Zeroplus LAP-C(16032) User Manual

Lap-a series; lap-b series; lap-c series; lap-d series

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Zeroplus LAP-C(16032)

  • Page 2: Table Of Contents

    Smart+ User’s Manual V1.04.04 Index Features of Zeroplus Logic Analyzer ........................... 4 Welcome choosing the product of Zeroplus Technology ..................5 Package Contents ..............................5 Introduction ................................. 8 Specifications ..............................11 Special Functions and Patents Introduction ....................... 15 1.5.1 Bus Wizard ................................ 15 1.5.2...
  • Page 3 Smart+ User’s Manual V1.04.04 4.12 Connect to DSO ..............................86 4.13 Noise Filter Setup .............................. 90 4.14 Files Comparison .............................. 91 4.15 Math Operation ..............................94 Go To…................................96 4.16 4.17 Specific Bus Data Display ..........................99 4.18 Signal Activity..............................100 4.19 Navigator.................................
  • Page 4: Features Of Zeroplus Logic Analyzer

    Smart+ User’s Manual V1.04.04 1 Features of Zeroplus Logic Analyzer 1.1 Welcome choosing the product of Zeroplus Technology 1.2 Package Contents 1.3 Introduction 1.4 Specifications 1.5 Special Functions and Patents Introduction 1.6 System Requirements 1.7 Device Maintenance and Safety FM07I4A...
  • Page 5: Welcome Choosing The Product Of Zeroplus Technology

    Zeroplus Technology, though a new company in instrument industry, spares no effort to develop new technology, apply for patents and control the quality. The products of Zeroplus Technology are well acknowledged in the industry, so we assure that your choice can’t be wrong.
  • Page 6 Smart+ User’s Manual V1.04.04 Models LAP-D(32064M) LAP-D(32512M) USB Cable 16Pin*1 16Pin*1 8Pin*2 8Pin*2 Testing Cable 2Pin*1 2Pin*1 1Pin*1 1Pin*1 Probe Driver CD Quick Start Guide Below table shows the package contents of LAP-C Series products. 16 Pin x 1 8 Pin x 2 Fig 1-1: Logic Analyzer Fig 1-2: Testing Cable Fig 1-3: Probe (differentiated by the model)
  • Page 7 Smart+ User’s Manual V1.04.04 Below table shows the package contents of LAP-D Series products. Fig 1-9: Logic Analyzer Fig 1-10: Testing Cable Fig 1-11: Probe Fig 1-12:USB Cable Fig 1-13: Quick Start Guide Fig 1-14: Driver CD Fig 1-16: AC Power Line Fig 1-15: BNC Cable Fig 1-17: Carry-on Bag Fig 1-18: DC Transformer...
  • Page 8: Introduction

    Smart+ User’s Manual V1.04.04 Introduction Description for LAP-C Series Models: The USB connection supply the power. FM07I4A...
  • Page 9 Smart+ User’s Manual V1.04.04 Description for LAP-D Series Models: Front view of LAP-D ports. (Refer to the table 1-1 for the detailed port names) Table 1-1: List of available channels. LAP-D (32064M)/ Models LAP-D(32512M) Port A ( A0~A7) (A8~A15) Port B ( B0~B7) (B8~B15) 3.3V 3.3V Voltage Outputting...
  • Page 10 Smart+ User’s Manual V1.04.04 Table 1-2: List of special function pins When the condition is met (such as the trigger Trigger Trigger Out occurs, start capturing, stop capturing), the Pins Trigger Out will send out a 3.3V [Rising Edge/Falling Edge/Status] signal. Function Function Pin NO.
  • Page 11: Specifications

    Smart+ User’s Manual V1.04.04 Specifications Model LAP-C(16032) LAP-C(16064) LAP-C(16128) Windows XP/Vista/Windows 7 Operating System Interface USB 2.0(1.1) Power Supply Internal(Clock) 100Hz~100MHz 100Hz~100MHz 100Hz~200MHz (Asynchronous) Sampling External(Status) Frequency 75MHz 75MHz 100MHz (Asynchronous) Bandwidth 75MHz 75MHz 75MHz Memory 512Kbits 1Mbits 4Mbits 32 K bits(Max 64 K bits(Max 128 K bits (Max Memory...
  • Page 12 Smart+ User’s Manual V1.04.04 Bandwidth 75MHz Memory 64Mbits 4Mbits 64Mbits 2Mbits(Max 128Kbits(Max Memory Memory 2Mbits(Max 512Mbits for 512Mbits for 32Mbits for (Per Channel) Compression) Compression) Compression) Trigger Channel 16CH Trigger Condition Pattern/Edge Pre-Trigger/ Post-Trigger Trigger Pulse Width Free Trigger Trigger Level 1 Level Trigger Count 1~65536...
  • Page 13 Smart+ User’s Manual V1.04.04 Pre-Trigger/ Post-Trigger Pulse Width Free Trigger Trigger Level 1 Level Trigger Count 1~65536 Working Voltage -6V~+6V Threshold Voltage Accuracy ±0.1V Operating Interface Chinese(Si)/ Chinese(Tr)/ English Language Time Base Range 5ps~10Ms Waveform 1~5.5 Vertical Scaling Signal Filter and Delay Compression Max 32Mbits...
  • Page 14 Smart+ User’s Manual V1.04.04 Trigger Interval 1s~30d Model LAP-D(32064M) Channel Mode 32CH 16CH Interface USB 2.0 (1.1) Windows XP/Vista /Windows 7 Operating System 32CH 16CH Measurement Channel Input Bandwidth 400MHz Trigger Voltage Range -5V~+5V Trigger Voltage 0.1V Accuracy 2Gbits Memory 64 Mbits 128 Mbits 256 Mbits...
  • Page 15: Special Functions And Patents Introduction

