Aidcall Touchsafe Pro J25 User Manual

Wireless nursecall system

Advertisement

Quick Links

Touchsafe® Pro
Wireless Nursecall System 
_________________________________________________________________________________________________ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Aidcall operates a policy of continual product improvement and 
reserves the right to modify the specification of its products. 
  
If any variation to the details in this document are suspected please 
contact Aidcall's Technical Support.
 
 
 
 
 
 
 
Aidcall, a business unit of Legrand Electric Ltd 
 
Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF.  
 
T: +44 (0) 1670 357 431   www.aidcall.co.uk  
________________________________________________________________ 
 
 
CAL001 Daisy Ward 
Bedroom 001 
J25 Pager 
User Guide 
 
Doc No. FM5615 issue A Page 1   

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Touchsafe Pro J25 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aidcall Touchsafe Pro J25

  • Page 1     CAL001 Daisy Ward      Bedroom 001                              Aidcall operates a policy of continual product improvement and  reserves the right to modify the specification of its products.     If any variation to the details in this document are suspected please  contact Aidcall’s Technical Support.                 Aidcall, a business unit of Legrand Electric Ltd    Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF.     T: +44 (0) 1670 357 431   www.aidcall.co.uk   ________________________________________________________________   ...
  • Page 2: Table Of Contents

    CONTENTS        Section  Topic  Page        1  Product Overview  2  2  Important Safety Instructions  3  3  Regulatory Information 4  4  Maintenance & Care  4  5  Pager Features  5  6  Getting Started  5  7  Message Display 6  8  Read Messages  6  9  Delete Messages  6  10  Pager Settings Menu 7  11 ...
  • Page 3: Important Safety Instructions

    2.  IMPORTANT SAFETY INSTRUCTIONS      Read and understand these instructions before use. Keep these instructions for future reference.  Do not disassemble this product or attempt to repair it yourself.     No user serviceable parts inside. Refer all servicing to qualified service personnel.    This product should only be powered by 1 x AA size Alkaline battery.   Under no circumstances should this product be powered from another power source.     Insert the battery in accordance with the polarity symbol inside the battery compartment.   Only use manufacturer approved AA size 1.5V battery as identified in this manual.     Do not expose to direct sunlight.     Do not submerge in water and do not use in damp or humid conditions.    Do not expose to dripping or splashing water. As with any electronic equipment take care not to spill  liquids into any part of the system. Liquids can cause a failure and/or a fire hazard.      Do not drop or expose to high vibration or shock.      Clean with a hard‐surface disinfectant wipe or a damp cloth and a non‐abrasive cleaning product.   Polish with a dry duster. DO NOT use a wet cloth.       Avoid using harsh, abrasive or corrosive cleaning agents or detergents (e.g. scouring powders, bleaches,  polishes, etc.) when cleaning this product.        At the end of its life this product should be disposed of and recycled in accordance with the  environmental regulations. See the Regulatory Information in section 3 below.         ...
  • Page 4: Regulatory Information

    3.  REGULATORY INFORMATION        This symbol on the product indicates it complies with all relevant EU Directives as required by law.  Electro Magnetic Compatibility; EMC 2004/108/EC  Restriction of Hazardous Substances; RoHS 2011/65/EU  A copy of the complete Declaration of Conformity is available from Aidcall.      This symbol on the product indicates it is classed as Electrical or Electronic Equipment and should not be  disposed of with other commercial waste at the end of its working life.    The Waste of Electrical and Electronic Equipment (WEEE) Directive (2012/19/EU) has been put in place  to recycle products using the best available recovery and recycling techniques to minimise impact on the  environment, treat hazardous substances and avoid increasing landfill.    For product disposal please contact your supplier and check the terms and conditions of the purchase  contract and ensure this product is not mixed with other commercial waste for disposal.       This symbol on batteries indicates separate collection. Batteries contain chemicals that can be    hazardous to health and the environment and should not be disposed of in the waste bin.     The EU Directive (2006/6/EC) has been put in place to ensure the safe disposal and recycling of  batteries.            Return used batteries to your supplier or drop‐off at your local municipal waste recycling depot.        NTE E   4. MAINTENANCE & CARE   ...
  • Page 5: Pager Features

    5.  PAGER FEATURES    The key features of the J25 Pager are identified below;                        Aidcall Part No. W07280            27 MAY 2015  2 Line x 18 Character  Internal Beeper     10:48 AM WED  Backlit LCD Display    and Vibrate Alert                Message Read Key  Escape Key     (back to previous menu) ...
  • Page 6: Message Display

