Exit motion sensor Instruction

Product Description

The EMS-100 is designed for use on request-to-exit applications with maglocks and electric strikes. This sensor is not an automatic door
activation sensor. It is a request to exit sensor used to release a lock.The unit is a passive infrared detector that uses digital signature
analysis for activation. The EMS-100 is not recommended for activation on pedestrian automatic doors because the passive infrared
technology recognizes temperature changes (i.e. body temperature) for detection. As such, the EMS-100 will not recognize motion
associated with inanimate objects such as hospital beds, gurneys, shopping carts, etc.
The key advantages of the EMS-100 are fast detection, adjustable sensing fields, and no false detection from inanimate objects.
Component ID

Technical Specifications

Description
Technology
Mounting Height - Variable
Mounting Angles
Power Supply
Current Consumption
Contact Rating (Output Relay)
Optical Characteristics
Warm-up Time
Response Time
Relay Hold Time
Operating Temperature
Immunity
Cable
Weight
Dimensions:
Sensor
Housing Color
SENSOR AND
HOUSING
Lens
Sensing Field
Adjustment
Specification
Passive infrared with microprocessor
10'-0" max. (Recommended 6'-6" to 8'-0" )
0 to 180°
12-24 VAC –10/+10% (50/60Hz)
12-24 VDC –10/+30%
<10 mA (20mA if the relay output is activated)
1 A/ 75 VDC or 50 VAC Potential free contact NO/NC
Passive infrared with four elements
15 Fresnel lenses with full independent masking possibilities
10 seconds
Max 200 microseconds
0.5 or 2 seconds
-22°F to +140°F (-30°C to +55°C)
Immune to electrical and radio frequency interference
9 feet of four-conductor cable with 5-pin connector
1.4 oz. (40g)
4"L (100 mm.) x 1"H (25 mm.) x 1.8"W (45 mm.)
Black
For details regarding the limited warranty:
Customer Service
1-877-671-7011
www.allegion.com/us
OPTIONAL ACCESSORIES:
Mask
Ceiling Adapter
Surface Adapter
© Allegion 2017
47259489 Rev 12/17-a

Advertisement

loading

Summary of Contents for Locknetics EMS-100 Series

  • Page 1: Product Description

    EMS-100 Series Exit motion sensor Instruction Product Description The EMS-100 is designed for use on request-to-exit applications with maglocks and electric strikes. This sensor is not an automatic door activation sensor. It is a request to exit sensor used to release a lock.The unit is a passive infrared detector that uses digital signature analysis for activation.
  • Page 2: Safety Precautions

    Safety Precautions • Shut off all power going to the header before attempting any wiring procedures. • Maintain a clean & safe environment when working in public areas. • Be constantly aware of pedestrian traffic around the door area. • Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
  • Page 3 Installation Instructions (cont.) Reinstall the mask (if needed.) The mask can only by installed one way. Place the mask inside the cover so that the legs of the mask slide into the clips. Gently work the mask’s legs into the cover until it clicks. Then the mask will be completely inside the cover (see picture.) If the masking lens needs to be removed from the cover, pry up with a screwdriver on the small legs of the lens.
  • Page 4: Mechanical Installation

    Mechanical Installation MOUNTING THE EMS-100 The sensor must be firmly fastened in order to avoid any vibrations. Make sure there are no objects in the sensing field that could move. Attach the template to the frame above the door. Drill and pass the cable through the template. Place the sensor on the template and attach with the two screws provided.