    ·Waveform Data Display (Patent Taiwan I267646) Zeroplus Logic Analyzer can display the waveform time. Users can decide whether to display the time of waveform width(between two rising edges or falling edges) or not in the waveform display window. There are three modes: Sampling Site Display, Time Display, Frequency Display.
  • Page 16 Smart+ User’s Manual V1.04.04 Bus Packet List: The Smart+ software can display the packet status of various protocol analyzer through the bus decoding module. Users can use the Bus Packet List function to display huge packet data in a list, with which analyzing the relation between each packet becomes much easy.
  • Page 17: System Requirements

    Smart+ User’s Manual V1.04.04 System Requirements Operating System Requirements: Support Non-support  Windows XP  Windows NT 4.0 (Workstation & (Home, Professional Editions 32-Bit Server, Service Pack 6) version)  Windows Server 2003  Windows VISTA Operating (32-bit and 64-bit version) System Name ...
  • Page 18: Device Maintenance And Safety

     Use a soft, damp cloth with mild detergent to clean.  Do not spray any liquid on the Zeroplus Logic Analyzer or Cleaning immerse it in any liquid.  Do not use harsh chemicals or cleaners containing substances such as benzene, toluene, xylene or acetone.
  • Page 19 Smart+ User’s Manual V1.04.04 Operating Environment:  Avoid direct sunlight  Use in a dust free, non-conductive environment (see Note)  Relative Humidity: < 80%  Altitude: < 2000m  Temperature: 0 ~ 40 Degrees As a Class A product, it may cause radio interference in a domestic environment.
  • Page 20: Installation

    Smart+ User’s Manual V1.04.04 2 Installation 2.1 Software Installation 2.2 Hardware Installation 2.3 Tips and Advice FM07I4A...
  • Page 21: Software Installation

    STEP 1. Close all programs firstly. driver CD into the CD-ROM. If the CD can auto-play, click “Application Setup” STEP 2. Place the Zeroplus Smart firstly and then click “Driver Setup” to make sure the Logic Analyzer can work normally.
  • Page 22 Smart+ User’s Manual V1.04.04 STEP 5. If users accept the agreement, click “Next” continuously if the options are no need to change(be default) , and click “Finish” to complete the installation. The Finish page reminds users to restart the computer now or later; recommend to select “Yes, I want to restart my computer now”.
  • Page 23: Hardware Installation

    Smart+ User’s Manual V1.04.04 Hardware Installation Connect the B-type connector (of the attached USB connect line) with the B-type socket of Logic Analyzer and the A-type with the A-type socket of computer. Keep the power being on. LAP-C Series: LAP-D Series: FM07I4A...
  • Page 24: Tips And Advice

    (Fig. 2-3). Fig. 2-3 4. If the internet is available, the Logic Analyzer will connect with the Zeroplus Server automatically and search for update. 5. Unwanted signals can be filtered by the “Signal Filter” or “Signal Filter Delay” function.
  • Page 25: Users Interface

    Smart+ User’s Manual V1.04.04 3 Users Interface User Interface Main Menu Right Key Menu Common Tools FM07I4A...
  • Page 26: User Interface

    Smart+ User’s Manual V1.04.04 User Interface 1. The Interface can be classified into the following sections: A. Menu Bar All operations are included in the menu bar, including File(F), Acquisition(A), Hardware(H), Analysis(D), View(V) and Help(H). B. Tool Bar The tool bar consists of graphical icons of the most frequently used functions. Users can set or operate the Logic Analyzer more easily.
  • Page 27 Smart+ User’s Manual V1.04.04 Bar, B Bar and other Bar. See below details: Scale: Interval time width of each sampling site. Total: Total time length of current data capturing. Display Pos: The middle position of display area. Display Range: The waveform time range of current waveform view area. A Pos: The position of A Bar.
  • Page 28 Smart+ User’s Manual V1.04.04 to switch to external clock. External Clock: Users can input the value or drag the pointer of knob to adjust. If the cursor is on the knob, users can use the roller to adjust. The sampling signal can be set as Rising Edge, Falling Edge or Either Edge...
  • Page 29: Main Menu

