Models; Installation - Husky Flair User Manual

Central vacuum system
Table of Contents

Advertisement

3. MODELS

Fig. 1
Shown: flex, available in low voltage and basic wireless technologies

4. INSTALLATION

POWER UNIT
Fig. 2
Mounting the flair on the wall.
The power unit must be installed in a ventilated area, easily accessible and away from any heat source.
It should also be close to an accessible electrical outlet.
Determine the location of the power unit on the wall; we recommend that the power unit be
1.
fastened at 60" / 1,5m from the ground in order for the dust canister to be readily accessible;
allow 12" / 30cm clearance on all sides of the power unit. When possible, it is advisable to
13 | EN
NOTE
» APPLICABLE TO ALL POWER UNITS: in order to avoid
overheating, we recommend 12in / 30cm clearance all around
the power unit.
install the power unit on a concrete wall in order to minimise the vibrations;
Gypsum wall:
2.
•  Prepare the wall by installing a plywood mounting board (not provided) 16" / 40cm high x
3/4" / 2cm thick and wide enough to be screwed to at least 2 studs;
•  Fasten the mounting bracket to the mounting board with the provided screws;
Concrete wall:
3.
•  Drill the holes with a concrete drill bit;
•  Insert the provided wall anchors into the drilled holes;
•  install the mounting bracket with the provided screws into the anchors;
NOTE
» You can still install a plywood mounting (16" / 40cm x 10" /
25cm x 3/4" / 2cm) board if desired;
» You can use provided screws to fix mounting board on the wall,
but cannot use them for installing the mounting bracket on the
mounting board because of their length. You need to use shorter
screws (not provided).
IMPORTANT
Always use the right type of screws for the surface you are working with (wood,
concrete, metal...)
Insert the power unit bracket into the mounting bracket (Fig. 2).
4.
Insert the PVC pipe into the air intake coupling; DO NOT GLUE!
5.
Connect the controller module as explained in section 6;
6.
Connect the power unit directly into an electrical outlet.
7.
DOC-530

Advertisement

Table of Contents
loading

Table of Contents