    7. MESSAGE DISPLAY     The Pager will display the call type and the unit ID as a 6 character code (e.g. EME038) followed by a text  message to identify the location. Icons along the bottom of the display show the Pager status.      Status Icons          EME038  Daisy Ward    Bedroom  038        STATUS ICONS DISPLAYED HERE                    The example above shows an Emergency Call from unit ID 038 which is in Daisy Ward Bedroom 038.  The first 3 characters (EME for Emergency) identify the alarm type, see below for other alarm types;   CAR038 = Cardiac Call from unit ID 038  CAL038 = Call from unit ID 038  NUR038 = Nurse Present at unit ID 038  ASS038 = Assistance Call from unit ID 038  BED038 = Bed to be Cleaned at unit ID 038  CAN038 = Call Cancelled at unit ID 038    The call event will be displayed for 5 seconds, followed by the time & date for 20 seconds before   returning to the blank ( Pager on) screen. If the call is not accepted within the re‐paging delay      then the call will re‐report. ...
  • Page 7: Pager Settings Menu

    10. PAGER SETTINGS MENU    Press any key to go to the STANDBY SCREEN.  Use the  or  keys to select from the following options;  Select SET ALERT to choose Tone, Vibrate, Tone & Vibrate or Silent  Select TURN OFF to switch the Pager off  Select DATE & TIME to set the correct time & date  Press the          READ key to confirm selection.  Use the  or  keys to modify the options and press the         READ key to enter  The            ESCAPE key takes you back to the STANDBY SCREEN without saving changes.      11. CHECKING THE PAGER SETTINGS    Remove the battery from the Pager, press and hold the           ESCAPE key and re‐insert the battery keeping  it pressed until TEST is displayed on the screen, then release.  Press the         READ key to step through the factory settings; they should be as listed below;     V7.1 (Software Version)  SN: xxxxxxxx (Serial No.)  LCD – all display pixels and icons should illuminate  VIBRATOR – unit should vibrate  LAMP – LCD backlight LED’s should illuminate  BEEP – beeper should sound  ID1: xxxxxxx, ID2: xxxxxxx, ID3: xxxxxxx, ID4: xxxxxxx, ID5: xxxxxxx, ID6: xxxxxxx (6 Site Specific ID’s)  BAUD: 512  RF FREQ: 459.2750    The above will then repeat, press the           ESCAPE key to exit.      12. ASTRA/MAXPAGE PAGER ID’s    If J25 Pagers are being used with an Astra Transmitter then first 4 digits of each ID MUST be 0012; the  remaining 3 digits can be any numbers. With a Maxpage Terminal all 7 digits can be any numbers.        ...
  • Page 8: Individual/Group Pager Id's

    13. INDIVIDUAL/GROUP PAGER ID’s    Each Pager can have an individual code so the user can be notified direct from a Maxpage Terminal plus  group codes so they can be notified of alarm calls in their zone direct from the Nursecall system.    Ward 1  Pager 1   ID    0000101  Individual call to Pager (e.g. from Maxpage Terminal)  Group 1  0000100  General calls for Ward 1  Group 2  0000161  Emergency calls for Wards 1 & 2    Pager 2   ID    0000102  Individual call to Pager (e.g. from Maxpage Terminal)      Group 1  0000100  General calls for Ward 1      Group 2  0000161  Emergency calls for Wards 1 & 2    Ward 2  Pager 1   ID    0000201  Individual call to Pager (e.g. from Maxpage Terminal) ...
  • Page 9: Replacing The Battery

        Push Locking Tab UP             Slide Cover Off        Used batteries must not be disposed of in domestic waste. Do not incinerate or mutilate used  batteries, the chemicals released are corrosive and my cause injury to eyes or skin and may be    toxic if inhaled.    Only replace with Manufacturer Approved battery type:   Energizer Industrial 1.5V AA (LR6) Alkaline   Replacement batteries are available from Aidcall; order Part No. F00614    Observe the battery polarity marking inside the battery compartment.  Take care not to damage the battery contacts when removing or inserting batteries.  Refit the battery compartment cover and power‐up as described in section 6.                             ...
  • Page 10: Specification

    16. SPECIFICATION    Model   J25  Frequency Band  459.2750 MHz  Signalling Protocol  POCSAG  Baud Rate  512 bps  Sensitivity  5uV/m  Display  Backlit 2 Line x 18 Character LCD  Pushbuttons  4 No: Read, Next Message, Previous Message, Escape  Max Message Length  500 Characters No. of Stored Messages  60  Languages  UK, USA, French, German, Italian, Spanish, Russian  Alert Options  Beep, Vibrate, Beep + Vibrate, Silent  Beeper Output Level  80dB @ 30cm No. of Different Beep Patterns  3 with Astra (Ackerman) and 4 with Maxpage (ESPA)  No. of Pagers/Site  Unlimited  No. of CAP Codes (ID’s)  6 No. (7 digit numeric codes)  Factory ID1  ON 1234567 Factory ID2‐ID5  All OFF 1234567  Programming  Manually by hand via LCD, OTA or via Windows & USB interface  Battery Type  1 No. AA size Alkaline  Typical Battery Life ...

Table of Contents