FIRE FEATURES FIREBOWL 45 L Owner's Manual

Manual pilot ingnition

Advertisement

Quick Links

MANUAL PILOT IGNITION
FIREBOWL OWNER'S MANUAL
DO NOT DISCARD THIS MANUAL
• Important operating and maintenance instructions included.
• Read, understand and follow these instructions for safe installation and operation.
• Leave this manual with party responsible for use and operation.
!
DANGER:
IF YOU SMELL GAS:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and
immediately call your gas supplier or fire department.
!
WARNING:
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
!
WARNING:
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this gas appliance.
!
CARBON MONOXIDE HAZARD
DANGER
This appliance can produce carbon monoxide which has no odor.
Using it in a enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent, or home.
TEST CERTIFIED BY OMNI TEST LABORATORIES
ANSI Z21.97-2012/ CSA 2.41-2012
CGA 2.17-M91 (2009)
C
388-O-01b-5
MODELS: 45
54
COLOMBO CONSTRUCTION CORP
68 L, LL, & NL
!
WARNING:
FOR OUTDOOR USE ONLY
342 Park AVE Brooklyn, NY 11205
T 718.399.2233 F 718.399.2237 M 212.334.5069
REVISED: 07.27.2018
firefeatures.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FIREBOWL 45 L and is the answer not in the manual?

Questions and answers

Summary of Contents for FIRE FEATURES FIREBOWL 45 L

  • Page 1 MANUAL PILOT IGNITION FIREBOWL OWNER’S MANUAL MODELS: 45 68 L, LL, & NL • • DO NOT DISCARD THIS MANUAL • Important operating and maintenance instructions included. • Read, understand and follow these instructions for safe installation and operation. • Leave this manual with party responsible for use and operation. DANGER: IF YOU SMELL GAS: 1.
  • Page 3: Table Of Contents

    MANUAL PILOT FIREBOWL TABLE OF CONTENTS Listing Information Purchase Agreement Warnings Warranty Information Overview Size Chart Components Control Panel Venturi/Orifice Burner/Pilot Pilot Guard/Pilot Sighting Tube Mounting Clearances Gas Connection Ignition Rocks Maintenance Replacement Parts Side Mounted Ignition 68 NL & LL Firebowl •...
  • Page 4 Mailing Address: P.O. Box 301367 Portland, OR 97294 including, the American National Standards Institute Phone: 503.643.3788 Fax: 503.643.3799 (ANSI), the Standards Council of Canada (SCC), the In- Email: contact@omni-test.com FIRE FEATURES A Division of Model: Firebowl COLOMBO CONSTRUCTION CORP ANSI Z21.97-2012/CSA 2.41-2012...
  • Page 5: Purchase Agreement

    FIREFEATURES COLOMBO CONSTRUCTION CORP 342 Park AVE Brooklyn, NY 11205 T 718.399.2233 F 718.399.2237 M 212.334.5069 • • firefeatures.com info@firefeatures.com • DECORATIVE GAS APPLIANCE PURCHASE AGREEMENT Purchase agreement dated _____________ , 2018 between Colombo Construction Corporation (the “Com- pany”) with a principal office located at 342 Park Avenue, Brooklyn, New York 11205 and _____________ (the “Buyer”), located at...
  • Page 6 Additional Charges: No allowance shall be made to Buyer for any transportation, labor charges or parts, adjustments or repairs, or any other work, without the Company’s prior written authorization. Pay- ment for modifications requested by Buyer shall be due upon written acceptance by the Company of such modifications.
  • Page 7 Model: Firebowl only ANSI Z21.97-2012/CSA 2.41-2012 Type of Gas: Natural Gas (NG), Liquid Propane (LP) Report # 388-0-01b-5 ORIFICE SIZES: 45” Models: LP Maximum BTU = 150,000 w. #26 DMS orifice @ 11” W.C. Inlet - 10” W.C. Manifold NG Maximum BTU = 150,000 w. #6 DMS orifice @ 7” W.C. Inlet - 6” W.C. Manifold 54”...
  • Page 8 Partial Shipments: The Company may make and invoice partial shipments of components of the Ap- pliance or defer manufacture or delivery of the Appliance only if, when and to the extent agreed to in writing by Buyer. Cancellation: Orders are not subject to cancellation, complete or partial, without the Company’s consent.
  • Page 9 SCHEDULE A: GENERAL SPECIFICATIONS: Prior to installation, the Project Manager, as well as the mechanical, structural and fire safety engineers, must first approve the specifications of this low-pressure decorative gas appliance. It must be installed on site, pressure and leak checked by a certified gas technician as per national and local, building, gas, fire, and safety codes and ordinances.
  • Page 10 The exterior or interior installation, use and maintenance of ignition systems must be made in accordance with the manufacturer’s instructions, warranties, specifications and recommendations. Failure to do so may result in the failure of the ignition system to function properly, voiding the manufacturer’s warranty and the crea- tion of hazardous conditions.
  • Page 11 chaser and must be taken extremely seriously. The purchaser further agrees to take the necessary precautions to prevent children and other unqualified per- sons from being able to ignite or breath in closed quarters the propane or natural gas required to operate the appliance, as well as to post or secure the appliance from unknowing persons contacting the appliance while it is in operation, or hot, either during or after use.
  • Page 12: Warnings