    Smart+ User’s Manual V1.04.04 Main Menu 3.2.1 File(F) Menu New: Create a new file; 12 files can be created at most(determined by the free disk space). Open: Open an exist file. The software supports formats of *.als, *.alc and *.lap; if opens *.als or *.alc file, it will automatically convert them to *.lap file.
  • Page 30 RAM size, with higher resolution and not wasting RAM size. The compression rate of Zeroplus Logic Analyzer can be up to 255 times. That’s mean when the RAM size is 128K, each channel can store as much as 32 M bits(128K*255) data.
  • Page 31 Smart+ User’s Manual V1.04.04 8CH/1.6GHz: 8 Channels, 1.6GHz sampling frequency at most. The RAM size is double of that of 16CH/800MHz Mode. 16CH/800MHz: 16 Channels, 800MHz sampling frequency at most. The RAM size is double of that of 32CH/800MHz Mode. 32CH/400MHz: 32 Channels, 400MHz sampling frequency at most.
  • Page 32 Smart+ User’s Manual V1.04.04 Numeric Base/Encoding: The data format has 7 types: Binary, Decimal, Decimal(Signed), Hexadecimal, ASCII, Gray Code and Complement. The default is Hexadecimal. 3.2.6 View(V) Menu Cursor Type: Normal: Select an area to zoom by dragging the left key. Dragging the waveform from left to right can zoom in the area; dragging it from right to left can zoom out the area.
  • Page 33 Smart+ User’s Manual V1.04.04 State List: Display logic status. Logic 0 signal is displayed as ‘0’, logic 1 signal is displayed as ‘1’, unknown signal is displayed as ‘U’, see below image: FM07I4A...
  • Page 34 Smart+ User’s Manual V1.04.04 Refresh: After the “Select an Analytic Range” is activated, users can click it to refresh the selected data. Zoom: Zoom In: Zoom in the waveform. Unavailable in Listing Window. Zoom Out: Zoom out the waveform. Unavailable in Listing Window. Fit to Screen: Show all data between Ds and Dp in the waveform view area.
  • Page 35 Hot Keys: Open the list of Hot keys. Send Feedback: If users have any problem about the software, they can send it with software parameters and PC system parameters to Zeroplus through the ‘Send Feedback’ dialog box ( Email address: service@zeroplus.com.tw). About ZEROPLUS: Login the Zeroplus website.
  • Page 36: Right Key Menu

    Smart+ User’s Manual V1.04.04 Right Key Menu 3.3.1 Right Key Menu of Channel Column Add Channel/Bus: Add Channel, Bus or Protocol Analyzer. Copy: Copy the selected channel or Bus/Protocol Analyzer. Using along with Shift or Ctrl key can copy more channels or Buses/Protocol Analyzers together.
  • Page 37 Smart+ User’s Manual V1.04.04 3.3.2 Right Key Menu of Trigger and Filter Columns Don’t Care: Ignore all trigger/filter settings. High: Set high level as the trigger condition or filter condition for the selected channel. Low: Set low level as the trigger condition or filter condition for the selected channel. Rising Edge: Set Rising Edge as the trigger condition for the selected channel.
  • Page 38 Smart+ User’s Manual V1.04.04 3.3.4 Right Key Menu of Bar Set As Trigger Condition: Set the high, low or edge of each channel the bar locates as the trigger condition, which will be the same with that of the channel area. Delete Bar: Delete the selected bar.
  • Page 39: Common Toolbar

    Smart+ User’s Manual V1.04.04 Add Channel/Bus: Add Channel, Bus or Protocol Analyzer. Bus/Protocol Analyzer Property: Set the parameters for the Bus or Protocol Analyzer. Different Bus or Protocol Analyzer has different interface. Format Row: The channel position can be auto sized or moved left/right. Common Toolbar : Create a new document.
  • Page 40 : Go to : Keyboard Map. Place B Bar in the middle of screen. : Send Feedback. : Place B Bar in the middle of screen. : About ZEROPLUS. : Place T Bar in the middle of screen. : About smart+. FM07I4A...
  • Page 41: Software Introduction

    Smart+ User’s Manual V1.04.04 4 Software Introduction 4.1 Save Setup 4.2 Export Setup 4.3 Screen Capture 4.4 Print Setup 4.5 Options 4.6 Acquisition Setup 4.7 Trigger and Find Setup 4.8 External Trigger 4.9 Signal Filter Setup 4.10 Add Channel/Bus Setup 4.11 Connect Multiple smart+ 4.12 Connect to DSO 4.13 Noise Filter Setup...
  • Page 42: Save Setup

    Smart+ User’s Manual V1.04.04 Save Setup 4.1.1. Open The ‘Open’ dialog box could show the information of selected file. The software supports formats of *.als, *.alc and *.lap; if opens *.als or *.alc file, it will automatically convert them to *.lap file. For models in same series, high-level ones could open the files saved by low-level ones, for example: LAP-C(322000) model could open the file of LAP-C(32128) model.
  • Page 43: Export Setup

