MSA4H/V: 4 Button Wall Switch V1.0
MSA4H (horizontal)
MSA4V (vertical)

Description

The MSA4H/V is designed to work with the Imperial system's
MAMA home automation engine. Each button can be
programmed to control a single output, multiple outputs, or
macros. The wall switch can provide on/off control of lights,
sprinklers or macros, set lights to a fixed dimming level, or
open motorized shutters to a preset height.
All wall switches are driven by the V32 Main Controller's 4 wire
low-voltage Multibus. This means that the high voltage wiring is
not connected directly to the switch as in regular electrical
systems. Since the wall switches use low-voltage bus
communication, they can be installed anywhere including wet
areas or outdoors (avoiding direct sunlight, or exposure to rain/
snow).
Up to 510 wall switches can be programmed to control one
output, as opposed to a maximum of 3 switches or 1
dimmer knob in regular electrical systems.

Overview

1) Output and macro control buttons
2) Button lights
3) Button label window and label lights
4) Multibus feedback LEDs
5) Label trays
6) 4-wire Multibus connection
NOTE: For more detailed installation and programming
instructions, refer to the Imperial System Guide.

Features

4 buttons to control outputs (lights, sprinklers, shutters,
etc.) or macros (group of outputs)
Multiple switches can control the same output (max. 510)
Custom designer colours available
Set in Toggle mode (1 button on/off) or Switch mode (1
button on / 1 button off)
Adjustable Day/Night LED brightness
Remote firmware upgrade via Multibus using RS485 at
57.6Kbps
All programming is done using BabyWare PC Software
Bi-directional Module Locate feature
Connects to Multibus: 4-wire encrypted 13.8 VDC
communication bus
Single gang box installation (for dimensions, refer to

Specifications)

1
5
6
4
Specifications
TM
Multibus rating
13.8 VDC Class 2; 35 mA
Dimensions
7.4 X 11 X 2.5 cm (2.9 X 4.3 X 1 in.)
Operating
-10ºC to 50ºC
temperature
(14ºF to 122ºF)

Wiring

LED Feedback

R = Red G = Green B = Blue
MULTIBUS
OK: Communication in
BUS
progress
G
RX
TX
G
BUS
R
Com fail: GRN/YEL short /
no data / Multibus in
RX
RS485 mode
TX
BUS R
Com fail: too many
modules / wrong data
RX
TX
G
Button 1
2
Firmware upgrade in
LED
progress
3
Rapid flash
NOTE: "BUS" LED may be labeled "ERR" on some hardware versions.
Connecting an MSA4H/V
WARNING: To avoid damage when
installing and servicing, observe
Imperial
proper ESD precautions.
Multibus
NOTE: Wiring methods must be in
accordance with the National Electrical
Code ANSI/NFPA 70.
= Off
= On
= Flashing
BUS R
Com fail: GRN/YEL reversed
RX
G
TX
G
BUS
R
Bus power too low
RX
BUTTONS
TX
Press to activate/deactivate the button's
associated output or action (refer to
BUS R
Module Locate mode
Programming an MSA4H/V Wall Switch
G
RX
in the Imperial System Guide).
TX
G
R
Button activated
Button deactivated

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSA4V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Paradox MSA4V

  • Page 1: Specifications

    (14ºF to 122ºF) Wiring Connecting an MSA4H/V MSA4H (horizontal) NOTE: For more detailed installation and programming WARNING: To avoid damage when instructions, refer to the Imperial System Guide. MSA4V (vertical) installing and servicing, observe Imperial proper ESD precautions. Description Features Multibus NOTE: Wiring methods must be in The MSA4H/V is designed to work with the Imperial system’s...
  • Page 2 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply. Trademarks: Paradox Imperial, MAMA, BabyWare, the M logo, and the triangle logo are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.

This manual is also suitable for:

Msa4h

Table of Contents