TCF 14HA1B Installation, Operation & Maintenance Manual

Ha series; hab series fiberglass wall mount ventilators

Advertisement

Quick Links

Throughout this manual, there are a number of HAZARD WARNINGS that must be read and adhered to in order
to prevent possible personal injury and/or damage to equipment. Two signal words "WARNING" and "CAUTION"
are used to indicate the severity of a hazard and are preceded by the safety alert symbol.
WARNING
Used when serious injury or death MAY result from misuse or failure to follow specific instructions.
CAUTION
Used when minor or moderate injury or product / equipment damage MAY result from misuse or failure to follow
specific instructions.
It is the responsibility of all personnel involved in installation, operation and maintenance to fully understand the
Warning and
Caution procedures by which hazards are to be avoided.
Receiving
The HA/HAB ventilator is shipped in two parts:
1. Fan housing assembly complete with fiberglass inlet
venturi to the wheel and complete motor and drive
assembly.
2. Flanged extruded aluminum louver assembly.
Duct adapter and companion angles are shipped loose
if unit is for inline application.
Inspect cartons or crates carefully before signing a
delivery receipt for the carrier. If any damage is
apparent, note it on the carrier's receipt so that a claim
can be filed against the carrier through your usual
channels.
Handle the units carefully while delivering to installation
location. Use ordinary care in unpacking the units. If the
units, when unpacked, appear to be damaged in a way
that could not be determined at the time of delivery,
notify the carrier that concealed damage has been
discovered and insist on inspection by the carrier. Obtain
a copy of carrier's inspection report showing the
concealed damages so that a claim can be filed through
your usual channels.
Study the attached installation prints carefully. Inspect
the units carefully for identification marks, fan rotation
symbols, etc.
HA/HAB Fiberglass
Wall Mount Ventilators
INSTALLATION, OPERATION & MAINTENANCE MANUAL
©1997 – 2018 Twin City Fan Companies, Ltd.
Installation
Wall Application
1. Remove wood shipping supports from fan assembly
(see Figure 1).
2. Locate and provide hole in the wall
the fan housing (see Figure 2). This will provide an
opening for the electrical wiring into the unit.
3. Anchor the box in the wall, keeping a minimum of
2
3
" between the outside wall and any part of the
8
box or the power assembly.
4. Fasten the flanged extruded louver to the exterior
wall.
Inline Application
1. Remove wood shipping supports from fan assembly
(see Figure 1).
2. Attach duct adapter and companion angles to unit
per Figure 3 with fasteners supplied.
3. Before anchoring the unit to the ductwork, check line
voltage and current characteristics outlined in previous
section.
4. Fasten the flanged extruded louver to the exterior wall
wherever the outlet of the ductwork ends.
For easy maintenance of the ventilator inline, provide a
drop-out section between ductwork and duct adapter
(see Figure 3).
IM-3100
August 2015
1
" larger than
2

Advertisement

loading

Summary of Contents for TCF 14HA1B

  • Page 1 HA/HAB Fiberglass IM-3100 Wall Mount Ventilators August 2015 INSTALLATION, OPERATION & MAINTENANCE MANUAL Throughout this manual, there are a number of HAZARD WARNINGS that must be read and adhered to in order to prevent possible personal injury and/or damage to equipment. Two signal words "WARNING" and "CAUTION" are used to indicate the severity of a hazard and are preceded by the safety alert symbol.
  • Page 2: Maintenance

    Table MODEL MOTOR MAXIMUM FAN RPM 12HA1B, 2B, 3B 1738 14HA1B, 2B, 3B 1468 3. On three-phase units check and calculate phase 14HA4B 1615 unbalance as follows: 14HA5B 1849 18HA1B, 2B % Voltage Unbalance = 100 x max.
  • Page 3 Motors require no lubrication for 10 years of normal Figure 1. Removal of Wood Shipping Supports operation. The inlet venturi is molded shock-resistant, bonded, reinforced fiberglass and will require no maintenance. Housing Wall Application 1. Servicing or inspecting the unit can be accomplished from the exterior by removing the flanged extruded louver and from the interior of the building by removing the fiberglass inlet (see Figure 2).
  • Page 4 Figure 3. Inline Application Wiring By Others Louver Assembly Duct Adaptor on Exterior Wall Ductwork By Others (Shipped Loose With Fasteners) Ductwork By Others Companion Angles (Shipped Loose) With Fasteners) Access to Power Pack of Inline Unit By Removing 4 Fasteners Dropout Section of Duct For Easy Maintenance (By Others) Twin ...
  • Page 5: Maintenance Record

    MAINTENANCE Location Serviced by Job Name: _______________________ Organization: _____________________ Address: _________________________ Address: _________________________ City / State / Zip: __________________ City / State / Zip: __________________ Telephone: ( ) _________________ Telephone: ( ) _________________ Contact: _________________________ Contact: _________________________ Fan Nameplate Information Motor Nameplate Information Model: _____________________ HP ____ Rpm _____ Volts _________...
  • Page 6 TWIN CITY FAN & BLOWER | WWW.TCF.COM 5959 Trenton Lane N | Minneapolis, MN 55442 | Phone: 763-551-7600 | Fax: 763-551-7601...