    Smart+ User’s Manual V1.04.04 4.1.2 Save As In this dialog box, users can save the summary information, so they can preview it before opening the file next time. File could be saved in format of *.lap and *.alc. If a file is saved in *.alc format, then it only could be opened by LAP-C Series models of V3.12 or higher.
  • Page 44 Smart+ User’s Manual V1.04.04 File name: Input the file name, the default is Wave. Save as type: Save the file as txt or csv, the default is txt. Include environment info : Export the file with detailed parameters(such as file information, related settings and others) or not.
  • Page 45 Smart+ User’s Manual V1.04.04 All Data->Export all data. Show changes in state only->Export data only when change happens to any channel. Show changes in data only->Export data only when the change happens to any Bus(Protocol Decoder). Bus Selection: Choose the Bus data that needed to be exported. Range: Set the data range to export.
  • Page 46 Smart+ User’s Manual V1.04.04 File Name: Input the file name, the default is Packet. Save as type: Select the type as txt or CSV, the default is txt. Range: Set the data range to export. The range can be: Beginning of Data, End of Data, T Bar, A Bar, B Bar, Page and User Defined (Set by time or sampling site).
  • Page 47: Screen Capture

    Smart+ User’s Manual V1.04.04 Users can export and save the data of the Memory Analyzer List Window as txt, CSV or Bin format. Screen Capture FM07I4A...
  • Page 48: Print Setup

    Smart+ User’s Manual V1.04.04 Capture to…: File->Save the captured region in JPEG or BMP format with a name. Clipboard->Copy the captured region to the clipboard. Users can paste it in other picture editing software. Ms Paint->Open the captured region by Ms Paint. Capture Region: Full Screen->Capture the full screen.
  • Page 49: Options

    Smart+ User’s Manual V1.04.04 Name: Select the Printer and click “Properties” to set; the settings must be saved. Print range: All->Print all data in the waveform view area. Pages->Print pages in a specified range. Current Page->Print the data of the current page. Options 4.5.1 General FM07I4A...
  • Page 50 Smart+ User’s Manual V1.04.04 Select Language: Chinese(Si), Chinese(Tr) and English are preinstalled, the default is the language selected during installation. In the future more languages will be provided in individual files. The software will auto-detect the new installed language and allow it be used by users. Post Capture Options: For the question “When pressing Stop during sampling”, users can select “Show present acquisition”...
  • Page 51 Smart+ User’s Manual V1.04.04 System Prompts: Hardware Mode SwitchRemind users to change the hardware mode. It is selected by default. Modification DescriptionDescribe the modification information. It is selected by default. Open the last used file when starting a new session It will remind users to open the last saved file when they open the software, it is selected by default.
  • Page 52 Smart+ User’s Manual V1.04.04 Standard group cannot be deleted, but the other groups(including new added group) can be deleted or renamed. Group: All options are not selected by default. Dictates can classified into various groups. Item: The icons belong to the selected group will be selected. Autohide: The toolbar will hide if the cursor is out of its area.
  • Page 53 Smart+ User’s Manual V1.04.04 Color Settings: Users can change the color of the selected item. Preview: Preview the color change of the selected item. Black and white: Make the waveform view area be black and white. Contrast: After the background is altered, the color of related items will change to the contrast color automatically. Click the color button of any item, the following color dialog box will appear.
  • Page 54 Smart+ User’s Manual V1.04.04 If users can’t find proper color in the Color dialog box, they can click the “Define Custom Colors” button, the following color box will appear. Then users can select the color in the color box, or pull the small triangle to change the lightness if necessary.
  • Page 55 Smart+ User’s Manual V1.04.04 If users want to change the color of sampling position, they could click the color block of ‘Sampling point marks’. FM07I4A...
  • Page 56 Smart+ User’s Manual V1.04.04 Before color changed, the sampling position is yellow. After changed, the sampling position is red. FM07I4A...
  • Page 57 Smart+ User’s Manual V1.04.04 4.5.5 Waveform FM07I4A...
  • Page 58 Smart+ User’s Manual V1.04.04 Trace Information: Users can select Don’t show values, Frequency, Number of sampling or Time, the default is Don’t show values . 1. Don’t show values : The waveform will be displayed without the time and data. 2.
  • Page 59 Smart+ User’s Manual V1.04.04 3. Number of sampling : The waveform will be displayed with the sampling site. 4. Time: The waveform will be displayed with the time. Waveform Options: Trace Height: Set the waveform amplitude. Users can input the value between 1 and 180, or select the value form the pull down menu which including 18, 20, 22, 24, 26, 28, 30, 40, 50, 60, 70, 80, 90 and 100, the default is 26.
  • Page 60 Smart+ User’s Manual V1.04.04 Sampling/Time: If the Waveform Display Mode is Hide Time of Waveform or Sampling Site Display, the Ruler will be displayed by grids, or by time unit. The default is Time/Sampling Ruler. Snap to Edges: The bar will approach the nearest waveform edge automatically when being moved. This option is selected by default.
  • Page 61: Acquisition Setup

    Smart+ User’s Manual V1.04.04 File Name: Input the file name, the default is LA. Path: The path to save the file, the default is C:\Documents and settings\Administrator\ My Documents\ LA Data (C disk is the system disk). Save acquisitions automatically: The software will auto-save the file if the trigger condition is satisfied. Keep time from first save;...
  • Page 62: Trigger And Find Setup

