U Enclosure SECTION 1 RS485 Differential Interface This interface allows bus connections to internal pieces of equipment such as front panels. It is a multi-drop differential bus with a data rate of 2.5 Mb/s. The data format used on this bus is identical to that used on the coaxial network, hence can provide a natural hub between coaxial sections.
Page 23
IQH1S 1U Enclosure SECTION 2 Technical Profile Features Inputs/Outputs Preset Controls RollCall™ Remote Control..BNC connector Unit address code set switches 2 Hex switches 0 to F RS422/485 Remote Control9-pin D-type connector Communications mode switch Active Front Panel Controls Select RollCall™ 485 or RS422 Dedicated Push Buttons for:Home;...
Page 25
IQH1S 1U Enclosure SECTION 0 Explanation of Safety Symbols Légende : This symbol refers the user to important information contained in Ce symbole indique qu'il faut prêter attention et se référer the accompanying literature. Refer to manual. au manuel. This symbol indicates that hazardous voltages are present inside.
Page 26
IQH1S 1U Enclosure SECTION 0 Erklärung der Sicherheitssymbole Simboli di sicurezza: Dieses Symbol weist den Benutzer auf wichtige Informationen Questo simbolo indica l'informazione importante contenuta nei hin, die in der begleitenden Dokumentation enthalten sind. manuali appartenenti all'apparecchiatura. Consultare il manuale.
Page 27
IQH1S 1U Enclosure SECTION 0 Forklaring på sikkerhedssymboler Símbolos de Segurança Dette symbol gør brugeren opmærksom på vigtig information O símbolo triangular adverte para a necessidade de consultar o i den medfølgende manual. manual antes de utilizar o equipamento ou efectuar qualquer ajuste.
Page 28
IQH1S 1U Enclosure SECTION 0 Products employing Lithium batteries CAUTION This equipment contains a lithium battery. There is a danger of explosion if this is replaced incorrectly. Replace only with the same or equivalent type. Dispose of used batteries according to the instructions of the manufacturer.
Page 29
IQH1S 1U Enclosure SECTION 0 Rack Mounting the Enclosure This product must not be rack mounted using only the front rack ears. When rack-mounting the product, one of the following methods of installation must be used: - Place the unit on a suitably specified, and installed rack shelf and secure the product to the rack via the •...
Page 30
SECTION 0 About this Manual This manual contains information for the Installation of the IQH1S 1U Enclosure and is intended for use by trained engineering staff. Update/revision sheets should replace existing pages when supplied by the agent or Snell & Wilcox Ltd.
Page 31
IQH1S 1U Enclosure SECTION 0 Table of Contents SECTION Description and Features Description ......................... 1.1 Features ..........................1.1 Specifications Installation Important Installation Notice....................3.1 Power connections...................... 3.1 Power on/off switch..................... 3.1 Front panel connector ....................3.1 Communications mode switch ..................3.1 Communication connections..................
Page 32
IQH1S 1U Enclosure SECTION 0 Operation 1U ACTIVE CONTROL PANEL ....................4.1 GENERAL INFORMATION..................4.1 The Menu System..................... 4.1 THE LCD DISPLAY WINDOWS ................. 4.2 LED Indicators ....................4.4 Dedicated Push Buttons ................... 4.4 CONTROL SYSTEM OVERVIEW ..................4.7 Front Panel Setup via the Front Panel Menu System............. 4.8 SETUP MENU SYSTEM.....................
Page 33
IQH1S 1U Enclosure SECTION 0 Product Support Procedure If you experience any technical or operational difficulties with a Snell & Wilcox product please do not hesitate to contact us or utilize our online form to request assistance. There is a lot of information you can give us that will enable us to diagnose your problem swiftly. Please read the following guidelines, as these suggestions will help us to help you.
Page 35
IQH1S 1U Enclosure SECTION 0 Manual Revision Record Date Version No. Issue No. Change Comments 030403 First issue released 090605 New issue released Power to 60 W page 2.1 Updated section 4 041006 For new software New issue released 231106 Page 3.4 LED status data added...
IQH1S 1U Enclosure SECTION 1 Description This 1RU enclosure accepts up to 6 single width The ‘shoebox’, containing the Active Front Panel, is modules. designed for fitting into a control desk. However, the 1RU frame can also be fitted with an 'Active It is fitted with a RollCall gateway card and single Front Panel' to enable remote control if required.
