Download Print this page

ZLINK PD-100 Instruction Manual

Advertisement

Quick Links

Connecting Things That Matter
PD-100
This product speaks
with other Z-Wave
Plug In Dimmer
cer�fied devices
INTRODUCTION
ZLINK PD-100 is a Z-Wave Plus® cer�fied device with S2 security and SmartStart
features. You can now add this device securely and with ease using QR code on the
product with compa�ble gateways suppor�ng S2 and Smart Start. PD-100 is a
member of the Z-Wave family and communicates with other Z-Wave cer�fied
devices in a control network. PD-100 can be used to turn any plug in lamps On, Off,
or control dimming of any lamps with dimmable light bulbs. Each Z-Wave device also
serves as a node to repeat the signal in the network, thus, extending the overall
Z-Wave mesh wireless network range. Different types and brands of Z-Wave devices
can be associated with the PD-100 in your system and they will work together to
op�mize and expand the coverage of your Z-Wave network. For more informa�on on
this and other quality ZLINK Products please visit www.ZLINKProducts.com.
FEATURES
Works with any AC operated lamps with incandescent and dimmable
florescent (CFL) or LED light bulbs
ON/OFF status and loca�on LED indicator
Remotely or manually turns ON or OFF, or DIM lights
Does not block the second AC outlet
Z-Wave 500 Series module inside
Internal rese�able fuse to protect from surge current
Works with any cer�fied gateway suppor�ng Z-Wave
Z-Wave 500 Series module inside
Please find the QR code label with DSK on the bo�om of the device.
! WARNING !
RISK OF FIRE, ELECTRICAL SHOCK & BURNS
DO NOT USE WITH MEDICAL AND LIFE SUPPORT INSTRUMENT
No user serviceable parts are in this module
To reduce the risk of electric shock, this product has a grounding type plug that has a
third (grounding) pin. This plug will only fit into a grounding type power outlet. If the
plug does not fit into the outlet, contact a qualified electrician to install the proper
outlet. Do not change the plug in any way
CAUTION: To Reduce the Risk of Overhea�ng And Possible Damage To Other
Equipment, Do Not Install To Control A Motor-Operated Appliance,
A Non-Dimmable Fluorescent Ligh�ng Fixture, Or A Transformer-Supplied Appliance
The ligh�ng devices connected to this Z-Wave module must not exceed 2.5A, 300W
incandescent, 65W dimmable CFL/LED.
SETUP
Step 1
Plug the 2-pin AC power plugs of ligh�ng
device to the receptacle of PD-100.
Step 2 Insert the module's 3-pin plug into an AC
outlet in the same room as your gateway.
In normal opera�ng mode, the LED on the
front panel will be lit.
Step 3 Add (Include) the module into your network by a Z-Wave cer�fied controller.
Please refer to your gateway's or the controller's instruc�ons manual for details.
Normally, the sequence is as follows:
1. Place your network controller into inclusion mode by following the controller
manufacturer's instruc�ons.
2. When the controller is ready, single click the bu�on on the front of PD-100.
The controller should indicate that the new device was added successfully
3. Once PD-100 has been successfully added to your home network, you can
move it to the preferred loca�on in the home.
If the controller shows it failed, repeat the procedure.
Manual Reset
If Inclusion s�ll fails a�er the 2nd a�empt, you need to first reset the PD-100
before repea�ng the above step. The manual reset method is as follows:
1. Unplug PD-100 from the AC outlet and
also unplug the power plug of the
appliance from PD-100 (if plugged in).
2. Press and hold the bu�on on the PD-100.
www.ZLINKProducts.com
3. Plug the PD-100 back into the AC outlet with the bu�on pressed
A�er 3 seconds, release the bu�on. If you see the bu�on blink, that means that
PD-100 has been reset successfully and you may retry Step 3 above to add the
module into your network. Otherwise, please repeat the manual reset procedure.
Note: If the PD-100 was previously Added (Included) in your network, rese�ng it
locally does not mean it has been removed from your network. If you wish to
remove PD-100 from your network you will need to Delete (Exclude) the module
from the network by your controller.
Use the manual reset procedure only in the event that the network primary
controller is lost or otherwise inoperable.
BASIC OPERATION
The connected ligh�ng devices can be controlled manually with a push bu�on
OR Wirelessly with a remotely
Press here
A Z-Wave cer�fied controller is capable of se�ng up ZLINK products in your
desired network. Once the device is added, you may assign it to a Group.
Furthermore, it can be set in Associa�on with another Z-Wave device to
perform a specific triggered func�on such as turning lights on when mo�on
is detected. Please refer to the instruc�ons manual of your controller for
details and procedures on how these se�ngs can be done.
In the event of a power failure, the ZLINK device will return to the last dimming
level a�er the power is restored.
About the push bu�on:
There is a single bu�on on PD-100 for manual opera�on that:
A)
Manually turns the connected ligh�ng ON/OFF by pressing the bu�on. It
func�ons as a toggle switch; if the light is ON, pressing the bu�on turns
the light OFF and vice a versa.
B)
Adjust the brightness level of the connected ligh�ng by pressing and
holding the bu�on. Release the bu�on when the desired level is reached.
It func�ons as a toggle switch as well. The ligh�ng keeps dimming un�l the
minimum level is reached or the bu�on is released. When you press the
bu�on again and hold, the brightness of the light will keep increasing un�l
the maximum level is reached or when the bu�on is released.
Adds(Includes) or Deletes(Excludes) your PD-100 to/from your Z-Wave
C)
network. Please refer to the instruc�ons manual of your gateway or
remote controller for detail procedures on how these ac�ons can be done.
This push bu�on is also backlit with an LED indicator that will be On when the
connected appliance is Off, and vice versa. The module may be easily spo�ed
even in a dark environment.
www.ZLINKProducts.com

Advertisement

loading

Summary of Contents for ZLINK PD-100

  • Page 1 A�er 3 seconds, release the bu�on. If you see the bu�on blink, that means that devices in a control network. PD-100 can be used to turn any plug in lamps On, Off, PD-100 has been reset successfully and you may retry Step 3 above to add the or control dimming of any lamps with dimmable light bulbs.
  • Page 2 3. Lifeline associa�on only supports the "manual reset" event. 4. For instruc�ons on how to “set lifeline associate”, please refer to your controller/ ZLINK warrants to the original purchaser of this product that for the warranty period, gateway instruc�ons. this product will be free from material defects in materials and workmanship.