    Smart+ User’s Manual V1.04.04 Internal Clock: The sampling frequency range is 10Hz ~400MHz. Users can select the value from the pulldown menu. For LAP-C Series, users can input the sampling frequency between 100Hz and 200MHz; for 16032 and 16064 models, their sampling frequency is between 100Hz and 100MHz.
  • Page 63 Smart+ User’s Manual V1.04.04 Trigger Condition Setting : Set the trigger settings of the current page as the trigger condition. Clear Trigger Condition : Clear the trigger settings of the current page and restore to the original status. Channel Parameter: Each channel can be set as Don’t Care, Low Level, High Level, Rising Edge, Falling Edge and Either Edge.
  • Page 64 Smart+ User’s Manual V1.04.04 Listing interface For the Multi-level Trigger, click to the graphical interface, click to the listing interface. Level Condition: Set the condition for the level(s)( 256 levels at most). Double click √ or × can activate or close the level.
  • Page 65 Smart+ User’s Manual V1.04.04 Packet: The Bus packet is Data. The Protocol Analyzer packet is different according to different Protocol Analyzer. Condition: Set the Find condition, which includes “==”, “!=”, “In Range”, “Not In Range”, “<”, “>”, “String” and “None”. Only “= =” can be set as trigger condition. “None” could help to count the packets and find particular packet. Min: Only when condition is “= =”, “!=”,”, “In Range”, “Not Range”, “<”...
  • Page 66 Smart+ User’s Manual V1.04.04 If this function is not activated, click the icon “Trigger Condition Setting” to pop up the purchase dialog box, in which click “Purchase” to login ZPP Store to purchase this function. 4.6.4 Trigger and Find (Trigger Option) Click the button of “Trigger Option”...
  • Page 67 Smart+ User’s Manual V1.04.04 Page 8192 8192 8192 1024 1024 1024 128K This capability This capability doesn’t 256K doesn’t exist ! exist ! Applicable LAP-C(16128+) LAP-C(162000) LAP-C(162000+) Models Page 8192 8192 8192 1024 1024 1024 128K 256K 512K This capability doesn’t exist ! Applicable LAP-C(32128)...
  • Page 68 Smart+ User’s Manual V1.04.04 Clicking “Purchase” would pop up below purchase dialog box. In this dialog box, click “Purchase” to login the ZPP Store to purchase this function. Trigger Count: Set the trigger count. The value can be set between 1-65535, or select one from the pulldown menu( 1, 2, 3, 4, 5, 10, 15 and 20).
  • Page 69 Smart+ User’s Manual V1.04.04 4.6.5 Trigger and Find (Find Option) Click the button of “Find Option” to expand or collapse the find options. Find Range: Set the data range to find. The Start can be set as Ds, T, A, B, All or any current bar. The End can be set as Dp, A, B or any current bar, but it is disabled if the Start is All.
  • Page 70: External Trigger (Only Supported By Lap-D Series)

    Smart+ User’s Manual V1.04.04 Reset Find: Find the data that fitting the condition again from the start point. Previous: Find the previous data that fitting the condition. Next: Find the next data that fitting the condition.  Note 1: If one condition page is set as trigger condition, it would be marked by a ‘*’. ...
  • Page 71: Add Channel/Bus Setup

    Smart+ User’s Manual V1.04.04 Channel Selection: Each channel can be set as Don’t care, High Level or Low Level. See below description: =Don’t Care. This is the default setting, which means all signal will be captured. =High Level. The LA will capture signal that contains High Level. For example: the 4 channel is set as High, then the LA will capture the signal that contains High Level in the 4 channel, the other signal will not be captured.
  • Page 72 Smart+ User’s Manual V1.04.04 Step 1: Select the Protocol Decoders and expand the categories, then select one Protocol Decoders. Also users can input the name of Protocol Decoders in the Find box to find it quickly. Take I2C for example. FM07I4A...
  • Page 73 Smart+ User’s Manual V1.04.04 Step 2: Set parameters needed of the Protocol in the Setting dialog box. Then press Next. FM07I4A...
  • Page 74 Smart+ User’s Manual V1.04.04 Step 3: Finally click the Finish and the I2C Protocol can be used. To build a Bus, first select the Bus type. FM07I4A...
  • Page 75 Smart+ User’s Manual V1.04.04 Step 1: Click Next to enter into the following interface. FM07I4A...
  • Page 76 Smart+ User’s Manual V1.04.04 Step 2. users should select a channel in the left box firstly, then click to move it to the right box, click OK to confirm, then the selected channel is added. Select the channel in the right box and click to delete it.
  • Page 77 Smart+ User’s Manual V1.04.04 Step 3: Click “Advanced Settings…” to set Chip Select or Latch Settings. For some models, Latch function needs to be paid to use, see below image. FM07I4A...
  • Page 78 Smart+ User’s Manual V1.04.04 Clicking “Purchase” would pop up the purchase dialog box, in which click “Purchase” to login ZPP Store to purchase this function. Step 4: The channels included in the Bus can’t do CS setting. After CS is activated, select one channel in the left box and click to move it to the right box, then it can be set as High Level or Low Level.
  • Page 79 Smart+ User’s Manual V1.04.04 Step 5: In the end click Finish, then the Bus is build. FM07I4A...
  • Page 80 Smart+ User’s Manual V1.04.04 Step 6: See above image, Bus 0 includes A0-A1, A3 in low level is the CS channel, the Latch is set as sampling at Rising Edge in A0 channel. To add a channel, firstly select the Channel type. FM07I4A...
  • Page 81 Smart+ User’s Manual V1.04.04 Step 1. Click the Next to enter into the following interface. FM07I4A...
  • Page 82 Smart+ User’s Manual V1.04.04 Step 2. In the Add Channel dialog box, users should select one channel in the left box firstly, then click to move it to the right box, click OK to confirm, then the selected channel is added. Select the channel in the right box and click to delete.
  • Page 83 Smart+ User’s Manual V1.04.04 Step 3. Channel A0, A1 and A2 are added. Click Next to enter into the following interface. FM07I4A...
  • Page 84: Connect Multiple Smart

