Installation Guide
1
Components:
1. General LED PS12-180W-3-A Power Supply
2. Minimum 18 AWG (0.82mm) Wire - (UL Approved)
*Under certian conditions, a heavier guage wire may be neccesary.
3. PLTC Cable - UL Listed
4. 22 - 14 ASG (0.33 - 2.08mm) wire connectors or 22 - 18 AWG
(0.33 - 0.82mm) wire nuts, IDC connectors or butt splice
connectors, cable ties - UL Approved
5. #6 or #8 (M3 or M4) screws
AC INPUT (3*AWG #18)
DC OUTPUT (2*AWG #18)
1. AC Input wires: Black = Line
White = Neutral, Green = Ground
DC Output wires:
Black = Negative (-),
Red = Positive (+)
Notes:
• Intended to be installed in another device, system or end product,
subject to Conditions of Acceptability of the UL SAM Manual.
• UL 48 Standard requires that the spacing between transformers,
ballasts, neon power supplies and LED power supplies shall be at
least 1 inch (25.4 mm) from end to end and 4 inches (101.6 mm)
from side to side.
• When connecting power supply to 277 VAC, make sure the input
voltage is correct and not 480 VAC.
• Use the proper gauge wire for connecting power supply to product.
• Do not overload the power supply. If the power supply is overloaded,
cycle input power to restart power supply.
• The grounding and bonding of the LED Driver must be done in
accordance with ordnance National Electric Code (NEC) Article 600.
• Follow all National Electric Codes (NEC) and local codes.
General LED Power Supply
• The maximum case temperature shall not exceed 75ºC (167°F) when used in end product.
• These products are intended to be connected to a max. 20 A branch circuit.
• These products are intended for use in dry, damp and wet locations.
AgiLight, Inc., a Division of General LED Opco, LLC. +1.866.482.0203
1074 Arion Cirlce, Suite 116, San Antonio, TX 78216
PS12-180W-3-A
Power Supply
2
3
5
4
Mounting Tabs
2. For mounting purposes, several
mounting tabs have been placed
on the power supply end caps to
allow for flexibility in mounting
locations and positions.
www.AgiLight.com
Mounting Tabs
3. Connect the power supply to the
product as outlined in the
SignRayz
Series Installation Guide.
Jumper Wire Gauge Chart
Wire Gauge (AWG)
18
16
14
12
10
*Distance from power supply to first LED module of the string
(at full capacity)
© 2017 General LED Opco, LLC. 2017 All rights reserved.
Product Specifications subject to change without notice. 10-2017
1
2
3
4
5
Tools:
1. Wire Stippers
2. Screw Driver
3. Adjustable Wrench
4. Tape Measure
5. Drill
/ SignRayz
PRO
®
®
MAXIMUM DISTANCE*
STANDARD (ft)
METRIC (m)
18
5.5
29
8.8
45
13.7
71
21.6
120
36.6
WARNING
RISK OF ELECTRICAL SHOCK
Turn OFF power before
perfoming any maintenance.
Need help?