  • Page 1 ™ NetworX Series NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup...
  • Page 3: Table Of Contents

    NX-507E / NX-508E AUXILIARY MODULES TABLE OF CONTENTS GENERAL DESCRIPTION ....................4 WIRING INFORMATION ....................4 III. NX-507E TERMINAL DESCRIPTION ................5 NX-507E DRAWING....................... 6 NX-508E TERMINAL DESCRIPTION ................7 NX-508E DRAWING....................... 7 VII. INSTALLING THE MODULES ..................8 VIII.
  • Page 4: General Description

    NX-507E / NX-508E AUXILIARY MODULES GENERAL DESCRIPTION The NetworX NX-507E and NX-508E are auxiliary modules used to expand the capabilities of the NetworX control panels. While each unit has some unique features described in this section and also in the terminal descriptions, the basic installation and programming instructions are applicable to both modules.
  • Page 5: Nx-507E Terminal Description

    Connect to the control panel COMMON terminal. This terminal supplies the common side of the power to the NX-507E board. Connect to control panel AUX POWER + terminal. This terminal supplies power to the NX-507E board. This is an option tamper terminal. To use this feature, connect the normally closed tamper switch between this terminal and COM.
  • Page 6: Nx-507E Drawing

    NX-507E / NX-508E AUXILIARY MODULES NX-507E DRAWING All outputs are Class 2, power limited.
  • Page 7: Nx-508E Terminal Description

    Any power drain from this terminal should be included in total current draw from the NetworX control panel or NX-320E as applicable. This allows an isolation of the power between the main control and remote devices. If a short is created past the AUX terminal, those devices will cease to function, but the other devices, including the NX- 508E, will continue to operate.
  • Page 8: Installing The Modules

    ENROLLING THE MODULES VIII. The NetworX control panels have the ability to automatically find and store in memory the presence of all keypads, zone expanders, wireless receivers, output modules, and any other device on the keypad buss. This allows these devices to be supervised by the control panel. To enroll the devices, enter the Program Mode using the procedure outlined in the control panel Installation Manual.
  • Page 9: Programming Locations

    NX-507E / NX-508E AUXILIARY MODULES PROGRAMMING LOCATIONS Location 0 Programming the Event, Zone and Time for Output 1 (3 segments of numerical data) Location 0 is used to select the particular function, zone number, and time for an output to trip.
  • Page 10 NX-507E / NX-508E AUXILIARY MODULES Segment 2 Selects the following partitions: LED 1 - "On" if the event should activate when it occurs in Partition 1. LED 2 - "On" if the event should activate when it occurs in Partition 2.
  • Page 11 NX-507E / NX-508E AUXILIARY MODULES Location 33 Programming the Closing Time for Schedule 1 (2 segments of numerical data) Segment 1 Program the hour of the closing time in 24-hour format. (1:00 PM = 13) Segment 2 Program the minutes after the hour of the closing time for Schedule 1.
  • Page 12 NX-507E / NX-508E AUXILIARY MODULES Location 74 Authorizing Users 61-70 Segment 1 corresponds to user 61; Segment 10 corresponds to user 70. Location 75 Authorizing Users 71-80 Segment 1 corresponds to user 71; Segment 10 corresponds to user 80. Location 76 Authorizing Users 81-90 Segment 1 corresponds to user 81;...
  • Page 13: Programming Examples

    NX-507E / NX-508E AUXILIARY MODULES PROGRAMMING EXAMPLES Possible application for NX-508E outputs: • Example #1 Turn on entryway light upon entry only during nighttime. • Example #2 Turn a device on or off during business hours. • Example #3 Arm the system. NOTE TO EXAMPLE #3: The opening time is defaulted to 0800 for all schedules.
  • Page 14: Programming Worksheets

    NX-507E / NX-508E AUXILIARY MODULES PROGRAMMING WORKSHEETS XII. (Defaults are printed in bold Italics text.) DESCRIPTION DEFAULT DATA Output 1 Event, Zone, Time _ _ _ 43 1 10 Output 1 Special Functions, Partition Segment 1 Segment 2 1 = "On" if output should time in minutes; "Off" if output...
  • Page 15 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION DEFAULT DATA Output 2 Schedule 1 = Schedule 1 5 = Schedule 5 2 = Schedule 2 6 = Schedule 6 3 = Schedule 3 7 = Schedule 7 4 = Schedule 4 8 = Schedule 8...
  • Page 16 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION DEFAULT DATA 1 = "On" if output should time in minutes; "Off" if output 1 = Partition 1 times in seconds 2 = Partition 2 2 = "On" if output should latch until a code is entered 3 = Partition 3 3 = "On"...
  • Page 17 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION DEFAULT DATA Segment 1 Segment 2 1 = "On" if output should time in minutes; "Off" if output 1 = Partition 1 times in seconds 2 = Partition 2 2 = "On" if output should latch until a code is entered 3 = Partition 3 3 = "On"...
  • Page 18 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION DEFAULT DATA Output 8 Special Functions, Partition Segment 1 Segment 2 1 = "On" if output should time in minutes; "Off" if output 1 = Partition 1 times in seconds 2 = Partition 2 2 = "On"...
  • Page 19 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION DEFAULT DATA Schedule 4 Opening Time 8 - 0 Schedule 4 Closing Time 20 - 0 Schedule 4 Days (Circle the numbers to program) 1 = Sunday 5 = Thursday 2 = Monday 6 = Friday...
  • Page 20 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION DEFAULT DATA August Holidays 0-0-0-0-0-0-0-0 _ _ _ _ _ _ _ _ September Holidays 0-0-0-0-0-0-0-0 _ _ _ _ _ _ _ _ October Holidays 0-0-0-0-0-0-0-0 _ _ _ _ _ _ _ _...
  • Page 21 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION Output #1 Output #2 Output #3 Output #4 Output #5 Output #6 Output #7 Output #8 CODES 51-60 OUTPUT SELECTION (Circle the numbers to program) User Output #1 Output #2 Output #3 Output #4...
  • Page 22 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION Output #1 Output #2 Output #3 Output #4 Output #5 Output #6 Output #7 Output #8 CODES 101-110 OUTPUT SELECTION (Circle the numbers to program) User Output #1 Output #2 Output #3 Output #4...
  • Page 23 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION Output #1 Output #2 Output #3 Output #4 Output #5 Output #6 Output #7 Output #8 CODES 151-160 OUTPUT SELECTION (Circle the numbers to program) User Output #1 Output #2 Output #3 Output #4...
  • Page 24 NX-507E / NX-508E AUXILIARY MODULES DESCRIPTION Output #1 Output #2 Output #3 Output #4 Output #5 Output #6 Output #7 Output #8 CODES 201-210 OUTPUT SELECTION (Circle the numbers to program) User Output #1 Output #2 Output #3 Output #4...
  • Page 25: Enclosure Diagram

    NX-507E / NX-508E AUXILIARY MODULES ENCLOSURE DIAGRAM XIII. Inside the can, several 2-holed insertion points have been constructed. This allows for either vertical or horizontal placement of the modules. Notice that the insertion points have two sizes of holes -- a larger hole and a smaller hole.
  • Page 26: Specifications

    12 VDC, Supplied from NX control panel or NX-320E AUXILIARY POWER Supplied by NX control panel or NX-320E Limited to 100 mA by NX-507E or NX-508E NX-507E CURRENT DRAW 10 mA with no relays active 310 mA with all relays active...