Crow Power Wave 16 Alarm Panel
 Panel Dialler wiring
 Panel Dialler programming
Background:
The PM45 & PM1048-3G (v3) communicator now has a terminal block for the connection of the female 611 fly lead (supplied).
If the Alarm Panel also has a terminal block for PSTN connection, we recommend you use your own cable between the Alarm
Panel dialler and PM45 & PM1048-3G (v3).
This type of installation negates the use of the female 611 fly lead, decreasing your installation time.
For four (4), six (6) and eight (8) pin RJ connectors, please refer to manufactures wiring diagram.
There are four minimum requirements from the Alarm panel for successful communication:
1) Must have an eight (8) digit primary phone. E.g. 12345678 or 55555555.
2) A four (4) digit account number.
3) Must be Contact ID format.
4) Must be set for tone (DTMF) dialling.
5) Optional is open / close reporting, must be enabled for Pocket Secure App.
Dialler Lead wiring between Permaconn and Crow Power Wave 16 Alarm Panel:
Permaconn
R
1
R
T
T
1
Crow Power Wave 16 Alarm Dialler wiring & programming
Crow Power Wave 16
black
red
green
yellow
red
green
black
yellow
RDC_3026_E_TA
Panel
Tip - IN
Ring - IN
Tip - OUT
Ring - OUT
Page 1

Advertisement

loading

Summary of Contents for Permaconn Crow Power Wave 16

  • Page 1 3) Must be Contact ID format. 4) Must be set for tone (DTMF) dialling. 5) Optional is open / close reporting, must be enabled for Pocket Secure App. Dialler Lead wiring between Permaconn and Crow Power Wave 16 Alarm Panel: Crow Power Wave 16 Permaconn...
  • Page 2 Programming the Crow Power Wave 16 Alarm Panel for dialler operation: Description Location Default Dialler Options Option 1 = Dialler On On = Yes, Off = No dialler (default) Option 2 = DTMF (On) or Pulse (Off) On = Yes(default), Off = Pulse...