IQH1S 1U Enclosure SECTION 3 Installation Important Installation Notice To fully conform with EMC standards modules must be correctly installed in the mainframes paying particular attention to the following: 1. A modular card must only be plugged into a rear connection panel specifically designed for that module 2.
IQH1S 1U Enclosure SECTION 3 COMMUNICATION CONNECTIONS Remote 100-240V~ 60/50 Hz This 9 pin `D' connector on the rear panel allows 1.8A the unit to be connected to the RollCall 485 T2A H 250V network communications system. Note that RS485 interconnections should be ERIAL IN pin to pin and only be used for Snell &...
IQH1S 1U Enclosure SECTION 3 THE GATEWAY CARD Front Panel RollNet Connector FRONT PANEL CONNECTOR Front Panel When an active control panel is fitted to the unit, Connector this connector carries the communication signals between the mainframe and the front panel.
IQH1S 1U Enclosure SECTION 3 LED INDICATORS This green LED indicates that the +5V supply is present. ex Switches This green LED indicates that the -5V supply is present. Error Error This red LED indicates that the processor is running outside of its normal operational parameters.
IQH1S 1U Enclosure SECTION 3 Control Panels A mainframe and the modules that it contains, may be controlled by the following methods:- 1. Locally, by use of an active front panel (the control panel) for the 1U system 2. Remotely, by use the same control panel as in (1) above, connected by a single cable assembly 3.
IQH1S 1U Enclosure SECTION 3 RollCall Network System Details The IQ Modular system has a flexible and yet powerful remote control system. The units in the system are joined via a high-speed network and each box enclosure (including active front panels) is a node on the network.
IQH1S 1U Enclosure SECTION 3 RollNet RS485 Differential Interface Sections of the coaxial network can be joined using the RS485 bus. The RS485 connections are limited to shorter distances but are multi-drop allowing a rich combination of network configurations. The combined total number of units across the coaxial network and the RS485 bus is still 255 nodes and the total network length can be up to 1500m.
IQH1S 1U Enclosure SECTION 3 RS485 Differential Interface This interface allows bus connections to internal pieces of equipment such as front panels. It is a multi-drop differential bus with a data rate of 2.5 Mb/s. The data format used on this bus is identical to that used on the coaxial network, hence can provide a natural hub between coaxial sections.
IQH1S 1U Enclosure SECTION 4 1U ACTIVE CONTROL PANEL GENERAL INFORMATION Modules may be controlled by means of a local, front control panel, by a similar panel at a remote location or a computer interface. Communication is via a wired network system called RollCall™ and many units may be controlled.
IQH1S 1U Enclosure SECTION 4 THE LCD DISPLAY WINDOWS Control Window The Control window displays all Selection Menus and sub-menus. The selection is made by pressing the button adjacent to the required item. SYMBOLS Symbols used in this window have the following...
Page 48
IQH1S 1U Enclosure SECTION 4 Information Window The Information window has four lines of text indicating current selections various information messages. Note that some units will overwrite the information window indication with their own messages. Under these conditions the control panel will only be able to write to the information window when the unit has been disconnected.
IQH1S 1U Enclosure SECTION 4 LED Indicators The green LED indicator on the front panel marked POWER will be illuminated when the unit is powered-up. The LED marked ACTIVE will be illuminated when the front panel is connected to and communicating with a unit.
Page 50
IQH1S 1U Enclosure SECTION 4 SAVE This button reveals a list of 8 memory locations and allows the address of the currently active module to be saved to one of these memory locations by pressing the button adjacent to the desired memory location number.
Page 51
IQH1S 1U Enclosure SECTION 4 The Display Select buttons allow the Information Window to display two different sets of information: Identity Codes The first line will show the unit name The second line will show the unit address code and the RV (RollCall Version)
IQH1S 1U Enclosure SECTION 4 CONTROL SYSTEM OVERVIEW Operation uses a system of menus displayed in two The RollCall™ control system allows RollCall™ LCD windows on the active front panel. compatible modular cards fitted into 1U or 3U main frames and dedicated units, to be controlled by...
IQH1S IU Enclosure SECTION 4 Front Panel Setup via the Front Panel Menu System MAIN MENU MAIN MENU MAIN MENU (Supervisor Level) (Engineering Level) (User Level) F/Panel Address F/Panel Address F/Panel Name F/Panel Name Auto Connect Unit Address: Default Unit FF (Hex) Backlight Backlight...
