Summary of Contents for Coretec Trainer 1000

  • Page 1 User Manual V 2.1 GBR...
  • Page 2 At the same time, the Trainer 1000 can be used to simulate changes experienced trainees. At the same time, the Trainer 1000 can be used to simulate changes in a patient’s state by using the AED Trainer’s IR remote control and intervene if the Trainer is used incorrectly.
  • Page 3: Table Of Contents

    PAGE 3 OF 37 CONTENTS Trainer 1000 AED Training System Quick Start Guide ...................... 5 Defibrillation ..................................7 Operating Modes ................................8 Safety instructions ................................9 Symbols ..................................11 Operating elements, controls and connections......................13 Preparing the Trainer 1000 for use..........................16 Unpacking and checking components ........................
  • Page 4 PAGE 4 OF 37 USER MANUAL Maintenance ..............................................30 Cleaning and maintaining the ..........................30 Battery................................................. 30 Disposal............................................... 30 Potential errors and remedies ........................................31 Order ................................................33 Models ................................
  • Page 5: Trainer 1000 Aed Training System Quick Start Guide

    INFORMATION ON USING THE TRAINER 1000 FOR TRAINING PURPOSES The Trainer 1000 is designed only for training people in the use a defibrillator on adults and children over the age of 8, weighing more than 25 kg, and using standard training electrodes (black connector).
  • Page 6 This button is disabled. Intended only for use on Trainers with ECG mode. PAUSE. Can be pressed at any time to stop any PAUSE. Can be pressed at any time to stop any of the Trainer 1000’s functions. Press again to of the Trainer 1000’s functions. Press again to resume operation.
  • Page 7: Defibrillation

    Coretec-Service is a training and simulation device for the work performed with an automated external defibrillator (AED). The Trainer 1000 is not capable of detecting cardiac arrhythmias or of delivering a defibrillation shock, but is a training device only that allows potential users to be trained in the use of a defibrillator by simulating corresponding sounds and visual indicators.
  • Page 8: Operating Modes

    The readout provided on the screen represents the consolidated data from lead II. The Trainer 1000 does not issue any spoken instructions in this mode. If the CPPS (Continuous Patient lead II. The Trainer 1000 does not issue any spoken instructions in this mode. If the CPPS (Continuous Patient lead II.
  • Page 9: Safety Instructions

    Trainer 1000’s performance. Do not use any of the ’s accessories with fully operational defibrillators that are used to treat patients and vice a verse. The Trainer 1000 must only be used with the components and accessories specified in this user manual.
  • Page 10 The Trainer 1000 must only be used with the accessories specified in this user manual. Only use the original charger with the original cable supplied with the Trainer 1000 for connecting it to the mains. er with the original cable supplied with the Trainer 1000 for connecting it to the mains.
  • Page 11: Symbols

    Read the user manual Read the user manual Read this user manual before using the Trainer Read this user manual before using the Trainer 1000 for the first time. Observe the safety instructions. Observe the safety instructions. Do not dispose of as household waste...
  • Page 12 PAGE 12 OF 37 USER MANUAL Fragile! Do not throw! Fragile! Do not throw! Handle with care Protect from moisture Protect from moisture Do not store in a wet or damp location and protect from moisture during transport store in a wet or damp location and protect from moisture during transport store in a wet or damp location and protect from moisture during transport This side up!
  • Page 13: Operating Elements, Controls And Connections

    Issues voice prompts and audio signals. ON / OFF button The green ON/OFF button turns the power supply on and off. The green LED above this button will always light up when the Trainer 1000 is turned on. PHONE: +49-6403-60984-0 FAX: +49-6403-60984-44 E-MAIL: INFO@CORETEC-SERVICE.COM...
  • Page 14 PAGE 14 OF 37 USER MANUAL SHOCK button Pressing this red button will cause the device to simulate a delivery of a Pressing this red button will cause the device to simulate a delivery of a Pressing this red button will cause the device to simulate a delivery of a shock to the patient shock to the patient (when flashing).
  • Page 15 Battery status symbol The battery status symbol on the screen indicates the relative charge held by the battery when the Trainer 1000 is turned on, and can be adjusted through the remote control. This symbol can be displayed in two ways: 1. With four solid bars inside it, indicating that the battery is fully charged.
  • Page 16: Preparing The Trainer 1000 For Use

    When switched off, the Trainer 1000 will fully recharge within approx. 2.5 hours (using the European charger). The Trainer 1000’s battery can also be charged while it is switched on, although it will then take longer to charge. The Trainer 1000’s battery can also be charged while it is switched on, although it will then take longer to charge.
  • Page 17: Starting A Training Session

    Check the AED Trainer settings and configure as required. Please refer to the relevant sections of this manual for detailed information on the setup options and configurations. Connecting the training electrodes to the Trainer 1000 Push the electrode connector into the relevant socket on the AED Trainer until it engages.
  • Page 18: Attaching The Training Electrodes To The Mannequin

    Never use defibrillator electrodes intended for use on patients. The Trainer 1000 will not reco Never use defibrillator electrodes intended for use on patients. The Trainer 1000 will not recognise these electrodes and they could damage the outer skin of the mannequin or leave behind stubborn residues.
  • Page 19: Using The Remote Control

    Connect the other end of the cable to the corresponding socket on the AED Trainer’s side. To remove, take hold of the cable’s connectors on both sides and pull out carefully. PHONE: +49-6403-60984-0 FAX: +49-6403-60984-44 E-MAIL: INFO@CORETEC-SERVICE.COM HOMEPAGE: WWW.TRAINER1000.COM...
  • Page 20 This button is disabled. Intended only for use on Trainers with ECG mode. PAUSE. Can be pressed at any time to stop any of PAUSE. Can be pressed at any time to stop any of the Trainer 1000’s functions. Press again to the Trainer 1000’s functions. Press again to resume operation.
  • Page 21: Setup Mode

