1.0 Specifications
• Input Power: 6 to 15 VDC; 18 mA-H @ 12 VDC.
• Standby Power: There is no internal standby battery. Connect to
DC power sources capable of supplying standby power if primary
power fails. Eighteen mA-H required for each hour of standby
time needed. Four hours (92 mA-H) minimum are required for
Underwriters Laboratories' Certificated installations.
• Coverage:
Standard Broad
50 ft. by 50 ft.
Barrier (Optional)
80 ft. by 16 ft.
Long Range (Optional)
120 ft. by 10 ft.
• Sensitivity: Adjustable for Standard, Intermediate, or High.
• Alarm Relay: Form "C" reed relay with contacts rated at 3 watts,
28 VDC, 125 mA maximum for DC resistive loads.
• Tamper Switch: Normally Closed (with cover in place) tamper
switch. Contacts rated at 3 watts, 28 VDC, 125 mA maximum.
• Temperature: The storage and operating range is -40° to +120°F
(-40° to +49°C). For U. L. Certificated installations, the range is
+32 ° to +120 ° F (0 ° to +49 ° C).
• Options: TC6000 Test Cord, B328 Gimbal Mount Bracket,
B335-3* Low Profile Swivel Mount Bracket, OMB77-3* Barrier
Mirror, and the OMLR77-3* Long Range Mirror. *Shipped in
packages of three.
Note:
Misalignment of the detector when using an optional
mounting bracket may reduce range.
• U. S. Patent Numbers: # 4,764,755 and # 5,083,106.
2.0 Mounting
Chassis
Screw
T-Strip
1 2 3
OFF
Noise
Configuration
Voltage
Switches
LED
Tamper Switch
Location of Major Items
Circuit Board
Things to Avoid/Remember
Direct hot and/or cold drafts. Windows. Small animals.
Air conditioning outlets. Heat sources. Direct sunlight.
Remember
Won't detect through glass. Best catch performance
is across the pattern. When using two or more
detectors, cross patterns for best coverage.
P/N 31365B
(15.3 m by 15.3 m)
(24.4 m by 4.9 m)
(36.6 m by 3.1 m)
Wire
Knockouts
Corner
Mounting
Holes (4)
Bracket Mounting
Hole
Surface Mounting Holes
or Single Gang Box Holes (2)
Rear Enclosure
and Mounting Holes
Avoid
D9550 Installation Instructions
Installation Instructions
D9550 Passive Infrared
Intrusion Detector
• Select a location that is most likely to intercept an intruder moving
across the coverage pattern.
• The recommended mounting height range is 6.5 ft. to 8.5 ft. (2 m
to 2.6 m).
Note: The mounting surface should be solid and vibration free.
• Remove the cover. Insert a thin flathead screwdriver into the
notch at the bottom of the cover and pry up.
• Remove the circuit board/mirror unit from the enclosure. Push the
circuit board/mirror unit toward the top of the enclosure until it
clears its four retainer tabs, then lift out.
• Open the knock-out wire entrance and route the wiring through.
Surface or Corner Mounting
• Open 2 holes for surface or corner mounting.
• Mark the location for the mounting screws using the enclosure as
a template.
• Pre-start the mounting screws.
• Firmly mount the detector.
• Replace the circuit board/mirror unit.
Select the Vertical Angle
The angle adjust markings are on the mirror. Slide the mirror forward
or back until the angle hash marks are in-line with the markers on
each side of the frame.
This chart will help you set the correct Vertical Angle based on the
mounting height, mirror type, and desired range.
Mounting
Height
30(9) 50(15) 50(15) 80(25) 80(25)
6.5(2)
-6°
7.5(2.3)
-8°
8.5(2.6)
-9°
Height and desired Range listed in feet (meters)
The mirror is adjustable +2° to -18° vertically and +10° to -10°
horizontally. To change the mirror, just pull it out from its resting
grooves.
Note: Excessive handling of the mirror surfaces may lead to
performance degradation.
3.0 Wiring
CAUTION: Only apply power after all
connections have been
made and inspected.
• Connect wiring as shown.
Page 1
+2
0
-8
-16
Mirror
Broad
Barrier
Long Range
120(36)
-3°
-3°
-2°
-2°
-1°
-5°
-5°
-3°
-3°
-2°
-6°
-6°
-4°
-4°
-2°
1
2
3
4
-
+
A
© 1996 Radionics
5
6
7
T

Advertisement

loading

Summary of Contents for Radionics D9550

  • Page 1 Installation Instructions Radionics ™ D9550 Passive Infrared Intrusion Detector 1.0 Specifications • Select a location that is most likely to intercept an intruder moving across the coverage pattern. • Input Power: 6 to 15 VDC; 18 mA-H @ 12 VDC.
  • Page 2 • The base reference level for reading background noise is approximately 2.0 VDC. TC6000 © 1996 Radionics, Inc., Salinas, CA, U.S.A. All rights reserved. ™ The Radionics logo is a registered trademark of Radionics, Inc., Salinas, CA, U.S.A. Radionics ™ Radionics, Inc., 1800 Abbott Street Salinas, CA, 93901, U.S.A.