Page 54
IQH1S IU Enclosure SECTION 4 SETUP MENU SYSTEM F/Panel Address The address of this control panel will be displayed SETUP as a 2-digit hexadecimal code. Pressing this button displays a list of front panel F/Panel Address options in the CONTROL window. Examples of these are shown in the `Setup Menu System' Unit Address: drawing on the previous page.
Page 55
IQH1S IU Enclosure SECTION 4 F/Panel Name The control panel may be given a name using this function (e.g. Edit Suite, Studio 2 etc.) Unit Name Edit Suite ◀ ◀ ◀ ◀ ▶ ◀Clear F/Panel Name Save ▶ ◀Preset Unit Name: Front Panel Clear Preset...
Page 56
IQH1S IU Enclosure SECTION 4 BackLight Default Unit On power-up the default unit will be automatically Backlight connected, its menus retrieved and will be ready for active control. Backlight Mode AUTO Save Default Unit Selecting this function allows the backlighting of the Default Unit :06 Name display windows to set, by rotating the spinwheel,...
Page 57
IQH1S IU Enclosure SECTION 4 Network Lock Controls This function allows the front panel to be `hidden' To set this function enter at Supervisor level, select from the network system. In the Hide mode this the Lock Controls item to reveal the dialogue box. front panel will not appear in the Module List displayed on other control panels in the system.
Page 58
IQH1S IU Enclosure SECTION 4 Access Level Selection levels are: The setup of the active front panel may be USER Provides access to basic user accessed at various levels. At the highest level controls. (Supervisor) access is allowed to all functions. This level may only be accessed by entering a ENGINEER Provides access to more controls...
IQH1S IU Enclosure SECTION 4 Front Panel Setup via the RollCall Control Templates Control Name The control panel may be given a name using this function (e.g. Edit Suite, Studio 2 etc.) The maximum number of characters, including spaces, is 19 and may consist of letters and numbers (ASCII Characters) This function allows the name of the front panel as seen on the network, to be changed.
Page 60
IQH1S IU Enclosure SECTION 4 Auto Connect This function allows a number of units to be automatically connected to the control panel at power-up. Up to 16 units may be designated in this way by assigning a number to them. (00 to 15) Note that these numbers are also used to assign the default unit.
IQH1S IU Enclosure SECTION 4 Setup User Levels The setup of the active front panel may be accessed at various levels. At the highest level (Supervisor) access is allowed to all functions. This level may only be accessed by entering a password.
IQH1S IU Enclosure SECTION 4 RollCall Control Templates for the IQHS1U Enclosure RCIF Control This function displays information about the controllers for each slot. Any of the 6 slots may be interrogated and the following information displayed. Packet Count When the modules receive commands from control clients the number of commands are counted.
Page 63
IQH1S IU Enclosure SECTION 4 Control (Continued) Active Front Panels and RollCall PC programs use a RollCall connection to control a module. RollTrack does not use a connection, it uses Blind control. Blind Control is the ability to control a unit without a connection.
IQH1S IU Enclosure SECTION 4 Slots This function allows each slot to be named and interrogated. Overview Slot Installed Installed Number Unit ID Unit Type Editable Name Bound Type ID Installed Unit Name Bound Type ID This shows what is fitted in the slot. The Bound Type function allows the slot to be associated with a particular type of module (e.g.
Page 65
IQH1S IU Enclosure SECTION 4 Intentionally Empty Slot If the slot should not have a unit installed the Installed Unit Name widow will show No Unit Fitted and the Installed Unit ID window will show No Unit. However, the editable name widow will show the intended name and the Bound Type ID widow will show the intended ID.
Page 66
IQH1S IU Enclosure SECTION 4 Incorrect Module Fitted If a module is fitted that does not match the bound type then the editable name will not be used and the generic type and slot number will appear in the network browser. Correct Module Fitted If a module is fitted that does match the bound type then the editable name is used in the network...
IQH1S IU Enclosure SECTION 4 Setup This function allows various system functions to be set up. This function allows various system functions to be setup. Unit Name This allows the unit to be given a meaningful name. Serial Number This shows the serial number of the unit. Hardware Version This shows the version number of the hardware used in the Gateway.
Page 68
IQH1S IU Enclosure SECTION 4 Setup (cont) Net Show This function allows a unit to be `hidden' from the network system. When netshow is active the unit broadcasts its presence. Note that if the unit address is changed Netshow will automatically be turned On. Allow Blind Control If the Gateway will be controlled by Blind Control then Allow Blind Control must be enabled.