    Smart+ User’s Manual V1.04.04 Step 4. Click Finish to confirm adding A0, A1 and A2. upgraded. 4.11 Connect Multiple smart+ For Logic Analyzers with the same model, users can connect their hardware and make them work together by using the software, so as to enhance the logic analysis capability, which represented by increased RAM size and channel quantity.
  • Page 85 Smart+ User’s Manual V1.04.04 Activate Stack: It is not selected by default. Stack Type: Select memory stack or channel stack for LAs. Device: Show the connected LAs and their S/N. Master is the LA connecting with the software, and Slave is the LA for stacking.
  • Page 86: Connect To Dso

    Smart+ User’s Manual V1.04.04 4.12 Connect to DSO Note: To use the stack function of LA and oscilloscope, if the oscilloscope is not made by Zeroplus, users need to install the special connection software of oscilloscope manufacturer. ■ If Tektronix oscilloscope is used for stacking, please download the later version than TEKVISA CONNECTIVITY SOFTWARE V3.3.4(included) from Tektronix Website.
  • Page 87 Smart+ User’s Manual V1.04.04 (2) Slave—Master a) Oscilloscope is the Master, LA is the Slave. The Trigger Out of oscilloscope connects with the Trigger In of LA. The LA triggers externally. After triggers, the oscilloscope will notify the LA to capture data. b) Oscilloscope is the Master, LA is the Slave.
  • Page 88 Smart+ User’s Manual V1.04.04 4.12.2 Operating Instruction Resolution: Users can select 3V/Div,2V/Div, 1V/Div, 500mV/Div,200mV/Div, 100mV/Div, 50mV/Div, 20mV/Div, 5mV/Div and 2mV/Div. Display Options: Users can select DS0_CH1, DS0_CH2,DS0_CH2 and DS0_CH4. The captured waveform can be simulated in the waveform view area of LA. Users also can click the Color button to change the channel’s color. If the “Show display inputs only”...
  • Page 89 Smart+ User’s Manual V1.04.04 Oscilloscope Brand: Users can select the oscilloscope brand to stack. For example: Tektronix. Click Connect button to show the oscilloscope model; None will be showed in disconnection condition. Connect Mode: Users can select USB, TCP/IP or Auto to connect. If the oscilloscope connects with the LA by USB, then select USB;...
  • Page 90: Noise Filter Setup

    Smart+ User’s Manual V1.04.04 the main program. The options below Stack Parameters are disabled if the oscilloscope is disconnected. Channel DSO_CH1 and DSO_CH2 of LA connect with channel A0 and A1 of oscilloscope respectively. Below is the captured waveform. 4.13 Noise Filter Setup After Noise Filter is activated, users can select one channel in the left box, and click to add it into the right box, then this channel can do noise filtering.
  • Page 91: Files Comparison

    Smart+ User’s Manual V1.04.04 4.14 Files Comparison For some models, this function needs to be paid to use, click “Data Contrast” from Data menu, then below purchase dialog box will appear. Click “Purchase” to login ZPP Store to purchase this function. 1Analysis(D)->Files Comparison Files Comparison provides the SDK development packet which can help users make their own Files Comparison port.
  • Page 92 Smart+ User’s Manual V1.04.04 Files: Reference File->Select the basic file. Contrast File->Select the file to compare with the Basic File. When contrasting with None, the LA will capture data for one time automatically and add one file.(Settings subject to the basic file.) Start: Set the contrast beginning point subject to the basic file.
  • Page 93 Smart+ User’s Manual V1.04.04 Execute: Perform contrast to see the result. Previous/Next: Go to the previous/next place where the difference locates. Result: Display the status of channels contrast, PASS means the data in the channel is the same in two files, FAIL means the data is different.
  • Page 94: Math Operation

    Smart+ User’s Manual V1.04.04 PASS means the data in the channel of two files is the same. In the waveform view area, the basic waveform and the contrast waveform will be displayed horizontally, users can drag the slider or roll the mouse wheel to see the differences which are marked by orange wavy line “~~~~~”. 4.15 Math Operation 4.15.1 Boolean Operation Boolean Operation: There are AND, OR, NAND, NOR, XOR, XNOR and NOT to choose.
  • Page 95 Smart+ User’s Manual V1.04.04 4.15.2 Arithmetic Operation Users can select two channels or buses to do mathematical operation of add, subtract, multiply and divide. Bus option is available if two or more buses exist. Output Name: Input the name of operation result. Below is the waveform of doing Add operation for A0 and A1.
  • Page 96: Go To

