Summary of Contents for Bogart Engineering TM-2030

  • Page 2 TriMetric Installation   C  H  B  D  E  A  Negative wires from all loads and charging sources must connect to the load side of the shunt: ‐Inverter  ‐Charge Controller  ‐Alternator  ‐Chassis Ground  Illustra on By   R. Brucker;  Used with Permission   G  F  REQUIRED: 4-Wire Cable and Electrical Shunt...
  • Page 3 Turn off main breaker to battery before attempting installation. Remove all connections from battery negative post. Model TM-2030-RV users: It is necessary to drill a small hole in the plastic enclosure in a location suitable for your installation. The hole must be large enough to accommodate the wires being used.
  • Page 4: Primary System Information

    Primary System Information The Trimetric is compatible with all battery chemistries including lead acid, AGM, Gel, Nickel Iron, Lithium, etc. Note for Lithium batteries: When used with the SC-2030, P8-P21 must be programmed to adhere to strict charging guidelines. Visit bogartengineering.com/support for more information. IMPORTANT! After installation, P1 and P3 must be correctly programmed and full charge criteria (determined by P1 and P2) must be met in order for % Full to display an accurate value.
  • Page 5 Secondary Display Data The first five items in this category are listed in the lower box on the front panel of the TM-2030. Please see SC-2030 User Manual for additional displays. The follow- ing displays will repeat as long as SELECT is held down. Release SELECT when you arrive to the desired display. Push SELECT to move through options.
  • Page 6 P13: Low battery voltage alarm setting: “low threshold volts” (10.0-65.0 V) Default: 10.0 Audible alarm also controlled by P9. P17: Shows how many hours after “now” that daily history data H7, H8 ,H9 will be recorded: (0-24). Default 12 P18: Battery calibration voltage adj. Not recommended unless advised by Bogart Engineering. See TM-2030 User’s Instructions, Section 6.4.
  • Page 7 16 mA with display off. detailed description. Battery capacity programmable 10 to 10,000 Amp-hrs. Dimensions: TM-2030-RV: 4-1/4 high x 3 x 1-3/8 inch depth with 1/2 in. flanges Visit www.bogartengineering/support for more information. TM-2030-A: 4-1/2 x 4-3/4 panel with circuit board 1-1/8 (max)
  • Page 8: System Information

    System Information Parallel Series Series/Parallel Ba ery Type and Connec on    Example: Example: Example: Two 6 volt batteries Two 6 volt Two 6 volt batteries (example: AGM, Series, 12V)  @ 230 AH capacity: batteries @ 230 @ 230 AH capacity: 12V 230 AH AH capacity: 6V 12V 460 AH Total AH Capacity  ...