    WARNINGS MANUAL PILOT FIREBOWL FOR YOUR SAFETY READ BEFORE FOR YOUR SAFETY READ BEFORE FOR YOUR SAFETY READ BEFORE FOR YOUR SAFETY READ BEFORE OPERATING OPERATING OPERATING OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUC- perative that control compartment, burners and circulating air TIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT passageways of the appliance be kept clean to provide for ad- CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR...
  • Page 13 WARNINGS MANUAL PILOT FIREBOWL FOR YOUR SAFETY READ BEFORE OPERATING Do not operate or place appliance on, near, or in the vicinity The firebowl does not come supplied with rocks. 100- 200 of any flammable materials, vapors, liquids or accelerants of lbs.
  • Page 14 WARNINGS/ MANUAL PILOT FIREBOWL WARRANTY ! ! ! ! FOR YOUR SAFETY READ BEFORE FOR YOUR SAFETY READ BEFORE FOR YOUR SAFETY READ BEFORE FOR YOUR SAFETY READ BEFORE OPERATING OPERATING OPERATING OPERATING LP SPECIFICATIONS: the gas supply tank in the enclosure can be leak tested inside the enclosure.
  • Page 15: Overview

    OVERVIEW MANUAL PILOT FIREBOWL GENERAL SPECIFICATIONS The firebowl must be installed on site, pres- sure and leak checked by a certified gas technician as per national and local, build- ing, gas, fire, and safety codes and ordi- nances. This appliance comes supplied with a Max- 54LL Firebowl itroll 325-5AL Individual low pressure appli- ance regulator.
  • Page 16: Size Chart

    SIZE CHART MANUAL PILOT FIREBOWL LIP OPTIONS 45” DIAMETER LL = LITTLE LIP NL = NO LIP 54” DIAMETER LL = LITTLE LIP NL = NO LIP 68” DIAMETER L = LIP NL = NO LIP Side Mounted Ignition 68 NL & LL Firebowl •...
  • Page 17: Components

    COMPONENTS MANUAL PILOT FIREBOWL EXPLODED VIEW MODEL SHOWN: 54LL LEGEND Feet Burner Pilot Sighting Tube Pilot Guard Pilot Assembly Venturi Air Mixer Venturi Air Shutter Orifice 1/2” Connection to Control Valve Gas Valve Control Knob Baso Safety Valve Maxitrol 325-5AL Low Pressure Regulator Control Panel Side Mounted Ignition 68 NL &...
  • Page 18: Control Panel

    CONTROL MANUAL PILOT FIREBOWL PANEL FRONT PLATE LEGEND Burner Plate Pilot Lighting Button Control Panel Gas Valve Control Knob BEHIND THE FRONT PLATE LEGEND H15DA-3C Baso Safety Valve 3/4” Ball Valve (Flame adjustment) K16BA-48 #22 Baso Thermocouple 1/4” Pilot Gas Feed 1/2”...
  • Page 19: Venturi/Orifice

    VENTURI/ MANUAL PILOT FIREBOWL ORIFICE VENTURI/ORIFICE ASSEMBLY LEGEND 90M Stainless Steel Venturi Air Mixer Venturi Air Shutter 1/4” Brass Orifice 1/4” NPT Brass Compression Tube Fitting Elbow Adapter OXYGEN INTAKE ADJUSTMENT The Venturi is factory set with a set screw. Before operation, check to see that the Ven- turi is set in the position to the left.
  • Page 20: Burner/Pilot

    BURNER/PILOT MANUAL PILOT FIREBOWL BURNER Special 150,000 to 300,000 BTU cross style “Yellow Flame” burner tested prior to shipping LEGEND Burner Mounting Leg 1” Schedule 40 Stainless Steel Cross Burner 90M Stainless Steel Venturi Air Mixer PILOT The Pilot Assembly is located under the Pilot Guard.
  • Page 21: Pilot Guard/Pilot Sighting Tube