    Smart+ User’s Manual V1.04.04 4.16 Go To… Go to the needed place quickly. Page(Memory Page): The memory size of each page is 512K. If the data in one single page is larger than 512K, inputting page number in the Go To… dialog box and clicking Goto will go to its relevant position. For example: input 2 in the dialog box, then the second page will be displayed, see below image.
  • Page 97 Smart+ User’s Manual V1.04.04 Bar: Go to the specified Bar, such as A Bar, B Bar……Z Bar. The default is A Bar. If B Bar is selected, it will be displayed in the middle of the screen, see below image. FM07I4A...
  • Page 98 Smart+ User’s Manual V1.04.04 FM07I4A...
  • Page 99: Specific Bus Data Display

    Smart+ User’s Manual V1.04.04 4.17 Specific Bus Data Display Name: The name of the selected Bus. Operator: There are =, !=, In Range and Not In Range to choose. Min: Input the Min. value. Max: Input the Max. value. Color: Select color for the specified data that fitting the Bus condition. Below is an example: Open the “Specific Bus Data Display”...
  • Page 100: Signal Activity

    Smart+ User’s Manual V1.04.04 4.18 Signal Activity Click View(V)Signal Activity Signal Statuses: Display the instant level status of each channel by updating twice per second, and capture with 2K Memory size. It displays the pulse if the signal changes, or judges high level or low level if signal has no change. It is at the top layer after opened, the main program cannot perform any other operation.
  • Page 101 Smart+ User’s Manual V1.04.04 FM07I4A...
  • Page 102: Navigator

    Smart+ User’s Manual V1.04.04 4.19 Navigator The Navigator Window is located under the waveform view area. It displays 768K waveform data of four channels. It is opened by default. The waveform in the waveform area is the waveform frame selected in the Navigator. In the Navigator Window, users can click the left key and drag it to select the waveform randomly.
  • Page 103: Packet List

    Smart+ User’s Manual V1.04.04 4.20 Packet List The Bus Packet List can display one or more Buses/Protocol Analyzers according to their packet order, and display the content of each packet according to its order in the Bus memory. It only can display the packet of Bus/Protocol Analyzer.
  • Page 104 Smart+ User’s Manual V1.04.04 Packet#: The packet order. Name: The packet name. TimeStamp: The packet start point. Data: The data in the packet. Length: The length between the start point and the end point. Settings : Click this button to pop out Bus Packet Settings dialog box. Bus Selection: Select the needed Buses.
  • Page 105 Smart+ User’s Manual V1.04.04 Packet Find : Find particular packet. FM07I4A...
  • Page 106 Smart+ User’s Manual V1.04.04 Input the packet number in the box, such as 6 in the above image, and click , it would be displayed at the top of packet list. Packet data also could be found. For example, input Read in the box and click , the first Read packet would be displayed at the top, click to go to the previous Read packet and...
  • Page 107: Statistic

    Smart+ User’s Manual V1.04.04 4.21 Statistic It is used to count the waveform data of each channel, including Full Period, Positive Period, Negative Period, Conditional Position, Conditional Positive Period, Conditional Negative Period and so on. The statistic range can also be changed.
  • Page 108 Smart+ User’s Manual V1.04.04 Select the parameters to be displayed. Except Probe, all parameters are selected by default. Filter Set conditions to filter the unneeded periods, only the periods that fitting the conditions can be counted. This function is not activated by default Highlight Signals FM07I4A...
  • Page 109 Smart+ User’s Manual V1.04.04 The channels that not fitting the condition will be marked in red. Statistics Range: Right click in the Statistics area and select Statistics Area can pop out this dialog box, users can set the data range that need to be counted.
  • Page 110: Memory View

    Smart+ User’s Manual V1.04.04 Count full periods: The incomplete waveform will be filtered. All: Count the data of all memory pages. 4.22 Memory View Memory View has two modes: Compact View and Complete View. Users can click the right key to switch the mode, it is Compact Mode by default.
  • Page 111 Smart+ User’s Manual V1.04.04 Packet buttons Users can find the first packet, the previous packet, the next packet and the last packet of Protocol Analyzer. The start point of the found packet will be at the central position of the waveform view area and marked by a reaction bar (A Bar by default).
  • Page 112 Smart+ User’s Manual V1.04.04 Show Results : All write data is black against white background in the cells. At the same address, if the read data is different with the write data, then the cell will show error in yellow background, and show the last write data of that address.
  • Page 113: Trace Format

    Smart+ User’s Manual V1.04.04 4.23 Trace Format Users can change the width and color of waveform line, Bus(Protocol Analyzer) outline and analog waveform line. Take A0 as an example, set its width to 3 and color to red, see below image. FM07I4A...
  • Page 114: Protocol Decoder

