WEIGHLOG
E X
-‐
O PERATION Service and Technical Support ........................... Error! Bookmark not defined. Electromagnetic Compatibility (EMC) ........................Error! Bookmark not defined. OVERVIEW ___________________________________________________________ 5 Main components ............................ 5 ...
Page 4
WEIGHLOG
E X
-‐
O PERATION
THE LOADING CYCLE _________________________________________________ 23 Machine Requirements ..........................23 Lifting Procedure ............................23 Dynamic Weighing Mode ..........................24 “Last Bucket”...
WEIGHLOG
E X
-‐
O PERATION Overview The Weighlog Ex is a CAN-based system that measures, displays and records the net weight lifted, based on sensing the lift system hydraulic pressure. Main components Two pressure sensors [1], [2] are installed into the hydraulic lift system, with possibly two more [3], [4] installed on machines fitted with accumulator-assistor cylinders.
WEIGHLOG
E X
-‐
O PERATION
Weighing modes When used dynamically, the pressures are captured through a set weighing zone. The system may also be used in static weighing mode. The boom can either be lifted to a set weighing position where the pressure is captured, or measured constantly in a “live”...
WEIGHLOG
E X
-‐
O PERATION
Chassis Angle Display The instrument can be configured via the ‘Home Screen Functions Setup’ screen in the ‘Calibration’ menu, to display the Chassis angle (Uphill / Downhill) in place of an Information Store.
WEIGHLOG
E X
-‐
O PERATION The Loading Cycle Machine Requirements The accuracy of the system depends to some extent on the following : 1. Operating Temperature : Always allow the machine and the hydraulics to warm up to the normal operating temperature before commencing weighing.
WEIGHLOG
E X
-‐
O PERATION “Last Bucket” Weighing When in either Dynamic or Static weighing mode, if the weight exceeds the target required, the weight display turns RED. Regardless if “Auto Entry” ( ) is enabled, the system does not automatically enter the “last bucket” weight.
WEIGHLOG
E X
-‐
O PERATION
Printing, Data Logging and Transfer Data Transfer Options NOTE: Some options may not apply, depending on the setup of your system. TYPE MODE OPTION PRINTER RS232 SERIAL [OFF] No automatic printout after a load is cleared, but (Normally COM 2) Job Records can be printed manually AUTOMATIC MODE...
WEIGHLOG
E X
-‐
O PERATION Reference Stores and Job Records An incremental Job No. is created automatically for each new loading task. When the button is pressed, A 'Job Record' that includes the Load Data and the Store references, is saved automatically to the database on the SD card, and printed out (if setup to do so).