INSTALLATION AND OPERATING INSTRUCTIONS
Piccolo "Trend" Series Sauna Heaters
Models 1.7, 2.1, and 3.5
(Type #'s 1217-17-1706, 1217-21-1706, and 1217-35-1706)
w
ith
Trend Control
Read all instructions carefully before installation. Please leave all
instructions and warranty with the owner.
WARNING
Prolonged exposure to elevated temperatures is capable of inducing
hyperthermia. Hyperthermia occurs when the internal temperature of the
body reaches several degrees above the normal body temperature of
98.6°F. The symptoms of hyperthermia include an increase in the normal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The
effects of the hyperthermia include failure to perceive heat, failure to
recognize the need to exit the room, unawareness of impending hazard,
fetal damage in pregnant women, physical inability to exit the room and
unconsciousness.
WARNING
The use of alcohol, drugs, or medication is capable of greatly increasing
the risk of fatal hyperthermia.

SECTION 1: GENERAL INFORMATION

These heaters are ETL approved by Intertek for permanent installations and
electrical connections. Built with splash proof construction, the conducting
parts are protected against water. All wiring must be performed in
accordance with national and local codes. See Diagram 2 for wire and
room size requirements. These heaters are hung on the wall. The heater is
31" tall by 11"deep by 9 1/2" wide.
72-0111
11-10-17
(Type # 1601-31 and 1601-31-1)
WARNING
Do not take a sauna if using
alcohol, drugs or
medications.
Pregnant women or persons
with poor health should
consult their physician before
using any sauna.
Caution re hazard: Do not
use the sauna room for
drying clothes, bathing suits,
etc. Do not hang towels
above heater or place any
object other than the rocks
supplied on the heater. If any
darkening of the wall around
the heater is noticed
.
discontinue sauna use
immediately.
Inspect sauna regularly for
required maintenance to
heater, control and benches.
Replace wood surfaces
which show any signs of
deterioration.
The heater gets extremely hot
during operation and should
not be touched or burns may
Minors should be adequately
supervised whenever near a
hot or warming sauna.
Page 1
result.
7014625
314 SKMS 1 A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Trend 1.7 and is the answer not in the manual?

Questions and answers

Summary of Contents for Piccolo Trend 1.7

  • Page 1: Section 1: General Information

    Do not hang towels above heater or place any Piccolo “Trend" Series Sauna Heaters object other than the rocks supplied on the heater. If any Models 1.7, 2.1, and 3.5...
  • Page 2 Volume Power Supply to HEATER MODEL / Area Height Cu.Ft. Height Cu.Ft. Heater Product Number PHASE AMPS Piccolo Trend 1.7 7 sq. ft. 73 1/2" 84" 14.2 2 #12AWG+N+GR 1217-17-1706 Piccolo Trend 2.1 8 sq. ft. 73 1/2" 96" 17.5...
  • Page 3: Section 2: Mounting Of Sauna Heater

    INSTALLATION AND OPERATING INSTRUCTIONS Page 3 WARNING SECTION 2: MOUNTING OF SAUNA HEATER HANGING THE HEATER This heater can be installed in a corner or on a at wall. The heater brackets are factory attached for a at wall installation. To mount the Fire sprinkler systems used heater in the corner reverses the brackets.
  • Page 4 INSTALLATION AND OPERATING INSTRUCTIONS Page 4 DIAGRAM 3 DIAGRAM 4 Mounting Heater to Flat wall or Corner. Sensor protective cover. Locate top of sensor 3" from ceiling Sensor and directly above of heater. Wire Trend Control 73 1/2" Minimum ceiling spacing Heater Input Power High...
  • Page 5 INSTALLATION AND OPERATING INSTRUCTIONS Page 5 DIAGRAM 6 120 Volt Wiring Diagram Color Code Piccolo Heater Models 1217-17-1706 1.7 kW Trend / A30 Sensor 1217-21-1706 2.1 kW Control 1601-31 or 1601-31-1 Sauna Heater Left Left Element Element Right Element 120 Volt...
  • Page 6 INSTALLATION AND OPERATING INSTRUCTIONS Page 6 DIAGRAM 6 240 Volt Wiring Diagram Color Code Piccolo Heater Model Trend / A30 1217-35-1706 3.5 kW Sensor Control 1601-31 or 1601-31-1 Sauna Heater Left Left Element Element Right Element 120 Volt X4 X6...
  • Page 7: Section 6: Heater Guard Rail