    Decoder has its individual parameters. Currently the Protocol Decoder supports more than 120 and that are free, ZEROPLUS owns the right to decide the Protocol Decoder is free or not. Users can login our website (http://www.zeroplus.com.tw/) to get latest information about Protocol Decoders, or connect our customer service representatives.
  • Page 115 Smart+ User’s Manual V1.04.04 7-SEGMENT LED JTAG 2.0 PS/2 AC97 KEELOQ Code Hopping PSB Interface AES_EBU PT2262/PT2272 AMD_SVI2 LCD 12864 ARITHMETICAL LOGIC LCD1602 Quad SPI LED Pitch Array RGB Interface LG4572 S/PDIF CAN 2.0B LIN 2.1 S2Cwire/AS2Cwire CCIR656 Line code SAMSUNG K9 (NAND Flash) CMOS IMAGE Low Pin Coun...
  • Page 116 Smart+ User’s Manual V1.04.04 USB PD3.0 HID Over I2C CCIR601 FM07I4A...
  • Page 117: Faq

    Smart+ User’s Manual V1.04.04 5 FAQ 5.1 Hardware 5.2 Software 5.3 Registration 5.4 Technical Information 5.5 Others FM07I4A...
  • Page 118: Hardware

    Yes. But it is better to use the bundled cables to connect the object under test and the Logic Analyzer, to ensure the data accuracy. H02. Does Zeroplus manufacture grippers? How may I purchase grippers? Yes, gripper is one of our products, please contact our sales department for purchasing.
  • Page 119: Software

    Smart+ User’s Manual V1.04.04 Software SW01. The reason for not using compression? A: The signal doesn’t need to be recorded for a long time, or the signal changes frequently. SW02. The reason for using compression? A: To get more memory size or the signal changes very slowly. SW03.
  • Page 120 Smart+ User’s Manual V1.04.04 A. In order to acquire the best waveform from the Logic Analyzer and make the full use of memory, in the Double Mode, filter function can be used but the signal delay is not supported. FM07I4A...
  • Page 121: Registration

    A: In this case, take a picture of the hardware series No. and product model on the back of product, and sent it along with the warranty card to Zeroplus and call us, one representative will be specified to work with you.
  • Page 122: Technical Information

    Smart+ User’s Manual V1.04.04 Technical Information TI01. What is the Logic Analyzer? A: The Logic Analyzer is a tool that captures the digital signal from equipment under test by using clock pulse and displays it, it is like a digital oscilloscope, but only has two voltage levels ( logic status 1 and 0), differing from many voltage levels an oscilloscope has.
  • Page 123 Smart+ User’s Manual V1.04.04 TI09. What is an External Trigger? External Trigger is one signal outside the Logic Analyzer. It is used for the simultaneous testing of 2 test tools. For example, one Logic Analyzer can be started by one signal from another test tool. Or when it is triggered, it can output one signal to another test tool.
  • Page 124: Others

    We are working very hard on producing multilingual information and documentations about the Logic Analyzer. Visit our website for the latest driver, software and manual: http://www.zeroplus.com.tw/logic-analyzer_en/technical_support.php. In the meantime, if any error found in the software, we will update the program immediately for users to correct the error for free.
  • Page 125: Troubleshooting

    Smart+ User’s Manual V1.04.04 6 Troubleshooting When the above dialog box appears, and clicking Retry can’t enter the main program, only Run Demo is available, then follow below steps to check: Check the Power of LA is on or off. Check the USB connector is inserted into the USB interfaces of PC and LA properly or not.
  • Page 126: Appendix

    Smart+ User’s Manual V1.04.04 7 Appendix 7.1 Hot Keys 7.2 Contact Us FM07I4A...
  • Page 127: Hot Keys

    Smart+ User’s Manual V1.04.04 Hot Keys Ctrl+N Create a new file. Ctrl+O Open an exit file. Ctrl+F4 Close the current file. Save the active file under its current name and format. Ctrl+S Ctrl+↑ Open the previous file with same path and name. Ctrl+↓...
  • Page 128 Smart+ User’s Manual V1.04.04 Ctrl+End Go to the last memory page. Page Up Go to the previous visible area. Page Down Go to the next visible area. Home Go to the beginning of the waveform. Go to the end of the waveform. Ctrl+C Copy the selected item(s) in the channel area.
  • Page 129: Contact Us

    Smart+ User’s Manual V1.04.04 Contact Us Contact Us Copyright 1997-2017, ZEROPLUS TECHNOLOGY CO., LTD Headquarter ZEROPLUS TECHNOLOGY CO., LTD. 3F., No.121, Jian Ba Rd., Chung Ho City, Taipei County, R.O.C. Taiwan-Chung Ho City Tel: +886-2-6620-2225 Fax: +886-2-6620-2226 ZIP Code: 23585...
  • Page 130 E-Mail: endless_cn@zeroplus.com.tw kan@zeroplus.com.tw Users can download the newest Software and User Manual. ZEROPLUS is the brand of ZEROPLUS TECHNOLOGY CO., LTD. The other brands and product names are the brands or registered trade marks of individual companies or organizations. FM07I4A...

Table of Contents