Download Print this page

Philips PDEG Installation Instructions page 2

Dynalite

Advertisement

2
A
Ethernet
RJ45
2
B
Ethernet
RJ45
4
Ethernet
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice – This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the
equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an
experienced radio/TV technician for help. Any modifications not approved by the manufacturer of this device could void the user's authority to operate this device.
Installation of a home and building automation and control system shall comply with HD 60364-4-41. The temperature limits and current-carrying capacities for
the communication wires specified in HD 384.5.523 shall not be exceeded.
This Class B digital apparatus complies with Canadian ICES-003: CAN ICES-3(B)/NMB-3(B). Cet appareil numerique de la classe B est conforme a la norme NMB-
003 du Canada: CAN ICES-3(B)/NMB-3(B).
Do not connect inputs to mains.
Philips Dynalite
www.lighting.philips.com/dynalite
© 2018 Philips Lighting. All rights reserved.
GND
AUX
PDEG
ETHERNET SUPPLY IN
RJ12
DYNET
12/24 VDC
-
+
RS-485 DyNet
12-24 V
GND
AUX
PDEG
ETHERNET SUPPLY IN
DYNET
RJ12
12/24 VDC
-
+
12-24 V
DyNet RS-485
3
< 20 m
SERVICE
12 V
RJ12
24 V
SELV/Class 2
≤ 2 A
3
< 20 m
12 V
24 V
SERVICE
12 V
24 V
SELV/Class 2
5
A
-
+
SHLD
GND
D +
D -
+ V
100 mA
AUX
50 mA
RJ12
RS-485 DyNet Port
IEC Overvoltage Category III
B
-
300 mA
+
250 mA
SHLD
GND
D +
D -
+ V
200 mA
AUX
200 mA
RJ12
RS-485 DyNet Port
IEC Overvoltage Category III
DyNet RS485
Ethernet
µP
RJ45
Ethernet
µP
RJ45

Advertisement