Fairford AGY-020 Installation Manual

Advertisement

Power Supply (AGY-020)

AGY-020 is a dedicated mains power supply for the agility soft start. In addition to allowing for mains
control voltage operation, the power supply also allows for mains voltage digital control (D1/D2).

Fitting

Ensure terminals 24V, 0V, COM, D1 and D2 are fully open before installing power supply as
shown below:
Tighten terminals 24V, 0V, COM, D1 and D2
When the AGY-020 installation is complete, control supply, D1 and D2 are provided on the
power supply rather than the agility main unit
AGY-020 Installation Guide
MAN-AGY-003
Fit screw and nylon washer
(supplied). DO NOT overtighten
(Max 40 cNm)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGY-020 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fairford AGY-020

  • Page 1 Power Supply (AGY-020) AGY-020 is a dedicated mains power supply for the agility soft start. In addition to allowing for mains control voltage operation, the power supply also allows for mains voltage digital control (D1/D2). Fitting Ensure terminals 24V, 0V, COM, D1 and D2 are fully open before installing power supply as shown below: ...
  • Page 2 Top of Ramp Relay #1 110Vac or 230Vac, 47 – 63Hz #2 The voltage applied to the digital inputs D1 and D2 must be the same as the supply voltage. #3 230Vac, 1A, AC15. 30Vdc, 0.5A resistive AGY-020 Installation Guide MAN-AGY-003...
  • Page 3 3-Wire Control Using AGY-020 110/230Vac Start Stop 110/230Vac 2-Wire Control Using AGY-020 110/230Vac Start / Stop 110/230Vac AGY-020 Installation Guide MAN-AGY-003...