Download Print this page

NL Premier User Instructions

Loss prevention lp locks

Advertisement

Quick Links

Premier User Instructions
General
The lock operates with a six-digit code. When pressed, each key is confirmed with an audio and LED
signal.
After entry of a valid code a double signal will follow. An invalid entry is followed by a long signal. After
10 seconds without entry, current code being entered will be cancelled.
The lock comes standard with a night light. To activate the light, press the light bulb on the lower left side
of the keypad before entering your code.
Open
Enter code (Factory User code = 1-2-3-4-5-6), unlock door and open. If not opened within 3 seconds, the
lock secures automatically. If code entry failed on first attempt wait 20 seconds before re-entering.
Locking:
Close door and turn handle fully to closing position. The lock is secured. Verify locked status by trying
to turn handle back.
Manipulation protection:
Entry of four consecutive invalid codes-keypad is blocked for 5 minutes. During this period, the LED
flashes every 10 seconds and any key pressed causes a long signal. After expiration, entry of two more
invalid codes, restarts the 5 minute blocking period.
Security reference:
All codes are to be securely stored. Do not use personal data (i.e. birthdays, telephone numbers etc.)
as the code.
Change Code (With Safe Door OPEN)
Press and Hold Key [0] until double signal. The LED remains on during the following actions:
• Enter old code (double signal)
• Enter new code (double signal) and repeat new code (double signal)
• Try new code
• In case of entry errors (long signal), the old code remains valid.
Battery Low Warning and Battery Change
A series of signals indicates that the battery is weak and must be replaced. Use only 9V ALKALINE—
batteries! The battery compartment is located at the bottom of the entry unit.
Fresh Duracell and Energizer Batteries Recommended