    INSTALLATION AND OPERATING INSTRUCTIONS Page 7 WARNING SECTION 6: HEATER GUARD RAIL Install a wooden heater guard to prevent the sauna bather from accidentally touching the sauna heater. Install the heater guard rail with the dimensions shown Do not locate benches over in Diagram 1.
  • Page 8: Section 8: High Limit Control (Reset Button)

    INSTALLATION AND OPERATING INSTRUCTIONS Page 8 SECTION 7: OPERATION, Continued SET TEMPERATURE: Press function button (F). Then you can choose the desired temperature 1–10 using buttons < and >. (Setting 10 equals highest set point.) START HEAT IMMEDIATELY: Start the heater on by pressing the On/Off button. The latest temperature and usage time settings will remain preset.
  • Page 9 INSTALLATION AND OPERATING INSTRUCTIONS Page 9 DIAGRAM 7 DIAGRAM 8 TYPICAL PRE-CUT WALL CONSTRUCTION Electrical Compartment Components 1/2" wallboard 2x4" framing berglass insulation foil vapor barrier T&G soft wood 1/2" wallboard A. - Light Out Terminal Block B. - Trend Control Port Connection (Suggest Upper Left Port) C.
  • Page 10: Section 10: Warning Placards

    INSTALLATION AND OPERATING INSTRUCTIONS Page 10 WARNING DIAGRAM 11 The "CAUTION" and "WARNING" placards must be mounted in accordance with Section 10. BWT tank hangs on the top of the BWT tank, tank lid, and the fragrance heating elements and aligns with diffuser installed and the rocks placed inserted tabs into back heat shield.
  • Page 11: Section 12: Ventilation

    INSTALLATION AND OPERATING INSTRUCTIONS Page 11 SECTION 12: VENTILATION VENTILATION In a sauna, the air should be changed about 6 times an hour. This can be achieved by making a vent opening (fresh air inlet) in the sauna wall directly below the heater. The air outlet must be lower than the upper benches, as far as possible from the heater and about two feet higher than the fresh air inlet vent, See Diagram 9.
  • Page 12 INSTALLATION AND OPERATING INSTRUCTIONS Page 12 DIAGRAM 12: ROOM TEMPERATURES 190° F Ceiling Non-Typical Ceiling Height 140° F Head Height Notes: Temperatures vary in a sauna room by height and distance from heater. Ventilation will help reduce it but will not eliminate temperature variations.
  • Page 13: Section 15: Replacement Parts

    INSTALLATION AND OPERATING INSTRUCTIONS Page 13 SECTION 15: REPLACEMENT PARTS 72-0111 11-10-17 7014625 314 SKMS 1 A...
  • Page 14 INSTALLATION AND OPERATING INSTRUCTIONS Page 14 SECTION 15: REPLACEMENT PARTS ID # THI Part Number Description 3001-761 Element,850W, 120V, SEPC-232 3001-762 Element, 1050W, 120V, SEPC-233 3001-763 Element, 1750W,240V,SEPC-234 8100-479 BWT Tank 4009-001 BWT Tank Cover 8221-06 BWT Herb cup 8100-485 Heater wall mount bracket 8012-524 Shroud, outer, black...
  • Page 15: Section 16: Troubleshooting

    INSTALLATION AND OPERATING INSTRUCTIONS Page 15 SECTION 16: TROUBLESHOOTING Control will Run but No Heat - Press the (reset) high limit switch on the back right side of heater. Slow Heat Time or High Limit Tripping - Check rock placement, they will break down over time and reduce the air ow in the heater.

This manual is also suitable for:

Trend 2.1Trend 3.5

Table of Contents