    The screen will now display the configuration menu (set up mode). The Trainer 1000’s setup mode is not password protected, as this is not relevant to a training device. You will now be presented with 4 different menus in which to adjust the Trainer 1000’s settings to suit your requirements: GENERAL This menu can be used to configure the audio settings.
  • Page 22: General Settings

    Prompt volume This option can be used to set Volume: High, Medium, up the audio signals issued by Audio the Trainer 1000, and to select one of 3 volume settings. Shock Tone Depending on the area of Shock Tone: On, Off...
  • Page 23: Aed Mode Settings

    Voice prompt: Check Pulse, pulse checking. Check Breathing, Check vital signs, Open Airway AED Monitoring For using the CPPS AED monitoring: On, Off (Continuous Patient Surveillance System) to monitor the patient for shockable heart rhythms. PHONE: +49-6403-60984-0 FAX: +49-6403-60984-44 E-MAIL: INFO@CORETEC-SERVICE.COM HOMEPAGE: WWW.TRAINER1000.COM...
  • Page 24: Manual Mode Settings

    PAGE 24 OF 37 USER MANUAL Monitoring Repeat Monitoring Repeat For specifying the frequency Monitoring: Monitoring: Off, 1 min, 2 min, with which the CPPS 3 min, 5 min 3 min, 5 min (Continuous Patient Surveillance System) is to monitor the patient for shockable heart rhythms.
  • Page 25: Trainer Settings Menu

    Fix 3 (SSNNNN) to devise a realistic Fix 4 (SSNSSN) training scenario. Fix 5 (SNNN) (see Quick Start Guide). Customer (freely configurable) (S: shock, N: No Shock Advised) PHONE: +49-6403-60984-0 FAX: +49-6403-60984-44 E-MAIL: INFO@CORETEC-SERVICE.COM HOMEPAGE: WWW.TRAINER1000.COM...
  • Page 26: Setting Options: Cprmax Menu

    PAGE 26 OF 37 USER MANUAL Setting options: CPRmax menu Setting options: CPRmax menu The cprMAX technology has the following setup options: The cprMAX technology has the following setup options: Initial CPR time. Only applies to the first analysis. Prompts for CPR Only applies to the first analysis.
  • Page 27 If the rhythm has changed, the confirmation analysis will cancel the shock and the AED will prompt NO SHOCK ADVISED. If the rhythm is still shockable, the previous decision of SHOCK ADVISED will be confirmed and the AED will prompt to PUSH SHOCK BUTTON. PHONE: +49-6403-60984-0 FAX: +49-6403-60984-44 E-MAIL: INFO@CORETEC-SERVICE.COM HOMEPAGE: WWW.TRAINER1000.COM...
  • Page 28: Configuring The Energy Protocol

    Press SELECT to save the required energy setting when it comes up and move to the next setup screen or press ON/OFF to close the setup menu and to turn off the Trainer 1000 with the new settings. ON/OFF to close the setup menu and to turn off the Trainer 1000 with the new settings.
  • Page 29: Turning Auto Analyse On/Off

    Auto Analyse is a function that enables the input required from users to be reduced to a minimum. When this function is enabled, the Trainer 1000 will automatically start an ECG analysis as soon as the adhesive electrodes have been attached to the patient. This minimises the chances of the AED being used incorrectly when operated by laypersons.
  • Page 30: Maintenance

    Recycle the packaging and the Trainer 1000, when it ha Recycle the packaging and the Trainer 1000, when it has reached the end of its life, in accordance with the local s reached the end of its life, in accordance with the local regulations and laws.
  • Page 31: Potential Errors And Remedies

    Trainer contains a fuse and whether the fuse is properly screwed in. Once you have finished, start the Trainer 1000. The fuse is broken Replace the fuse using only G fuse packs 1.25 A/250 V, slow blow DIN 415671 as replacements and then start the Trainer 1000.
  • Page 32 If none of the above remedies work, the Trainer 1000 might have a fault. In this case, please contact the If none of the above remedies work, the Trainer 1000 might have a fault. In this case, please contact the If none of the above remedies work, the Trainer 1000 might have a fault.
  • Page 33: Order

    Russian, Slovenian When placing an order, please also specify: -The required bag (soft or hard bag). If no bag is specified, the Trainer 1000 is supplied with a soft bag. -The required charger (please see under accessories for available models) Please note: The Trainer 1000 is always supplied with an AED and a manual mode by default.
  • Page 34: Accessories

    ECG remote control – Trainer 1000Trainer Trainer 1000Trainer 1007007 batteries. 1000 3-pin ECG cable for use with a Trainer 1000 with pin ECG cable for use with a Trainer 1000 with 1008006 ECG cable – Trainer 1000 Trainer 1000 ECG mode.
  • Page 35: Certification And Technical Data

    Software versions Trainer 1000 Lifepak 1000 Properties SW – V 1.0x LIFEPAK 1000 Software status while the Trainer 1000 was developed The software version is shown under Device Data in the setup menu in the Trainer SW - V 1.10 2.2x...
  • Page 36 PAGE 36 OF 37 USER MANUAL...
  • Page 37 • ECG Display (if option set in setup menu) DEFIBRILLATOR: DISPLAY DISPLAY The Trainer 1000 has the operation extent – Turns display on/off for AED mode Backlit LCD displays number of shocks Backlit LCD displays number of shocks and menu navigation of the LIFEPAK® 1000, •...