DigitaLinx IPEXCB Quick Install Manual

Scan qr code with smart-phone or tablet

Advertisement

Quick Links

IPEXCB Quick Install Guide
For complete Digitalinx IP Deployment Guide go to www.libav.com or use a
QR reader to access the manual via QR code below.
Important notice:
• Do not attempt to disassemble or alter the housing. There are no user-serviceable parts
inside the unit. Doing so will void your warranty.
• To minimize the possibility of equipment damage from electrostatic discharge (ESD), all source and destination
equipment must be powered off during installation.
• Do not connect the device to a telecommunication outlet wired to unrelated equipment. Doing so may
damage the unit or any connected equipment. Ensure all connected twisted pair cabling is straight-through (point-
to-point).
• Allow proper ventilation to reduce the risk of thermal failure.
This guide is for quick installation only.
Scan QR Code with your Smart-phone or Tablet

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPEXCB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DigitaLinx IPEXCB

  • Page 1 IPEXCB Quick Install Guide This guide is for quick installation only. For complete Digitalinx IP Deployment Guide go to www.libav.com or use a QR reader to access the manual via QR code below. Scan QR Code with your Smart-phone or Tablet Important notice: •...
  • Page 3: Product Overview

    IP addresses and subnets for the two IPEXCB LAN ports, the A/V LAN traffic is not forced to reside on a shared LAN that may compromise bandwidth and data flow. The RS232 ports on the IPEXCB are also designed to offer a single point of control for serial based control systems.
  • Page 4: Front And Rear Panels

    Front and Rear Panels Front Panel RESET STATUS POWER Label insert Reset button Status indicator Power indicator Rear Panel DC 12V DEBUG LAN1 LAN2 RS232 (AV/PoE) (CTRL) A. LAN1 (AV/PoE) B. LAN2 (CTRL) C. RS232 connections D. 12V DC power input...
  • Page 5 Reset Button If a factory reset is required for the IPEXCB, press and hold the reset button for five seconds to restore the IPEXCB to factory settings. This reset will change the default IP address of the IPEXCB back to the factory default IP address.
  • Page 6: Basic Installation

    Apply power to the attached audio/video devices. To control the IPEXCB and Digitalinx IP devices by a third party IP control system, connect a Category cable between the LAN2 port on the IPEXCB to an IP based third party control system network.
  • Page 7 Connect a Windows PC to an open port on the configured A/V network switch with a Cat 5e patch cable and set a static IP address for the Windows PC that is within the IP range of the DigitalinxIP IPEXCB Controller (169.254.1.xxx, where xxx = any number between 2-254) and set the subnet mask to 255.255.0.0.
  • Page 8 A pop window will appear labeled Ethernet Properties Select Internet Protocol Version 4 (TCP/IPv4) from the item list and then click A pop window will appear labeled Internet Protocol Version 4 (TCP/IPv4) Properties Select the button labeled...
  • Page 9 Enter in an IP address for the computer in the same range as the IPEXCB in the IP Address field, set the subnet mask to 255.255.0.0 and click In this example we used the IP address of 169.254.1.99 with a subnet mask set at 255.255.0.0...
  • Page 10 CONTROLLER SETTINGS; allows you to change the default IP addresses of the LAN1 (AV/ PoE) and LAN2 (CTRL) ports of the IPEXCB. You can also load system configurations, setup security access, change passwords for admin login, establish user name and password for...
  • Page 11 Routing Video Signals Using the web GUI, video signals can be routed from DigitalinxIP encoders (TX) to decoders (RX) using the SCENES menu. When the SCENES menu is highlighted, click on ALL DEVICES, this will show all of the active DigitalinxIP encoders and decoders on the A/V network switch as well as four submenus labeled MATRIX, SCENE1, SCENE2, and SCENE3.
  • Page 12 The MATRIX submenu allows you to route video signals from encoders to decoders in real time using a simple spread sheet layout. Encoders (transmitters) are labeled as TX and located on the top row, decoders (receivers) are labeled as RX and located to far left column. Simply use your mouse and click on the appropriate cell that links the desired TX source to the desired RX location.
  • Page 13 An API command log is also available to monitor system responses which can be turned ON or OFF. If you want a comprehensive list of telnet and serial commands please refer to the DigitalinxIP Programming Guide which can be downloaded from the IPEXCB product page under the DOCUMENTATION tab online at www.libav.com To test a command enter the command into the blank form under Telnet API Command and click Apply.
  • Page 14 The DigitalinxIP IPEXCB control interface automatically assigns IP addresses to encoders and decoders in an DigitalinxIP system when they are discovered by the IPEXCB. You can change these auto assigned IP addresses to an address scheme of your choice by accessing the TX/RX SETTINGS menu.
  • Page 15 Changing IPEXCB IP Addresses The DigitalinxIP IPEXCB control interface is assigned with two default IP addresses; one for encoder (TX) / decoder (RX) communication and one for telnet client / browser communication. To access the IP information for the IPEXCB click on the CONTROLLER SETTINGS menu tab.
  • Page 16 Loading DigitalinxIP Configurator Files Configuration files that have been built with DigitalinxIP Configurator can be uploaded to the DigitalinxIP system by using Load Configuration option under CONTROLLER SETTINGS menu. To load a configuration file, select BROWSE to locate the file located on your computer or hard disk. Click APPLY to initialize.
  • Page 17 To establish a password for Telnet communication, enter the password in the Telnet field and click Save. To enable SSH service for the IPEXCB, check the enable box in the SSH Service section and click Apply. To disable SSH service for the IPEXCB, check the disable box in the SSH Service section and click...
  • Page 18: Technical Specifications

    Technical Specifications Input/Output Connections Two (2) 8P8C port (Shielded RJ45) Power One (1) 5.5 mm OD, 2.6 mm ID Threaded Barrel RS232 Port One (1) 6-pin Removable Terminal Block Connector Reset Button One (1) Recessed Microswitch Supported Control Supported Baud Rates 9600 (control) and 115200 (debug) Ethernet 100BaseT...
  • Page 20 Thank you for your purchase. For Technical Support please call our toll free number at 800-530-8898 or email us at supportlibav@libav.com www.intelix.com www.libav.com Digitalinx IP is a brand of: 11675 Ridgeline Drive Colorado Springs, Colorado 80921 USA Phone: 719-260-0061 Fax: 719-260-0075...