Gast 70 - 3005 G443PL Maintenance Manual

Gast 70 - 3005 G443PL Maintenance Manual

Oil-less diaphragm vacuum pumps & compressors

Advertisement

VACUUM PUMPS & COMPRESSORS
Thank you for purchasing this Gast product. It is manufactured to the highest standards
using quality materials. Please follow all recommended maintenance, operational
and safety instructions and you will receive years of trouble free service.
PLEASE READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND USING
Product Use Criteria:
• Pump only clean, dry air.
• Operate at 32ºF - 104ºF (0ºC - 40ºC).
• Protect unit from dirt & moisture.
• Do not pump flammable or explosive gases or
use in an atmosphere that contains such gases.
• Protect all surrounding items from exhaust air. This
exhaust air can become very hot.
• Corrosive gases and particulate material will
damage unit. Water vapor, oil-based contaminants
or other liquids must be filtered out.
• Consult your Gast Distributor/Representative
before using at high altitudes.
• This pump is oil-less and requires NO lubrication.
• Pressure units may be used for both pressure and vacuum.
Consult your Gast Distributor/Representative
to use vacuum units for pressure.
®Registered Trademark/™Trademark of Gast Manufacturing Inc., Copyright © 2002 Gast Manufacturing Inc. All Rights Reserved.
OIL-LESS DIAPHRAGM
O
& M
PERATION
Model DOA Shown
WARNING
THIS PRODUCT. SAVE THIS MANUAL FOR FUTURE REFERENCE AND
KEEP IN THE VICINITY OF THE PRODUCT
ISO 9001 & 14001 CERTIFIED
PART NO. 70 - 3005 G443PL (Rev. D)
M
AINTENANCE
Model DAA Shown
www.gastmfg.com
ANUAL
1

Advertisement

Table of Contents
loading

Summary of Contents for Gast 70 - 3005 G443PL

  • Page 1 • Pressure units may be used for both pressure and vacuum. Consult your Gast Distributor/Representative to use vacuum units for pressure. www.gastmfg.com ISO 9001 & 14001 CERTIFIED ®Registered Trademark/™Trademark of Gast Manufacturing Inc., Copyright © 2002 Gast Manufacturing Inc. All Rights Reserved.
  • Page 2: Installation

    The safety alert symbol and the words These should be checked periodically and replaced when necessary. Please consult your Gast “DANGER” and “WARNING” will precede all safety Distributor/Representative for additional filter messages.
  • Page 3: Operation

    -Minimum gage for extension cords DIAGRAM A Amps Volts Length of cord in feet 120v 150 200 250 300 400 500 240v 100 200 300 400 500 600 800 1000 Grounded Plug Grounding Pin 120-volt grounded connectors 8-10 shown. 220 /240-volt grounded 10-12 Grounded Outlet connectors will differ in shape.
  • Page 4: Maintenance

    1. Remove the four bolts holding the head on. before installing service kit. 2. Remove filters and clean with Gast recommended Disconnect air supply and vent all air lines to solvent or other non-petroleum based solvent.
  • Page 5: Warranty

    Gast Manufacturing Incorporated, PO Box 97, Benton Harbor Michigan USA 49023-0097 or an authorized Service Center (unless specifically agreed upon in writing signed by both parties or specified in writing as part of a Gast OEM Quotation). Buyer is responsible for freight charges both to and from Gast in all cases.
  • Page 6: Parts & Ordering Information

    PARTS & ORDERING INFORMATION Please reference the exploded views on the next page for the following model and parts table. DAA / DOA / DOL SERIES DESCRIPTION DOA-P701-AA DAA-P501-EB* DOL-701-AA DAA-V701-EB* DOA-P501-BN DOA-P501- JH HEAD AP500 AP500 2 ∆ HEAD O-RING AP513 AP513 3 ∆...
  • Page 7 EXPLODED PRODUCT VIEWS - MODEL DOA & VALVE PLATE ASSEMBLY Valve Plate Assembly (available separately) (Valve Plate Assembly also includes items 7 & 8, as shown in the main exploded view)
  • Page 8: Troubleshooting Chart

    PART NO. 70 - 3005 G443PL (Rev. D) TROUBLESHOOTING CHART High Pump Motor Excess Reason and remedy Vacuum Pressure Vacuum Pressure Overheat Overload Noise for problem. • • At Pump Filter dirty. Clean or replace. • • At pump Muffler dirty. Clean or replace.

Table of Contents