    PILOT GUARD MANUAL PILOT FIREBOWL • PILOT SIGHTING TUBE PILOT GUARD The Pilot Assembly is located under the Pi- lot Guard which keeps the lava rocks from damaging the pilot assembly. PILOT SIGHTING TUBE The Pilot Sighting Tube allows you to guide the torch to the proper location to light the pilot when the firebowl is filled with rocks.
  • Page 22: Mounting

    MOUNTING MANUAL PILOT FIREBOWL ATTACHING THE BOWL You’ll need to have a hammer, a socket wrench and a 8” x1/2” Expansion-Anchor-Bolt Drill 1/2” hole 5 1/2” deep in a stable mount- ing platform: recommended a 20” diameter sonotube concrete footing. Hammer Expansion-Anchor-Bolt into the hole.
  • Page 23 MOUNTING MANUAL PILOT FIREBOWL MOUNTING OVER COMBUSTIBLE MATERIALS A firebowl can be mounted over combustible materials when a heat shield is installed. The heat shield comes welded to the ball feet the firebowl sits on. A FIREBOWL EQUIPPED WITH A LOWER HEAT SHIELD IS MOUNTED IN THE SAME MANNER AS A FIREBOWL WITHOUT.
  • Page 24: Clearances

    CLEARANCES MANUAL PILOT FIREBOWL THIS GRAPHIC SHOWS CLEARANCE TO COMBUSTABLES WITHOUT THE USE OF A LOWER HEAT SHIELD ATTACHING THE BOWL Showing clearances to walls and ceilings. COMBUSTIBLE CEILING -Bottom surface of the bowl will reach temperatures of 290°F -Ceiling temperature at 12’ distance 210°F -Wall temperature 205°F 144"...
  • Page 25 CONNECTION MANUAL PILOT FIREBOWL GENERAL SPECIFICATIONS The firebowl must be installed on site, pressure and leak checked by a certified gas technician as per national and local, building, gas, fire, and safety codes and ordinances. The Firebowl comes supplied with a Maxitrol 525-5AL Individual low pressure appliance reg- ulator.
  • Page 26: Ignition

    IGNITION MANUAL PILOT FIREBOWL TO LIGHT PILOT • Operate at arms length. • Do not lean over the appliance. • Use safety-goggles and a extended torch. Make sure gas valve control knob on appli- ance is in the OFF or CLOSED position. Turn ‘plain view’...
  • Page 27 IGNITION MANUAL PILOT FIREBOWL SUCCESSFUL IGNITION TO PUT BURNER OUT TURN ‘PLAIN VIEW’ SHUT OFF VALVE TO OFF OR CLOSED POSITION WAIT FOR GAS TO BURN OUT OF LINE TURN GAS VALVE CONTROL KNOB ON APPLI- ANCE TO OFF POSITION. ALWAYS SHUT DOWN IN THIS MANNER: GAS LINE FIRST, APPLIANCE SECOND.
  • Page 28: Rocks

    ROCKS MANUAL PILOT FIREBOWL LAVA ROCK ONLY Lava rocks are the recommended rock for use in the firebowl. Lava rock is best suited because it was made by heat and therefore does not react when used in a high heat en- vironment;...
  • Page 29: Maintenance

    MAINTENANCE MANUAL PILOT FIREBOWL MAINTENANCE Visually inspect the burner annually both while firing and while turned off. Replace any Properly maintained, your decorative gas ap- corroded parts. pliance will provide years of useful service. A regular routine maintenance program such as Visually inspect pilot while main burner is on the program outlined below should be estab- and while main burner is off.
  • Page 30 MAINTENANCE MANUAL PILOT FIREBOWL VISUAL MAINTENANCE In order to keep your fire feature function- ing properly and efficiently, a visual check of its components is necessary. The vital components to prove are the pilot burner and main burner while they are lit. Before looking at these components, re- move all lava stones and any debris from the bowl.
  • Page 31: Replacement Parts

    REPLACEMENT MANUAL PILOT FIREBOWL PARTS All parts may be ordered by calling FIRE FEATURES, a division of Colombo Construc- tion Corporation at 212-334-5069 or by emailing info@firefeatures.com. VALVE TRAIN ASSEMBLY: PILOT GUARD & SIGHTING ASSEMBLY: 1. Connecting Tube Assembly 11. Pilot Guard 2.