Page 69
IQH1S IU Enclosure SECTION 4 Setup (cont) Pass WAN Packets SP_IAM This controls whether the Gateway passes wide area I_AM packets from the serial port to the RollCall Network. Normally this is enabled to allow PCs attached to the serial port to be located by other units, but it may be disabled if you wish to control the flow of I_AM packets through a system.
IQH1S IU Enclosure SECTION 4 Log Server This allows the characteristics of the logging server to be specified. LogServer Name The Logging Server to be used may be named by editing the text string in the text window. symbol represents the Preset function and will return the name to LogServer.
IQH1S IU Enclosure SECTION 4 Logging This menu determines the information made available for logging. IQH1SOPS 23/11/06 www.snellwilcox.com Version 1 Issue 4 4.26...
IQH1S IU Enclosure SECTION 4 Logging Fields Field Name Field Name Valid Field Values Usage Description Description Format is standard S&W serial number Serial Number Serial Number consisting of character ‘S’ followed by eight digits, e.g. “S12345678” Hardware Format: “<PCB name>/<mod strike>”, e.g. VERSION Version Number Version...
Page 73
IQH1S IU Enclosure SECTION 4 Field Name Field Name Valid Field Values Usage Description Description Temperature in Celsius Temperature TEMP_1_CELSIUS Number Temperature will be blank if the temperature in ° C sensor is not enabled. State of Running average of bus errors, 0 would indicate Number of bus errors MODULE_COMMS module...
IQH1S IU Enclosure SECTION 4 Statistics This function can display various errors that may occur within a system. In the event of a problem these error messages may be quoted to assist debugging. Enable Net Stats This item must be checked to enable the errors to be updated.
Log to Software Version Logging Disabled Named LogServer Controller Any LogServer Controller 0000:2F:00 Hardware Version Preset RCIF1U Serial Number Seial Number Xxxxxxxx Unit Name Unit Name IQH1S 1U RCIF Menu Clear Preset System IQH1SOPS 23/11/06 www.snellwilcox.com Version 1 Issue 4 4.30...
IQH1S IU Enclosure SECTION 4 THE IQH1S ENCLOSURE RCIF MENU SYSTEM Slots (See drawing on previous page) This function allows each slot to be named and GENERAL INFORMATION interrogated. The RCIF Menu System allows access to setting of Slots RCIF system parameters. All operational parameters and selections may then be made using a system of Slot 1...
IQH1S IU Enclosure SECTION 4 Name Statistics This allows a slot to be given a user name e.g. This function can display various errors that may “Chan 1 Encode” and so long as the correct card occur within a system. stays in that slot this name will be used, as defined by matching Installed Unit ID and Bound Type ID.
IQH1S IU Enclosure SECTION 4 Recons. Logging This item indicates any errors occurring during the This menu determines the information made communication of connection data in the Rollcall available for logging. network. Logging Condition Error value Log Server Normal 0 or constant value VERSION= Log OS Version Fault...
Page 79
IQH1S IU Enclosure SECTION 4 Log Server Last Time Addr This allows the characteristics of the logging server This shows the address from which the last time to be specified. packet was received. This can be useful in configuring complex networks. Log Server Time From Logger Log to...
IQH1S IU Enclosure SECTION 4 System/Setup Software version This function allows various system functions to be Software Version set up. Software Version System/Setup Unit Name Serial Number This shows the software version installed. Hardware Version Software Version Build Number Build Number Loader Version NetShow Allow Blind Control...
Page 81
IQH1S IU Enclosure SECTION 4 Allow Blind Control Serial Mode Blind Control is the ability to control a unit without a This item shows the current operating mode of the connection. Active Front Panels and RollCall PC serial port (RS422, RS232 or RS485). programs use a RollCall connection to control a module.
IQH1S IU Enclosure SECTION 4 Start Time Control This shows the date and time that the unit was ]ast This function displays information about the restarted. controllers for each slot. Start Time Control Start Time Slot 1... Slot 2... Slot 3... Slot 4...
Page 83
IQH1S IU Enclosure SECTION 4 Last Blind User Packet Statistics This will display the address of last controller to When the modules receive commands from control send the module a blind control packet. clients the number of commands are counted. Last Blind User Packet Statistics Last Blind User...
IQH1S IU Enclosure SECTION 4 Menu System - 1U Enclosure Configured as a Shoebox Main Menu System/Setup Statistics System Stats... Logging... Unit Name Reset Net Stats Serial Number Enable Net Stats Hardware Version Length Errs Software Version Recons Logging Build Number Module Comms Errors Loader Version Bad Packet Errs...