ZLAN ZLAN8100 User Manual

Gprs dtu data transmission device rs232/485 to gprs solution

Advertisement

Quick Links

ZLAN8100
GPRS DTU Data
Transmission Device
User Manual
RS232/485 To GPRS Solution
Copyright© Shanghai ZLAN Information Technology Co., Ltd.
All right reserved
Document DI: ZL DUI 20140421.1.0
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZLAN8100 and is the answer not in the manual?

Questions and answers

Summary of Contents for ZLAN ZLAN8100

  • Page 1 ZLAN8100 GPRS DTU Data Transmission Device User Manual RS232/485 To GPRS Solution Copyright© Shanghai ZLAN Information Technology Co., Ltd. All right reserved Document DI: ZL DUI 20140421.1.0...
  • Page 2 No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or through information storage and retrieval systems, for any purpose other than for the purchaser’s personal use, without the express written permission of ZLAN information Co., Ltd.
  • Page 3: Table Of Contents

    Contents Summary ..........................4 Feature ............................ 5 Technical Parameter ......................6 Hardware Instruction ......................6 Work Station .......................... 7 Optional Work Station Instruction .................. 8 Normal Working Mode .................... 8 User Configuration Mode ..................9 Enter Configuration Mode ................. 9 Obtain Device Parameters ................
  • Page 4: Summary

    Tel: +86-17321037177 http://www.zlmcu.com 1. Summary ZLAN8100 is a new type GPRS remote wireless data transmission device launched by Shanghai ZLAN, it uses embedded design, with embedded TCP/IP protocol stack, meanwhile use powerful microprocessor chip, combined with built-in watchdog, it has stable and reliable performance.
  • Page 5: Feature

    Finance, GPRS, etc. Typical application connections are shown in FIG. 2. Connect the 232/485 devices on site to ZLAN8100, then connect to the Internet via GPRS network so that the remote data center can be connected to ZLAN8100 GPRS DTU.
  • Page 6: Technical Parameter

    Size: 9.4cm×6.5cm×2.5cm 4. Hardware Instruction The front view of ZLAN8100 DTU is shown as FIG. 1. Installation instructions: Antenna installation, the device antenna interface adopts 50Ω/SMA (female), the external antenna must use the antenna suitable for GPRS work band, if use other antenna that not match, it may influence or even damage the DTU.
  • Page 7: Work Station

    1) Power input, terminal-type, DC9~24V. 2) RS485 signal input. 3) RJ45 interface (for later expanding) 5. Work Station 1) The work mode of ZLAN8100 is mainly divided into normal working mode and user configuration mode. Before normal use of this DTU, users should configure...
  • Page 8: Optional Work Station Instruction

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com ZLAN8100 according to their own needs, and then the DTU can enter the normal mode of work. 2) Normal Working Mode After the initialization phase, DTU will enter the work mode of data transmission. In this mode, the device's serial port will transparently receive and send the user's data.
  • Page 9: User Configuration Mode

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com 2) Data to Trigger Online DTU device will automatically connect to the data center after the device is switched on, and then the DTU will automatically get offline if there is no data from the serial port or data center in a certain time.
  • Page 10: Obtain Device Parameters

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Select the serial number and other parameters unchanged. iii. Charge the device and wait for the Active light on. When the Active light is on, please open the serial port in 2 seconds (click the "open"...
  • Page 11: Landing Device

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com function after the search is completed, so no extra access is needed. 3) Landing Device If you want to set the parameters, you must log in, and the default password is 666666.
  • Page 12: Usage

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Figure 6 Advanced Parameters 7. Usage Figure 7 Network Structure The basic usage method is given here, mainly the parameter configuration of 8100DTU. First is the Server settings, it needs to have a public network IP address. The software on the server opens 4196 (any) listening port and waits for the client's connection request.
  • Page 13 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Figure 8 Setting Destination Address Wait a moment, 8100 will connect to the server.
  • Page 14: Parameter Instruction

    Figure 9 Server Accepting Connection As shown in FIG. 9 the Server accepting the connection, you can see there has the Client connecting in on the report box. After that, the server software and the ZLAN8100 serial port can do data communication.
  • Page 15: Equipment At Instruction

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com 10) Heartbeat Content Heartbeat packet content, every heartbeat interval time, send this data to the Server. 11) Data Bit and Stop Bit The data bit and stop bit in the normal communication of serial port.
  • Page 16: Set Serial Parameters

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Command: ZL+DATAB?\r\n Function: gets the data bit Returns: +DATAB:5/6/7/8\r\n 5) Set Serial Parameters Command: ZL+BAUD=n\r\n Function: set baud rate, n represents the value to be set Returns: +BAUD:n\r\n Command: ZL+CHECKB= N/O/E\r\n...
  • Page 17: Setting Network Parameters

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Returns: +PROTOCOL=TCP/UDP\r\n Command: ZL+PDNS?\r\n Role: gets the DNS server IP address Returns: +PDNS=ip\r\n 7) Setting Network Parameters Command: ZL+PIPADD=ip\r\n Role: sets the destination IP or domain name Returns: +PIPADD=ip\r\n Command: ZL+PPORT=n\r\n...
  • Page 18 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com District, Shanghai, CN Tel: +86-21-64325189 Fax: +86-21-64325200 Web: http://www.zlmcu.com Email: support@zlmcu.com...

Table of Contents