12 Gauge Stranded
Black Conductor
Strain Relief
Aircraft Cable
(Included)
Power Plug
(#ML2000-PP)
PRODUCT INFORMATION
• For accent, decorative, ambient lighting
• 120V AC system for fast and easy installation
• Long life, energy efficient LEDs
• Maximum run: 250 ft
• Can be ordered to specific lengths for easier installation when exact
dimensions are known (Example: 10x10' 6")
• Plug and light system
• Lead wires are typically 6' long
• UV rated with SunLight resistance
• Outdoor and indoor rated
• Wire ratings: 12/2 gage wire 300V 105° C UL Listed
105° C 300V VW-2 outdoor rated
ELECTRICAL
• Standard LEDs available in 1W or 3W. See brochure for details
• Maximum watts per run: 600W at 120V based on 5 amps
Black Medium Base Socket
(Included)
Aircraft Hook
(Included)
Canopy Mesh
(Included)
LED Lamp
(Included)
Mounting Aircraft Cable
(Not Included)
Specify Spacing
Specify Length
CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
info@calilighting.com \ calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
End Cap
(#ML2000-EC)
Socket Detail
6.5"
4.25"
Strain Relief Aircraft Cable
(Included)
INSTALLATION RECOMMENDATIONS
• Determine weight of marketLITE that will be used
• Determine length of marketLITE and multiply by weight
• An engineer must choose the proper aircraft cable to handle the tension,
based on length and weight to prevent product from sagging
• An engineer must determine the strength of the structure where the
Strain Relief Aircraft Cable
cable will attach, based on tension calculation from previous step
(Included)
• If installing on a pole, check with pole manufacturer to confirm the pole
can handle the tension
• marketLITE is hung to the above aircraft cable using the hooks. Secure
hooks to aircraft cable by crimping or using stainless steel tie wrap
• The supplied aircraft cable is designed to prevent strain on the wire
An additional aircraft cable is required to hang marketLITE
INSTALLATION TOOLS REQUIRED
• Electric compound miter saw
• 14.4 to 28 volt cordless drill
• Drill bits - concrete or wood
• Electrical cords
• Safety glasses
• Marker
• Electric hammer drill (optional)
ML2000-CM
8.5"
IMPORTANT
VERIFY CORRECT
LUMINAIRE WAS RECEIVED WITH
CORRECT COLOR TEMPERATURE AND
VOLTAGE. MUST INSTALL FACTORY
PROVIDED END CAPS. REVIEW
INSTALLATION INSTRUCTIONS
BEFORE CUTTING OR INSTALLING.
CALI WILL NOT BE RESPONSIBLE IF
INCORRECT LUMINAIRE IS INSTALLED.
• Phillips bits - sufficient quantity
• Electrical three ways
• Measuring tape
• Chalk line
• Sharp scissors
• Soldering iron with kit
1 of 11
Overview

Advertisement

Table of Contents
loading

Summary of Contents for California Accent Lightning marketLITE ML2000-CM

  • Page 1 marketLITE ™ 1 of 11 ML2000-CM Installation Instructions Overview End Cap Black Medium Base Socket (#ML2000-EC) (Included) Aircraft Hook (Included) 12 Gauge Stranded Socket Detail Black Conductor Strain Relief Aircraft Cable (Included) 8.5” 6.5” Canopy Mesh (Included) LED Lamp (Included) Power Plug (#ML2000-PP) 4.25”...
  • Page 2 marketLITE ™ 2 of 11 ML2000-CM Installation Instructions Overview DIMMING PROTOCOL (LED FORWARD PHASE DIMMING) FEATURES Technical Requirements For Control Equipment (Forward Phase Dimming) APPLICATIONS Indoor and Outdoor Lightstring • Electrical Characteristics - Inductive VOLTAGE 120V • Special Requirements - Symmetric cycles LAMP LED Lamp Included DIMMING...
  • Page 3: Product Care

    marketLITE ™ 3 of 11 ML2000-CM Installation Instructions Product Care Do not bend light string to a diameter of less than 1.5” Do not connect light string to power source while spooled or coiled <1.5” <1.5” Do not penetrate bulbs or wires with any foreign object Do not apply excessive pressure to bulbs <1.5”...
  • Page 4 marketLITE ™ 4 of 11 ML2000-CM Installation Instructions Product Care Do not overlap bulbs, canopies, or cages at any location Do not fold, crease, or twist light string <1.5” Do not install dry location product outdoors Do not cover bulbs or sockets with any material <1.5”...
  • Page 5: Application Guidelines

    marketLITE ™ 5 of 11 ML2000-CM Installation Instructions Application Guidelines ML2000-CM REQUIRES A TEAM EFFORT TO ENSURE SECURE AND CORRECT INSTALLATION Aircraft cable must be mounted prior to attaching light string with bulbs Cable lock Screw in bulb only after entire light string has been mounted onto aircraft cable.
  • Page 6 marketLITE ™ 6 of 11 ML2000-CM Installation Instructions Cable Lock & Mounting Plate Cable Lock Mounting Plate (ML2000-CL-1/8”) (ML2000-MP) Mount eye hook to desired surface. Mount mounting plate to desired surface. TIP: Ensure mounting surface is appropriate and capable of supporting the TIP: Ensure mounting surface is appropriate and capable of supporting the weight of the light fixture.
  • Page 7 marketLITE ™ 7 of 11 ML2000-CM Installation Instructions Step by Step Install aircraft cable. Fully insert wires into end cap. NOTE: See previous page for cable mounting details. TIP: Allow silicone to seep out of end cap for a proper seal. Check the silicone seal for holes or gaps.
  • Page 8 marketLITE ™ 8 of 11 ML2000-CM Installation Instructions Step by Step (cont.) Ω Ω VΩ VΩ Separate wires and strip 1/4” to expose conductor wires. Set voltmeter to AC voltage, then test power source before connecting. TIP: Hot wire has ridges along the jacket. Power source Confirm the correct voltage, depending on...
  • Page 9: Hardwire Connection

    marketLITE ™ 9 of 11 ML2000-CM Installation Instructions Hardwire Connection Dry Location Hardwiring Wet Location Hardwiring Feed wire into junction box and secure with strain relief fitting. Feed wire into weatherproof junction box and secure with weatherproof strain relief fitting. TIP: Leave enough excess wire for feed to junction box to be relaxed.
  • Page 10: Troubleshooting

    marketLITE ™ 10 of 11 ML2000-CM Installation Instructions Troubleshooting TROUBLESHOOT Ensure the lead wire is not too long and wound or coiled. • Do not reset breaker multiple times. • If the lighting is overloaded, the panel breaker will trip, shutting off the lights.
  • Page 11: Maintenance

    marketLITE ™ 11 of 11 ML2000-CM Installation Instructions Maintenance CLEANING MATERIALS FOR LENSES AND EXTRUSIONS The use of solvents and/or cleaners which are not compatible with polycarbonate will result in the softening, crazing, and/or cracking of the plastic part. This is especially true of polycarbonate lamps and mounting bases which may be under stress in their normal applications. COMPATIBLE WITH POLYCARBONATE: •...

Table of Contents