Download Print this page

Advertisement

Quick Links

Quick Reference Guide of WebEye B101
This information is to connect WebEye B101 on Internet of
dedicated line or local LAN. For different lines like xDSL,
cable and ISDN, please visit Download page in WebGate
Internet homepage and download related information.
http://www.webgateinc.com
WebGate Inc.

Advertisement

loading
Need help?

Need help?

Do you have a question about the WebEye B101 and is the answer not in the manual?

Questions and answers

Summary of Contents for WebGate WebEye B101

  • Page 1 Quick Reference Guide of WebEye B101 This information is to connect WebEye B101 on Internet of dedicated line or local LAN. For different lines like xDSL, cable and ISDN, please visit Download page in WebGate Internet homepage and download related information.
  • Page 2 I. Monitoring of real-time images through WebEye B101 1. PC and LAN requirements 1.1 PC requirements l CPU: Pentium II and above l RAM: 64MB and above l O/S: Windows 98/NT/Me/2000 1.2 Check display setting in your PC. 2. Select ‘Settings ’.
  • Page 3 5. Go to ‘Gateway’. 7. Go to ‘IP Address’ 6. Check gateway address. Check address and subnet mask. 1.4 Internet Browser Requirements l Internet Explorer 5.0 and above l Netscape Navigator 4.7 and above 1.5 Check LAN l The WebEye should be connected to a 10 Base-T LAN . 10 Base-T LAN is standard for network configuration.
  • Page 4 3. Connect LAN 4. The power input cable (RJ-45). jack. Use the included 12-volt power adapter. 6. After receiving power, yellow LED should go on for 5 -6 seconds and then 5. The green LED should blink go off. This LED starts to blink when every 1 -2 second (s) 1-2 seconds user accesses WebEye after receiving power.
  • Page 5 l To directly connect WebEye to a PC, use the red crossover cable. This connection is just to configure WebEye. Crossover cable Connect WebEye directly to a PC through LAN ports. * Crossover Cable and Direct Cable * The cro ssover cable (red) provided with the WebEye is used to connect the W ebEye with a PC. A HUB is not necessary to connect the WebEye to a PC if a crossover cable is used.
  • Page 6 1. Select the default IP address of WebEye (211.53.133.91). 5. After changing IP address, the new IP addres s appears. Click on 2. & 6. The selected IP address the IP address. appears (211.53.133.91). 3. Enter Admin’s password. Default 4. Click this button to change IP password is ‘admin’.
  • Page 7 l Please note!! When an IP address is assigned to the WebEye, be careful not to assign the WebEye with an IP address that is not compatible with the local network or that is already in use by another computer or similar device. Please refer below example and assign an IP address to WebEye.
  • Page 8 5.1 Select ‘Network Configuration’ in the menu and configure. 1. Click ‘Ethernet’ button. 2. Check if IP address is same as assigned at 3. Set Netmask. Setup program. 4 .This button makes WebEye set broadcast 5 . Set gateway address. If an address automatically.
  • Page 9 6. Access WebEye image viewer and configure watching condition 1. Enter IP address of your WebEye in the address bar of the Web browser (e.g. http://211.53.133.113) and press ‘Enter ’ key. 6.1 Enter IP address and access WebEye image viewer 5.
  • Page 10 3. Click ‘Download WebEye Plug-in Now!’ button. * This step is for Netscape Navigator users only. Internet Explorer users can skip this step. 4. Click ‘Grant’ button. ‘Install Successfully Completed’ will appear. * This step is for Explorer user s only. Netscape users disregard this step.
  • Page 11 If you experience a case that Active-X for Internet Explorer or Plug-in for Netscape Navigator is not installed into your PC properly, please visit ‘Download’ page in WebGate Internet homepage (http://www.webgateinc.com). And download a program to install Active-X or Plug-in manually.
  • Page 12 7. Manage the real-time image viewer. Set the desired viewer option. Simple viewer, server -push viewer, and java applet viewer viewer configurations are available in this menu. For more information, please refer to User’s guide. Images can be viewed in this section. To view Resolution, image other channels, connect external cameras and...
  • Page 13 II. Connecting external camera. 1. Functions of DIP switch. To designate video signal termination. To connect external CCTV cameras, place the switches in proper positions. Default positions of all 2 switches are up. 2. Connecting external camera to WebEye 2.1 Connection diagram. Video signal flows through LAN Cable.
  • Page 14 2.2 Connecting external camera to WebEye l Enter WebEye administrator’s page l Enter ‘Video Configuration’ page and configure. 1. Select ‘Enable’ to use the Choose ‘Color ’ channel. according ‘B/W ’ external camera type. 4. Click ‘Apply’ button. 3. Choose either NTSC o r PAL according to external camera type.
  • Page 15 1.4. Connecting CCTV monitor or PC to WebEye 1.4.1 Connection diagram Video signal flows through LAN Cable. DOME Camera Video signal flows through BNC Cable. CCTV monitor To monitor real - time image viewer through CCTV monitor or PC, connect Dome camera to ‘Video Input’ and CCTV monitor to ‘Video Output’.
  • Page 16 III. Connecting WebEye through firewall. 1. WebEye is blocked with firewall. l If there is a firewall in the network where WebEye is connected, enter WebEye administrator’s page and change TCP ports. 1. If default port (80) is blocked, change Web server TCP port to any other port that is open and is not occupied already on the network.
  • Page 17 2. User’s PC is blocked with firewall. l If there is a firewall on the network where your PC is connected, enter WebEye login page with IP address (ex: http://192.168.1.51). l Enter ID and password. l Click ‘behind firewal l’. l Click ‘Login’...
  • Page 18 For more detailed information on how to install PTZ mechanism, auto iris lens, external sensor and relay, please visit ‘Download ’ page in WebGate Internet homepage and download related information. http://www.webgateinc.com...