Stealth STL110 Installation Manual

Stl110 series
Hide thumbs Also See for STL110:

Advertisement

STEALTH
STL110H

Specifications:

Switching Capacity:
Voltage:
Detection Pattern:
Time Adjustment:
Power Consumption:
Surge protection:
UL Listing:
STL110 Installation Manual
STL110
STL110R
8 amps
120 volts
1000 watts Incandescent
500 watts Fluorescent
50' x 110˚
5 seconds to 12 minutes
1 watt
I. E.C. specs
Raintight Photoelectric Switch
STL110HB

Advertisement

loading

Summary of Contents for Stealth STL110

  • Page 1: Specifications

    STEALTH STL110 Installation Manual STL110 STL110HB STL110H STL110R Specifications: Switching Capacity: 8 amps Voltage: 120 volts 1000 watts Incandescent 500 watts Fluorescent Detection Pattern: 50’ x 110˚ Time Adjustment: 5 seconds to 12 minutes Power Consumption: 1 watt Surge protection: I.
  • Page 2: Mounting Plate

    All wiring should comply with local electrical codes and requires a qualified electrician. Metal Mounting The total lighting load connected Plate to Stealth must not exceed 8 amps CU4 EZ Insert (1000 watts incandescent or quartz, Screws Plate close-up 500 watts fluorescent).
  • Page 3 12 minutes. Since the lights are on 5 seconds to 12 minutes. Factory Setting: 5–8 minutes only when needed, and the sensor uses only one watt the Stealth is Sensitivity: Increases or extremely energy efficient. decreases the responsiveness and range of the sensor...
  • Page 4 To reduce coverage tilt the sensor down. 5" 12.7 cm Detection Pattern Stealth STL110 comes with a standard “Double Look Down” Lens. This lens has one “Look Out” zone and two “Look Down” zones, for excellent detection both at long Top View 70ʼ...
  • Page 5 (provid- 3. Bring power leads and sensor kit ed) to the junction box. If you are leads through holes in all gaskets attaching your STL110 kit to a into junction box. surface mount weatherproof box, 4. Strip you must use both gaskets, with "...
  • Page 6: Wiring Diagrams

    Switchplate Label motor loads such as HVAC equip- Switchplate label with ment, kitchen appliances, or garage self-adhesive backing. door openers. The Stealth circuit is surge and transient protected to Attach Stealth operat- IEC specifications. However, if ing instruction label to...
  • Page 7 Walk Test The purpose of the Walk Test is to check and adjust the coverage pattern. Stealth has a 5 minute Test Period which allows the sensor to be aimed and walk tested day or night. If you require 5 more minutes...
  • Page 8 Technical Tips: Lights Do Not Turn Off 1. Make sure that the sensor is 3. Make sure sensor and lights are not in Manual Override Mode. Turn mounted firmly and do not move power OFF for 10 seconds, then even slightly when touched. If they ON Sensor will be in Test Mode for move, tighten all screws.
  • Page 9 Technical Tips: Lights Turn On and Off Inappropriately 1. Make sure the sensor is installed within 20 feet of a road or sidewalk. on its own dedicated circuit, free of Passing cars will activate sensor. motor loads such as HVAC equip- Solution: ment, kitchen appliances or garage WRONG!
  • Page 10 Technical Tips: Lights Do Not Turn On Lights Turn Off Too Quickly 1. Check that lamps and fixtures 1. Check if sensor is being “tricked” work. Compare wiring to the wiring by reflected light. If lights controlled diagram in this manual. Check that by the sensor shine or reflect into the power is on.
  • Page 11 Technical Tips: Range Appears Limited 1. Check that the sensor is level 3. Check that movement is not from side to side and pointed at the directly towards sensor. Sensor area you desire. If unit is tilted, part will see movement across its of the detection zone may be high pattern more quickly.
  • Page 12 Technical Tips: Lights Turn On for Unknown Reasons 1. Lights may turn on occasionally 3. You may not be aware that during rain, snow and windstorms animals have triggered the sensor. because the sensor is detection Check sensor aiming to reduce changes in temperature.
  • Page 13: Limited Warranty

    Limited Warranty Your Stealth will be replaced or If your unit is out of warranty or repaired, at our option, if it proves the damage is unrelated to the to be defective in workmanship or original manufacture, return your materials within ten years from the unit directly to us with a check for date of original purchase.
  • Page 14 Contents of Accessory Kit • Indoor Switchplate Label • 3 Wire Nuts • Crossbar with Green Ground Screw • Hanging Hook • 1/2" Close Up Plugs (3) • Slotted Screws (4) • Finishing Cap • O-ring Gasket • Center Mounting Screw •...
  • Page 15 Easy Installation & Product Help Toll Free Phone Toll Free Fax Fax on Demand Call our friendly experts. Send faxes to RAB Faxed information, 8AM - 6PM ET Mon. - Fri. 24/7. 24/7. 888 RAB-1000 888 RAB-1232 888 RAB-1236 E-mail www.rabweb.com Questions and requests Visit our internet site...